Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39009785

RESUMO

BACKGROUND: Personalized radiofrequency (RF) ablation for paroxysmal atrial fibrillation (PAF), adapting the ablation index (AI) to local left atrial wall thickness (LAWT), proved to be highly efficient maintaining high arrhythmia-free survival rates. However, multicentre data are lacking. This multicentre, prospective, non-randomized study was conducted at 5 tertiary hospitals and sought to assess the safety, efficacy, and reproducibility of the LAWT-guided ablation for PAF. METHODS: Consecutive patients referred for first-time PAF were prospectively enrolled. The LAWT maps were obtained from preprocedural multidetector computed tomography and integrated into the navigation system. AI was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the pulmonary veins (PVs). RESULTS: A total 109 patients (60.1 ± 9.4 years, 64.2% male) were enrolled. Median procedure time was 61.7 min (48.4-83.8), fluoroscopy time was 1.0 min (0.4-3.3), and RF time was 13.9 min (12.3-16.8). Median AI tailored to the local LAWT was 393 (374-412) for the anterior wall and 340 (315-378) for the posterior wall. Right and left PVs first-pass isolation was achieved in 89% and 91.7% of the patients, respectively. At 12-month follow-up, freedom from any atrial arrhythmia was 93.4% (95% CI 88.7-98.1), without differences across centres (P = 0.169). One patient experienced femoral artery pseudoaneurysm, with no other serious procedural-related complication. CONCLUSION: The Ablate-by-LAWT study proved that LAWT-guided PV isolation for PAF is safe, effective, and efficient in a multicentre setting. Twelve-month recurrence-free survival exceeded 90% (NCT04218604).

2.
Cardiology ; 147(4): 436-442, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35661073

RESUMO

PURPOSE: The aim of the study was to investigate the effect of wide area circumferential radiofrequency catheter ablation (WACA) pulmonary vein isolation on left atrium (LA) geometry. METHODS: Seventy-one patients underwent WACA, for recurrent paroxysmal (n = 31) and persistent (n = 40) atrial fibrillation (AF). A three-dimension rotational angiography of the LA was obtained immediately prior to index and repeat procedure. RESULTS: Significant reduction of LA volume (65.6 ± 14 mL/m2 vs. 62.2 ± 15 mL/m2, p < 0.001) and surface (74.4 ± 11.2 vs. 70.4 ± 11.2 cm2/m2, p < 0.001) was noted. LA sphericity increased significantly (82 ± 2% vs. 83 ± 2%, p = 0.004) in all 71 patients. Patients with paroxysmal AF showed significant reduction of LA volume (121.8 ± 25.7 vs. 116 ± 32 mL, p = 0.008) and increase of LA sphericity (82.3 ± 2.1 vs. 83.1 ± 2%, p = 0.009). Patients with persistent AF showed significant decrease of LA volume (133.5 ± 32 vs. 126 ± 32 mL, p = 0.005) and LA surface area (76.3 ± 12.3 vs. 71.8 ± 12.4 cm2/m2, p = 0.005). LA sphericity (82.4 ± 2.8 vs. 83 ± 2.4%, p = ns) remained unchanged. CONCLUSIONS: WACA results into significant reduction of LA volume and surface area. Increased LA sphericity is observed in paroxysmal AF only.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 98(1): E69-E77, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33600069

