Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Braz Oral Res ; 31: e37, 2017 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-28591236

RESUMO

The characteristics of non-obese patients with mild to moderate Obstructive Sleep Apnea Syndrome (OSAS) who will present with a good response to Mandibular Repositioning Appliance (MRA) treatment have not yet been well established in the literature. The aim of this study is to assess whether polysomnographic (PSG), demographic, anthropometric, cephalometric, and otorhinolaryngological parameters predict MRA success in the treatment of OSAS. Forty (40) males with mild and moderate OSAS were assessed pretreatment and 2-months post-treatment after wearing an MRA. Demographic, anthropometric, otorhinolaryngological (ENT), cephalometric, and polysomnographic parameters, including continuous positive airway pressure (CPAP) titrated pressure, dental models, Epworth Sleepiness Scale, quality of life (Short Form SF-36), and mood state (Profile of Mood States - POMS), were assessed. The responders exhibited fewer oropharyngeal alterations, increased upper pharyngeal space, reduced lower airway space, and increased mandibular intercanine width, and they had milder disease. Nevertheless, no predictive factors of MRA success could be found. MRA was more successful among men with a more pervious airway, a larger interdental width and milder OSAS. However, a combined [1] functional and structural assessment is needed to successfully predict the [2] effectiveness of MRA treatment of OSA.


Assuntos
Avanço Mandibular/instrumentação , Avanço Mandibular/métodos , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Pontos de Referência Anatômicos , Índice de Massa Corporal , Cefalometria , Pressão Positiva Contínua nas Vias Aéreas/métodos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Aparelhos Ortodônticos , Faringe , Polissonografia , Estudos Prospectivos , Qualidade de Vida , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Risco , Estatísticas não Paramétricas , Inquéritos e Questionários , Resultado do Tratamento
2.
J Appl Oral Sci ; 25(1): 61-68, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28198977

RESUMO

OBJECTIVE: The aim of this study was to assess the performance of resin cements when different curing modes are used, by evaluating the degree of conversion and bond strength to a ceramic substrate. MATERIAL AND METHODS: Three resin cements were evaluated, two dual-cured (Variolink II and RelyX ARC) and one light-cured (Variolink Veneer). The dual-cured resin cements were tested by using the dual activation mode (base and catalyst) and light-activation mode (base paste only). For degree of conversion (DC) (n=5), a 1.0 mm thick feldspathic ceramic disc was placed over the resin cement specimens and the set was light activated with a QTH unit. After 24 h storage, the DC was measured with Fourier transform infrared spectroscopy (FTIR). For microshear bond strength testing, five feldspathic ceramic discs were submitted to surface treatment, and three cylindrical resin cement specimens were bonded to each ceramic surface according to the experimental groups. After 24 h, microshear bond testing was performed at 0.5 mm/min crosshead speed until the failure. Data were submitted to one-way ANOVA followed by Tukey test (p<0.05). Scanning electron microscopy (SEM) was used for classifying the failure modes. RESULTS: Higher DC and bond strength values were shown by the resin cements cured by using the dual activation mode. The Variolink II group presented higher DC and bond strength values when using light-activation only when compared with the Variolink Veneer group. CONCLUSION: The base paste of dual-cured resin cements in light-activation mode can be used for bonding translucent ceramic restorations of up to or less than 1.0 mm thick.


Assuntos
Silicatos de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Cerâmica/química , Cura Luminosa de Adesivos Dentários/métodos , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Compostos de Potássio/química , Cimentos de Resina/química , Análise de Variância , Lâmpadas de Polimerização Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Processos Fotoquímicos , Polimerização , Valores de Referência , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Propriedades de Superfície , Fatores de Tempo
3.
Int J Oral Maxillofac Implants ; 27(4): 793-800, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22848880

