1.
Int J Neurosci ; : 1-8, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38060517

RESUMO

CONTEXT: Vascular changes can be a risk factor for recurrent and new events of stroke. However, few information is known regarding the variables related to aortic pulse wave morphology in stroke individuals. OBJECTIVE: To analyze aortic pulse wave morphology (arterial stiffness indices, hemodynamics and vascular variables) and to compare the paretic and non-paretic sides in individuals after chronic stroke. DESIGN: In this cross-sectional study stroke individuals had arterial stiffness indices, hemodynamics and vascular variables assessed with brachial artery oscillometry. T-test (CI95%) was used in order to compare the variables between the paretic and non-paretic sides. RESULTS: Twenty individuals were included, 65% men (60.3 SD 16.7 years). The following variables: (mean difference [CI95%]): coefficient of reflection (-2.33 [-4.60 to -0.07]), peak of ejection wave, P1 (5.32 [2.75 to 7.90] and peak of ejection wave, P2 (6.17 [2.55 to 9.78]), central diastolic blood pressure (mean difference [IC95%]): (-3.75 [-6.09 to -1.40]), central systolic blood pressure (-6.17 [-9.74 to -2.59]), mean arterial pressure (-4.46 [-7.08 to -1.84]), peripheral diastolic blood pressure (-3.48 [-5.94 to -1.02]) and peripheral systolic blood pressure (-5.53 [-9.54 to -1.52]) were higher in paretic than non-paretic side. Hemodynamics parameters were similar in both sides. CONCLUSIONS: In this study we demonstrated, for the first time, that many parameters from aortic pulse wave were higher in paretic compared with non-paretic side in individuals after chronic stroke, suggesting that peripheral vascular changes affect heart-vascular coupling in these individuals.

2.
J Bodyw Mov Ther ; 23(4): 844-849, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31733770

RESUMO

OBJECTIVE: To investigate the concurrent validity of the Modified Sphygmomanometer Test (MST) with fixed stabilization, compared to the portable dynamometer, and to verify its test-retest and inter-raterreliability. METHODS: Methodological study. The muscle strength of the following groups was measured: flexors and extensors of the wrist, of the hip, and of the knee and plantar flexors. The Tycos® aneroid sphygmomanometer and the Microfet 2® dynamometer were used. Stabilization was performed using the Mullingan® belt. Descriptive statistics were performed for characterization of the sample. To determine the validity of the MST with fixed stabilization, comparing it with the portable dynamometer, we investigated the correlation between the measurements obtained with the two instruments using the Pearson correlation coefficient. Intraclass Correlation Coefficient (ICC) was used to investigate inter-examiner and test-retest reliability (α = 0.05). RESULTS: 59 individuals were included (1176 evaluations). A statistically significant correlation of moderate to high magnitude (0.58 ≤ r ≤ 0.81) was observed for concurrent validity of the MST with fixed stabilization versus the portable dynamometer for all muscle groups. Regarding inter-rater reliability, it was observed statistically significant ICC considered excellent to good (0.72 ≤ r ≤ 0.94) for all muscle groups. Regarding test-retest reliability, first evaluator presented good to excellent ICC (0.64 ≤ r ≤ 0.94), while second evaluator presented good to excellent ICC (0.74 ≤ r ≤ 0.96) for all muscle groups. CONCLUSION: The MST with fixed stabilization is valid and reliable for clinical measurement of muscle strength and can overcome previous limitations reported in the literature.


Assuntos
Dinamômetro de Força Muscular , Força Muscular/fisiologia , Músculo Esquelético/fisiologia , Esfigmomanômetros , Adolescente , Adulto , Método Duplo-Cego , Feminino , Humanos , Contração Isométrica/fisiologia , Extremidade Inferior/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Punho/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...