Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Surg Endosc ; 24(10): 2492-501, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20339874

RESUMO

BACKGROUND: The aim of this study was to investigate the use of surgical smoke-producing procedures such as laser ablation or electrosurgery in minimally invasive microendoscopic procedures. This study proposes a technical solution to efficiently remove surgical smoke from very small endoscopic cavities using microports as small as 20 G (0.9 mm) in diameter. METHODS: The experimental laboratory study used small, rigid, transparent plastic cavity models connected with tubes and pressure sensors to establish an endoscopic in vitro laboratory model. A Kalium-Titanyl-Phosphate (KTP) laser with a 0.5-mm fiber optic probe was used to produce smoke from bovine scleral tissue in the cavity. Endoscopic gas insufflation into the model was generated by pressurized air and a microvalve. A laboratory vacuum pump provided smoke and gas suction via a microvalve. A self-built control and steering system was utilized to control intracavital pressure during experimental insufflation and suction. RESULTS: Problems related to smoke-generating processes, such as laser vaporization or electrocautery, in small closed cavities were first analyzed. A theoretical and mechatronic laboratory model was established and tested. Intracavital pressure and gas flow were measured first without and then with smoke generation. A new construction design for the suction tube was proposed due to rapid obstruction by smoke particles. CONCLUSIONS: Surgical smoke evacuation from endoscopic cavities that are as small as 2 cm in diameter via minimally invasive ports as small as 20 G (0.9 mm) in diameter may be safe and efficient if sufficient gas exchange is provided during smoke generation by laser or electrosurgical instruments. However, maintaining a low and constant pressure in the cavity during gas exchange and adopting a special construction design for the suction tube are essential to provide an excellent view during the surgical maneuver and to minimize potential toxic side effects of the smoke.


Assuntos
Eletrocirurgia , Endoscopia/efeitos adversos , Terapia a Laser , Microcirurgia , Modelos Estruturais , Fumaça , Animais , Eletrocirurgia/efeitos adversos , Técnicas In Vitro , Terapia a Laser/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...