RESUMO

BACKGROUND: This study sought to evaluate the clinical outcomes of patients treated with magnesium-based bioresorbable scaffolds (MgBRS) in the context of acute coronary syndromes (ACS) at long-term follow-up (24 months). The study also aims to investigate the MgBRS performance by angiography and the healing and bioresorption pattern by optical coherence tomography (OCT) at 18 months. METHODS: Between December 2016 and December 2018, a total of 90 patients admitted for ACS and treated with MgBRS (Magmaris, Biotronik AG, Bülach, Switzerland) were enrolled in a multicenter prospective study. Clinical follow-up was performed in all patients at 24 months and angiographic and OCT follow-up in 51.5% of patients at 18 months. Serial OCT was available in 33 patients (36.7%). RESULTS: At a 2-year follow-up, 88.8% were free of symptoms, no cardiac death was reported, and the device-oriented composite event (DOCE): consisting of cardiac death, target vessel myocardial infarction, and target lesion revascularization (TLR) was 13.3%. Stent thrombosis and TLR were observed in 2.2 and 11.1%, respectively. Binary restenosis was observed in 21.7% of cases and in-stent late lumen loss was 0.61 ± 0.75 mm. By serial OCT imaging, the minimal lumen area was significantly reduced greater than 40% (from 6.12 ± 1.59 to 3.5 ± 1.55 mm2, p < .001). At follow-up, area stenosis was 44.33 ± 23.07% and half of the patients presented indiscernible struts. The principal observed mechanism of restenosis was scaffold collapse. CONCLUSIONS: At long-term follow-up, MgBRS implantation in ACS patients showed a high rate of DOCE, mainly caused by clinically driven TLR. MgBRS restenosis was caused by scaffold collapse in most of the cases.


Assuntos
Síndrome Coronariana Aguda , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Angiografia Coronária , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Sirolimo , Tomografia de Coerência Óptica , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 6(11): 1435-1448, 2020 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-33121673

RESUMO

OBJECTIVES: This study sought to analyze safety and outcomes of ventricular tachycardia (VT) substrate ablation during sinus rhythm (SR), without baseline VT induction. BACKGROUND: Safety and outcomes after scar-related VT ablation during SR are not well known. Hemodynamic instability and need for electrical cardioversion can compromise safety of VT ablation procedures. METHODS: Four hundred twelve consecutive patients with structural heart disease undergoing VT ablation were included in a prospective multicenter registry. Substrate ablation during SR, without baseline VT induction, was the first step of the ablation procedure and the standard protocol. Scar dechanneling was the substrate ablation technique used. VT inducibility was tested after substrate ablation. RESULTS: VT induction protocol was negative after substrate ablation in 289 patients (70.1%), completing the procedure in SR. Procedure-related complication rate was 6.5%, including 1 death (0.2%). Thirty-day mortality after first VT ablation procedure was 1.7%. Overall survival was 95.8% and 88.6% at 1 and 3 years of follow-up, respectively. In a multivariable proportional hazards regression model, age ≥70 years (hazard ratio [HR]: 4.95 [2.59 to 9.47]; p < 0.001), chronic obstructive pulmonary disease (HR: 2.37 [1.24 to 4.52]; p = 0.008), left ventricular ejection fraction <30% (HR: 2.43 [1.37 to 4.33]; p = 0.002), and incomplete substrate ablation (HR: 2.37 [1.24 to 4.52]; p = 0.026) were independent predictors of overall mortality. At 12 months' follow-up, VT-free survival was 82.5% after 1 procedure and 87.8% after n procedures CONCLUSIONS: Substrate ablation during SR avoiding multiple VT induction has low procedure-related complications and low early mortality. Age, chronic obstructive pulmonary disease, and reduced left ventricular ejection fraction, but also incomplete substrate elimination, are predictors of mortality.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Sistema de Registros , Volume Sistólico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Função Ventricular Esquerda
5.
J Interv Card Electrophysiol ; 59(1): 21-27, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31625008

