Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 34(4): 2334-2351, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37672051

RESUMO

OBJECTIVES: Position- and posture-dependent deformation of the vascular system is a relatively unexplored field. The goal of this scoping review was to create an overview of existing vascular imaging modalities in different body positions and postures and address the subsequent changes in vascular anatomy. METHODS: Scopus, Medline, and Cochrane were searched for literature published between January 1, 2000, and June 30, 2022, incorporating the following categories: image modality, anatomy, orientation, and outcomes. RESULTS: Out of 2446 screened articles, we included 108. The majority of papers used ultrasound (US, n = 74) in different body positions and postures with diameter and cross-sectional area (CSA) as outcome measures. Magnetic resonance imaging (n = 22) and computed tomography (n = 8) were less frequently used but allowed for investigation of other geometrical measures such as vessel curvature and length. The venous system proved more sensitive to postural changes than the arterial system, which was seen as increasing diameters of veins below the level of the heart when going from supine to prone to standing positions, and vice versa. CONCLUSIONS: The influence of body positions and postures on vasculature was predominantly explored with US for vessel diameter and CSA. Posture-induced deformation and additional geometrical features that may be of interest for the (endovascular) treatment of vascular pathologies have been limitedly reported, such as length and curvature of an atherosclerotic popliteal artery during bending of the knee after stent placement. The most important clinical implications of positional changes are found in diagnosis, surgical planning, and follow-up after stent placement. CLINICAL RELEVANCE STATEMENT: This scoping review presents the current state and opportunities of position- and posture-dependent imaging of vascular structures using various imaging modalities that are relevant in the fields of clinical diagnosis, surgical planning, and follow-up after stent placement. KEY POINTS: • The influence of body positions and postures on the vasculature was predominantly investigated with US for vessel diameter and cross-sectional area. • Research into geometrical deformation, such as vessel length and curvature adaptation, that may be of interest for the (endovascular) treatment of vascular pathologies is limited in different positions and postures. • The most important clinical implications of postural changes are found in diagnosis, surgical planning, and follow-up after stent placement.


Assuntos
Postura , Tomografia Computadorizada por Raios X , Humanos , Imageamento por Ressonância Magnética/métodos , Artéria Poplítea
2.
J Endovasc Ther ; : 15266028231209929, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37933525

RESUMO

OBJECTIVE: The performance of fenestrated endovascular aortic aneurysm repair (FEVAR) may be compromised by complications related to the dynamic vascular environment. The aim of this study was to analyze the behavior of FEVAR bridging stent configurations during the cardiac cycle and during follow-up to improve our understanding on treatment durability. DESIGN: Twenty-one patients presenting with complex abdominal aortic aneurysms (AAAs; 9 juxtarenal/6 pararenal/3 paravisceral/1 thoracoabdominal aortic aneurysm type IV), treated with a fenestrated Anaconda (Terumo Aortic, Inchinnan, Scotland, UK) with Advanta V12 bridging stents (Getinge, Merrimack, NH, USA), were prospectively enrolled in a multicenter observational cohort study and underwent electrocardiogram (ECG)-gated computed tomographic angiography (CTA) preoperatively, at discharge, 7-week, and 12-month follow-ups. METHODS: Fenestrated endovascular aortic aneurysm repair stability was assessed considering the following variables: branch angle as the angle between the aorta and the target artery, end-stent angle as the angle between the end of the bridging stent and the native artery downstream from it, curvature and tortuosity index (TI) to describe the bending of the target artery. Body-bridging stent stability was assessed considering bridging stent flare lengths, the distances between the proximal sealing stent-ring and fenestrations and the distance between the fenestration and first apposition in the target artery. RESULTS: Renal branch angles significantly increased after FEVAR toward a perpendicular position (right renal artery from median 60.9°, inter quartile range [IQR]=44.2-84.9° preoperatively to 94.4°, IQR=72.6-99.8°, p=0.001 at 12-month follow-up; left renal artery [LRA], from 63.7°, IQR=55.0-73.0° to 94.3°, IQR=68.2-105.6°, p<0.001), while visceral branch angles did not. The mean dynamic curvature only decreased for the LRA from preoperative (3.0, IQR=2.2-3.8 m-1) to 12-month follow-up (1.9, IQR=1.4-2.6 m-1, p=0.027). The remaining investigated variables did not seem to show any changes over time in this cohort. CONCLUSIONS: Fenestrated endovascular aortic aneurysm repair for complex AAAs using the Anaconda fenestrated stent-graft and balloon-expandable Advanta V12 bridging stents demonstrated stable configurations up to 12-month follow-up, except for increasing renal branch angles toward perpendicular orientation to the aorta, yet without apparent clinical consequences in this cohort. CLINICAL IMPACT: This study provides detailed information on the cardiac-pulsatility-induced (dynamic) and longitudinal geometry deformations of the target arteries and bridging stents after fenestrated endovascular aortic aneurysm repair (FEVAR) up to 12-month follow-up. The configuration demonstrated limited dynamic and longitudinal deformations in terms of branch angle, end-stent angle, curvature, and tortuosity index (TI), except for the increasing renal branch angles that go toward a perpendicular orientation to the aorta. Overall, the results suggest that the investigated FEVAR configurations are stable and durable, though careful consideration of increasing renal branch angles and significant geometry alterations is advised.