RESUMO

PURPOSE: This study sought to evaluate the influence of methodologic aspects on variations in the findings of in vitro microleakage studies of the implant-abutment interface. MATERIALS AND METHODS: The MEDLINE, EMBASE, and Cochrane Library databases were consulted for in vitro studies published between 1990 and August 2011. Date from the studies that met the inclusion and exclusion criteria were arranged in tables and subjected to descriptive analysis. RESULTS: Twenty-one studies were found to be eligible for the analysis after application of the inclusion/exclusion criteria. Sixteen studies used bacteria (76.2%), one used a bacterial toxin (4.76%), one used saliva (4.76%), two employed dyes (9.52%), and one used a combination of dyes and bacteria (4.76%). Eight studies evaluated microleakage from the inner portion of the implant to the external portion (38.1%) and nine examined the reverse (42.85%), while four studies investigated the relationship between them (19.05%). The volume inoculated inside the implants ranged from 0.1 to 5.0 mL. The bacterial concentrations used in the tests ranged from 2.41 x 106 to 8 x 108 colony-forming units/mL. Oral bacterial flora; mixtures of bacteria, toluidine blue, and gentian violet; and lipopolysaccharide of Salmonella enterica bacterial toxins were used. The monitoring period of test results ranged from 24 hours to 11 weeks for bacteria, 5 minutes to 7 days for dye, and 7 days for bacterial toxins. In four studies, microleakage was correlated with the size of the implant-abutment microgap. The external-hexagon implant configuration showed the greatest microleakage, followed by internal-trilobe, internal-hexagon, and internal-taper configurations. CONCLUSION: The lack of standardization hinderd comparisons of the studies and could explain the divergent results. It is suggested for future studies that special emphasis be placed upon inoculation and analysis of the specific volume for each system, lower concentrations of inoculated bacterial suspensions, and shorter follow-up time when using bacteria.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Implantes Dentários , Infiltração Dentária/diagnóstico , Carga Bacteriana/métodos , Corantes , Implantes Dentários/microbiologia , Infiltração Dentária/microbiologia , Violeta Genciana , Humanos , Polissacarídeos Bacterianos , Saliva , Salmonella enterica , Fatores de Tempo , Cloreto de Tolônio
4.
J Contemp Dent Pract ; 8(6): 89-95, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17846676

RESUMO

AIM: The aim of this article is to describe a step-by-step protocol for emergency care of a patient with a dentoalveolar injury in the anterior region of the mouth as well as the fabrication of a mouthguard to prevent future trauma. BACKGROUND: Dental trauma is one of the most serious oral health problems in active children and adolescents. Care of traumatized patients requires immediate initial emergency treatment followed by integrated procedures to restore damaged oral structures along with a subsequent trauma prevention strategy. Dentoalveolar injuries in the anterior region of the mouth are often characterized by tooth avulsion and coronal fracture. They are managed using procedures such as dental splinting, endodontic therapy with its unique characteristics, and restorative techniques to re-establish function and esthetics as well as protective mouthguards. REPORT: A 16-year-old male presented with avulsion of his maxillary central incisors as a result of a direct, unintentional impact with an opponent during a basketball game. The teeth had been stored in physiological serum immediately following the injury and the patient received immediate care. On clinical examination, the right central incisor was fractured at the incisal third of the crown but no bone fractures were found. The teeth were reimplanted and splinted. The fractured right central incisor was restored following endodontic treatment and a mouthguard was fabricated for the patient. SUMMARY: The dentist must be knowledgeable about the most efficient and suitable treatment for each traumatic scenario in order to provide appropriate care for dental injuries. Coordinated multi-disciplinary action is fundamental in the successful treatment of these injuries. The dental mouthguard is an effective device for protecting the teeth and supportive structures during physical activities and must be part of the protective equipment used by athletes. It is the responsibility of the dental professional to make parents, trainers, and athletic associations aware of the risks associated with physical activities without orofacial protection; this should encourage the proper use of all protective devices to prevent dentoalveolar injuries that compromise oral functions, esthetics, and increase the cost of healthcare.


Assuntos
Restauração Dentária Permanente/métodos , Incisivo/lesões , Protetores Bucais , Avulsão Dentária/cirurgia , Fraturas dos Dentes/terapia , Reimplante Dentário , Adolescente , Traumatismos em Atletas/prevenção & controle , Basquetebol/lesões , Resinas Compostas , Colagem Dentária , Tratamento de Emergência , Humanos , Masculino , Maxila , Contenções Periodontais , Tratamento do Canal Radicular , Equipamentos Esportivos , Avulsão Dentária/prevenção & controle , Fraturas dos Dentes/prevenção & controle
5.
J Prosthet Dent ; 95(2): 161-4, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16473091

RESUMO

This article describes a technique for replacement of a lost implant. The procedure involves the use of templates, drill guides, and drills of the system to replace a 4.5-mm-wide lost implant with a 5.0-mm-wide implant. The surgical procedure was simplified to optimize the healing process and to be more comfortable for the patient. The accuracy of the templates and guides allowed for ideal position of the implant and the immediate use of the original fixed implant-supported prosthesis.


Assuntos
Implantação Dentária Endóssea/instrumentação , Implantação Dentária Endóssea/métodos , Implantes Dentários , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Prótese Total Imediata , Prótese Total Inferior , Remoção de Dispositivo , Humanos , Arcada Edêntula/reabilitação , Mandíbula/cirurgia , Modelos Anatômicos , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...