RESUMO

BACKGROUND OR PURPOSE: The purpose of this analysis was to report on efficacy of a standardized workflow for atrial fibrillation (AF) ablation using technology advances such as 3D imaging and contact force sensing in a real-world setting. METHODS: Consecutive AF ablations from 2014 to 2015 at a high-volume site in Belgium were included. The workflow consisted of a pre-specified procedure sequence including 3D modeling followed by radiofrequency encircling of the pulmonary veins (25 W posterior wall, 35 W anterior wall) with a THERMOCOOL SMARTTOUCH® Catheter guided by CARTO VISITAG™ Module (2.5 mm/5 s stability, 50% > 7 g) and ablation index (targets: 550 anterior wall, 400 posterior wall). Efficiency endpoints were procedure time, fluoroscopy time, and radiation dose. The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence. RESULTS: A total of 605 paroxysmal AF (PAF) and 182 persistent AF (PsAF) patients were followed for 436 ± 199 days. Mean procedure times were short (PAF: 96.1 ± 26.2 min; PsAF: 109.2 ± 35.6 min) with most procedures (90.6% PAF; 81.3% PsAF) completed in ≤ 120 min. Minimal fluoroscopy was utilized (PAF: 6.1 ± 3.8 min, 5.9 ± 3.4 Gy*cm2; PsAF: 6.9 ± 4.7 min, 7.4 ± 4.9 Gy*cm2). Freedom from atrial arrhythmia recurrence was higher for PAF than PsAF patients (OR: 2.0, 95% CI: 1.4-2.9, p = 0.0003), but adjusted mean rates were high in both groups (81.0% vs. 67.9%). Rates were adjusted for prior ablation and age (at 65 years). CONCLUSION: AF ablation using a standardized workflow resulted in low procedure times and variability, with minimal fluoroscopy exposure. Long-term freedom from atrial arrhythmia recurrence was high in both PAF and PsAF populations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Desenvolvimento Industrial , Recém-Nascido , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento , Fluxo de Trabalho
6.
J Cardiovasc Electrophysiol ; 30(3): 326-331, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30575165

RESUMO

INTRODUCTION: Ablation without shaft repositioning may make the endoscopic laser ablation system (EAS) more like a single shot approach. We tested the feasibility of wide circumferential ablation (WCA; no carina ablation and no shaft repositioning) in an "open 8" pattern for pulmonary vein isolation (PVI). METHODS AND RESULTS: Forty-eight patients (n = 48, age 64.6 ± 12 years) with paroxysmal and persistent atrial fibrillation (AF) were referred to our center for PVI with the EAS. WCA for the lateral and septal pulmonary veins was attempted in all patients. If not feasible, individual full circular isolation of each pulmonary vein (iPVI) was performed. Additional lesions were applied if acute complete electrical isolation was not achieved on the first encirclement. Any documented episode of AF after a 1-month blanking period was registered as a recurrence. Bilateral WCA was feasible in 21 out of 48 patients (43.8%). Additional lesions for complete electrical isolation after the first-pass ablation were less in WCA compared with iPVI (P = 0.02). WCA was accomplished faster, with less applied energy at both lateral (P < 0.01) and septal side (P < 0.01). The mean follow-up of the patient population was 232 ± 150 days. AF recurrence occurred later in patients treated with WCA (315 ± 124 vs 110 ± 88 days, P = 0.008). CONCLUSIONS: WCA with the EAS is safe, at least moderately feasible and highly effective, if achieved. Compared with iPVI it may be less time consuming, results in less energy application, and suppresses AF more effectively.


Assuntos
Fibrilação Atrial/cirurgia , Endoscopia , Terapia a Laser , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Endoscopia/efeitos adversos , Endoscopia/instrumentação , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/instrumentação , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Artigo em Inglês | MEDLINE | ID: mdl-20879292

RESUMO

This paper presents a new diffeomorphic temporal registration algorithm and its application to motion and strain quantification from a temporal sequence of 3D images. The displacement field is computed by forward eulerian integration of a non-stationary velocity field. The originality of our approach resides in enforcing time consistency by representing the velocity field as a sum of continuous spatiotemporal B-Spline kernels. The accuracy of the developed diffeomorphic technique was first compared to a simple pairwise strategy on synthetic US images with known ground truth motion and with several noise levels, being the proposed algorithm more robust to noise than the pairwise case. Our algorithm was then applied to a database of cardiac 3D+t Ultrasound (US) images of the left ventricle acquired from eight healthy volunteers and three Cardiac Resynchronization Therapy (CRT) patients. On healthy cases, the measured regional strain curves provided uniform strain patterns over all myocardial segments in accordance with clinical literature. On CRT patients, the obtained normalization of the strain pattern after CRT agreed with clinical outcome for the three cases.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Ecocardiografia Tridimensional/métodos , Técnicas de Imagem por Elasticidade/métodos , Coração/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Algoritmos , Módulo de Elasticidade , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Europace ; 11(12): 1675-82, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19880850

