Hip Int ; 21(2): 270-2, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21484742

RESUMO

We present the case of a 55-year-old woman who sustained a left femoral neck fracture which was managed by insertion of a dynamic hip screw. Six hours after surgery, distension appeared in the left lower quadrant of her abdomen associated with a decline in haemoglobin concentration and clinical signs of ongoing bleeding. Computed tomography showed a left retroperitoneal mass without concomitant extravasation of contrast material. Exploratory laparotomy revealed a damaged left obturator artery with a large haematoma in its vicinity. After arterial ligation and retroperitoneal space decompression her postoperative course was uneventful. Reviewing intraoperative C arm images a 0.8 cm protrusion of the threaded guide wire was identified as the cause of obturator artery damage.


Assuntos
Artéria Femoral/lesões , Fixação de Fratura/efeitos adversos , Fraturas do Quadril/cirurgia , Complicações Pós-Operatórias , Lesões do Sistema Vascular/etiologia , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Procedimentos Cirúrgicos Vasculares/métodos , Lesões do Sistema Vascular/cirurgia