Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hazard Mater ; 170(2-3): 855-60, 2009 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-19525063

RESUMO

Lead (Pb) contamination in the black paper that recovers intraoral films (BKP) has been investigated. BKP samples were collected from the Radiology Clinics of the Dental School of Ribeirão Preto, University of São Paulo, Brazil. For sake of comparison, four different methods were used. The results revealed the presence of high lead levels, well above the maximum limit allowed by the legislation. Pb contamination levels achieved after the following treatments: paper digestion in nitric acid, microwave treatment, DIN38414-54 method and TCLP method were 997 microg g(-1), 189 microg g(-1), 20.8 microg g(-1), and 54.0 microg g(-1), respectively. Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS) were employed for lead determination according to the protocols of the applied methods. Lead contamination in used BKP was confirmed by scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDS). All the SEM imaging was carried out in the secondary electron mode (SE) and backscattered-electron mode (QBSD) following punctual X-ray fluorescence spectra. Soil contamination derived from this product revealed the urgent need of addressing this problem. These elevated Pb levels, show that a preliminary treatment of BKP is mandatory before it is disposed into the common trash. The high lead content of this material makes its direct dumping into the environment unwise.


Assuntos
Materiais Dentários/análise , Poluentes Ambientais/análise , Poluição Ambiental/análise , Chumbo/análise , Eliminação de Resíduos de Serviços de Saúde/métodos , Papel , Filme para Raios X , Ácidos , Espectrometria de Massas , Metais/isolamento & purificação , Microscopia Eletrônica de Varredura , Micro-Ondas , Solubilidade , Espectrofotometria Atômica , Poluentes Químicos da Água/análise , Abastecimento de Água/análise
2.
Photomed Laser Surg ; 25(4): 281-6, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17803385

RESUMO

OBJECTIVE: The aim of this study was to evaluate in vitro the pulp thermal alterations during class V cavity preparations using the Er:YAG laser and high-speed water flow. MATERIALS AND METHODS: Forty human teeth were selected and prepared for the thermocouple adaptation in the pulp chamber. The specimens were assigned to four groups: (1) laser 300 mJ/3 Hz, (2) laser 300 mJ/4 Hz, (3) high-speed 9 mL/min water flow, and (4) high-speed 100 mL/min water flow. The temperature was measured before the beginning and at the end of the preparation, as well as during the procedures. The groups were analyzed by scanning electron microscopy. RESULT: Data analysis disclosed temperature reduction at high-speed drilling with the high-speed total water flow group, and these values were statistically different from the other groups. The results of the 9-mL/min water flow group were similar to those of the 300-mJ/3-Hz group and different from the 300-mJ/4-Hz laser group. CONCLUSION: The laser promoted a greater increase in temperature only when compared with high-speed handpiece and water flow rate of 100 mL/min.


Assuntos
Temperatura Corporal/efeitos da radiação , Preparo da Cavidade Dentária/instrumentação , Polpa Dentária/efeitos da radiação , Terapia a Laser , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...