3.
JVS Vasc Sci ; 4: 100131, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38033397

RESUMO

Objective: The goal of this study was to determine to what extent aortic stent graft motion quantification is comparable between electrocardiogram (ECG)-gated computed tomography (CT) scans with reconstructions into 8 and 10 cardiac phases on CT scanners from two different vendors. Methods: An experimental setup that induces motion of an aortic stent graft, according to a predefined aortic blood pressure wave, was placed in two CT scanners of different vendors. The stent graft motion was captured using an ECG-gated CT technique and quantified using dedicated analysis algorithms. The calculated motion amplitudes and total traveled path lengths of stent segmentations were compared between scans reconstructed into 8 and 10 phases and between the scanners, after validation with sensor measurements and repeated measurements. Results: No difference in motion amplitudes in z-direction (craniocaudal direction) was observed between the reconstructions into 8 and 10 phases (0.02 mm; 95% confidence interval [CI], -0.01 to 0.05 mm; P = .358). The z-amplitudes differed by 0.04 mm (95% CI, 0.01-0.07 mm; P = .003) between the different CT scanners. Path lengths differed 0.07 mm (95% CI, 0.01-to 0.13 mm; P = .013) between the reconstructions into 8 and 10 phases and 0.13 mm (95% CI, 0.06-0.17 mm; P < .001) between the different scanners. Conclusions: The motion amplitudes can accurately be compared between 8 and 10 phases and between the two scanners, without differences larger than the voxel size of 0.3 × 0.3 × 0.5 mm. Clinical motion analysis results of different ECG-gated CT scans and CT scanners can be compared up to the accuracy of the CT scan.

4.
Diagnostics (Basel) ; 13(3)2023 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-36766601

RESUMO

To what extent the stentgraft design of iliac branch devices (IBDs) relates to dynamic deformation is currently unknown. Therefore, this study aimed to quantify and compare displacement and geometry changes during the cardiac cycle of two common IBDs. This paper presents a two-center trial with patients treated with a Zenith bifurcated iliac side (ZBIS) or Gore iliac branch endoprosthesis (IBE). All patients underwent a retrospective electrocardiogram (ECG)-gated computed tomographic angiography (CTA) during follow-up. Cardiac-pulsatility-induced displacement was quantified for the following locations: (neo) bifurcation of the aorta, IBD flow divider, distal markers of the internal iliac artery (IIA) component and first IIA bifurcation. Geometrical parameters (length, tortuosity index, curvature and torsion) were quantified over centerlines. Displacement was more pronounced for the IBE than the ZBIS, e.g., craniocaudal displacement of 0.91 mm (0.91-1.13 mm) vs. 0.57 mm (0.40-0.75 mm, p = 0.004), respectively. The IBDs demonstrated similar geometrical parameters in the neo-common iliac artery and distal IIA, except for the larger dynamic curvature and torsion of the distal IIA in IBEs. The IBEs showed more dynamic length and curvature change compared to the ZBIS in the stented IIA. The IIA trajectory showed more pronounced deformation during the cardiac cycle after placement of an IBE than a ZBIS, suggesting the IBE is more conformable than the ZBIS.

5.
J Endovasc Ther ; 30(4): 510-519, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35352980

RESUMO

The Relay®Branch stent-graft (Terumo Aortic, Sunrise, FL, USA) offers a custom-made endovascular solution for complex aortic arch pathologies. In this technical note, a modified electrocardiography (ECG)-gated computed tomography (CT)-based algorithm was applied to quantify cardiac-pulsatility-induced changes of the aortic arch geometry and motion before and after double-branched endovascular repair (bTEVAR) of an aortic arch aneurysm. This software algorithm has the potential to provide novel and clinically relevant insights in the influence of bTEVAR on aortic anatomy, arterial compliance, and stent-graft dynamics.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Stents , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Desenho de Prótese , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Estudos Retrospectivos
6.
J Endovasc Ther ; 30(6): 904-919, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35786215