RESUMO

AIMS: Some authors recommend avoiding fusion with left ventricular (LV) intrinsic depolarization during cardiac resynchronization therapy (CRT). If fusion is still present during optimized biventricular (Biv) pacing and its long-term effects on the response to CRT are currently unknown. The aim of the study was to analyse the endocardial LV activation pattern induced by echocardiographically optimized Biv pacing and its influence on LV reverse remodelling. METHODS AND RESULTS: Contact electro-anatomical mapping was performed in 15 heart failure (HF) patients with left bundle branch block and echocardiographically optimized CRT (seven ischaemic aetiology, 64 +/- 8 years, three women, New York Heart Association class 3 +/- 0.4, LV ejection fraction 25 +/- 5%). Left ventricular activation maps were performed in sinus rhythm (SR), during DDD right ventricular apical (RVA) and optimized Biv pacing. Fusion with intrinsic rhythm during pacing was considered when LV septal activation was produced at least partially by intrinsic depolarization, when compared with LV activation map during SR. Patients were considered responders to CRT if they had > or =10% reduction in LV end-systolic volume (LVESV) after 6 months of CRT. During SR, the LV breakthrough was mid-septal (n = 12), basal septum (n = 2), and apical (n = 1). During RVA pacing, LV breakthrough shifted apical in all patients. Right ventricular apical/Biv pacing proved fusion with intrinsic depolarization in 8 of 15 patients. The PR interval was shorter in patients with fusion RVA/Biv pacing (164 +/- 24 vs. 234 +/- 55 ms, P = 0.006). There was a trend for shorter LV activation time (LV(at)) in patients with fusion during RVA pacing (87 +/- 33 vs. 113 +/- 21 ms, P = 0.08) as well as during optimized Biv pacing (83 +/- 18 vs. 104 +/- 24 ms, P = 0.07), although LV(at) was similar in SR (100 +/- 22 vs. 106 +/- 20, P = NS). In patients with fusion, 6 months responder rate was significantly higher (100 vs. 28.5%, P < 0.007) as was the degree of LVESV reduction (39 +/- 17 vs. 1.0 +/- 14%, P < 0.001). CONCLUSION: Biventricular pacing with fusion may substantially increase the structural responder rate probably by shortening LV(at).


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Idoso , Bloqueio de Ramo/complicações , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Resultado do Tratamento
10.
Med Image Comput Comput Assist Interv ; 12(Pt 2): 759-66, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20426180

RESUMO

In this paper, we propose a complete framework for the automatic detection and quantification of abnormal heart motion patterns using Statistical Atlases of Motion built from healthy populations. The method is illustrated on CRT patients with identified cardiac dyssynchrony and abnormal septal motion on 2D ultrasound (US) sequences. The use of the 2D US modality guarantees that the temporal resolution of the image sequences is high enough to work under a small displacements hypothesis. Under this assumption, the computed displacement fields can be directly considered as cardiac velocities. Comparison of subjects acquired with different spatiotemporal resolutions implies the reorientation and temporal normalization of velocity fields in a common space of coordinates. Statistics are then performed on the reoriented vector fields. Results show the ability of the method to correctly detect abnormal motion patterns and quantify their distance to normality. The use of local p-values for quantifying abnormal motion patterns is believed to be a promising strategy for computing new markers of cardiac dyssynchrony for better characterizing CRT candidates.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial/métodos , Ecocardiografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/prevenção & controle , Simulação por Computador , Humanos , Aumento da Imagem/métodos , Modelos Cardiovasculares , Modelos Estatísticos , Movimento (Física) , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...