RESUMO

PURPOSE: Thromboembolic events (TE), including limb graft occlusion (LGO) and distal limb embolization (DLE), are common complications after endovascular aneurysm repair (EVAR). The aim of this study was to find predictors for TE in patients treated with the Anaconda stent-graft for infrarenal aneurysms. MATERIALS AND METHODS: Geometrical and anatomical variables were retrospectively analyzed in a consecutive Anaconda cohort. Pre- and postoperative CT scans were used to derive geometrical parameters length, curvature, torsion, and tortuosity index (TI) from the center lumen lines (CLLs). Limb characteristics, pre-to-post EVAR and mid-term-follow-up changes in the parameters were evaluated for their predictive value for TE. RESULTS: Eighty-four patients (mean age 74±8.3 years, 74 men) were enrolled. The risk of TE was lowered with pre-to-post implant decreasing TI (steps of 0.05: OR: 1.30, 95% CI: 1.01-1.66, p=0.04), pre-to-post implant decreasing mean curvature (OR: 1.08, 95% CI: 1.01-1.16, p=0.03), and a larger degree of circumferential common iliac artery (CIA) calcification (OR: 0.98, 95% CI: 0.97-1.00, p=0.03). The only LGO predictor was the caudal relocation of maximal curvature after EVAR (OR: 1.01, 95% CI: 1.00-1.01, p=0.04). Preventors of DLE were CIA diameter (OR: 0.87, 95% CI: 0.76-0.99, p=0.04), circumferential CIA calcification (OR: 0.97, 95% CI: 0.95-1.00, p=0.03), mean and maximal curvature of the preoperative aortoiliac trajectory (OR: 0.86, 95% CI: 0.79-0.94, p<0.01 and OR: 0.97, 95% CI: 0.95-1.00, p=0.03, respectively) and pre-to-postoperative decrease in mean curvature (OR: 1.11, 95% CI: 1.02-1.21, p=0.02). Midterm TE predictors were length (OR: 0.95, 95% CI: 0.89-1.01, p=0.08) and torsion maximum location (OR: 1.01, 95% CI: 0.99-1.01, p=0.10). CONCLUSION: The present study confirms that treatment of infrarenal AAA with an Anaconda stent-graft is related to a relatively high TE rate which decreases with a pre-to-postoperative reduction in curvature and TI, and a larger degree of circumferential CIA calcification. In other words, more aortoiliac straightening and more circumferential CIA calcification may prevent TE development after EVAR with this stent-graft.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Boidae , Procedimentos Endovasculares , Masculino , Animais , Humanos , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Stents , Estudos Retrospectivos , Desenho de Prótese , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Aorta Abdominal/cirurgia
7.
Clin Endosc ; 55(4): 540-548, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35898152

RESUMO

BACKGROUND/AIMS: Colorectal polyps are removed to prevent progression to colorectal cancer. Polyp size is an important factor for risk stratification of malignant transformation. Endoscopic size estimation correlates poorly with pathological reports and several factors have been suggested to influence size estimation. We aimed to gain insight into the factors influencing endoscopic polyp size estimation. METHODS: Images of polyps in an artificial model were obtained at 1, 3, and 5 cm from the colonoscope's tip. Participants were asked to estimate the diameter and volume of each polyp. RESULTS: Fifteen endoscopists from three large-volume centers participated in this study. With an intraclass correlation coefficient of 0.66 (95% confidence interval [CI], 0.62-0.71) for diameter and 0.56 (95% CI, 0.50-0.62) for volume. Polyp size estimated at 3 cm from the colonoscope's tip yielded the best results. A lower distance between the tip and the polyp was associated with a larger estimated polyp size. CONCLUSION: Correct endoscopic estimation of polyp size remains challenging. This finding can affect size estimation skills and future training programs for endoscopists.

8.
J Cardiovasc Surg (Torino) ; 63(4): 454-463, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35005875

RESUMO

BACKGROUND: The GORE® EXCLUDER® Iliac Branch Endoprosthesis (IBE) is designed to treat iliac aneurysms with preservation of blood flow through the internal iliac artery (IIA). Little is known about the influence of IBE placement on the IIA geometry. This study aimed to provide detailed insights in the dynamic behavior and geometry of the common iliac artery (CIA) and IIA trajectory and how these are influenced after treatment with an IBE. METHODS: Pre- and postoperative electrocardiogram-gated computed tomography angiography (ECG-gated CTA) scans were acquired in a prospective study design and analyzed with in-house written algorithms designed for aorto-iliac and endoprosthesis deformation evaluation. Cardiac pulsatility-induced motion patterns and pathlengths were computed by tracking predefined locations on the aorto-iliac tract. Centerlines through the CIA-IIA trajectory were used to investigate the static and dynamic geometry, including curvature, torsion, length and Tortuosity Index (TI). RESULTS: Fourteen CIA-IIA trajectories were analyzed before and after IBE placement. Cardiac pulsatility-induced motion and pathlengths increased after IBE placement, especially at mid IIA and the first IIA bifurcation (P≤0.04). After IBE placement, static and dynamic curvature, length and TI decreased significantly (P<0.05). Furthermore, the average dynamic torsion increased significantly (P=0.030). The remaining geometrical outcomes were not statistically significant. CONCLUSIONS: The placement of an IBE device stiffens and straightens the CIA-IIA trajectory. Its relation with clinical outcome is yet to be investigated, which can be done thoroughly with the ECG-gated CTA algorithms used in this study.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Eletrocardiografia , Procedimentos Endovasculares/efeitos adversos , Humanos , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Estudos Prospectivos , Desenho de Prótese , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
9.
Semin Vasc Surg ; 32(3-4): 94-105, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32553125

RESUMO

The emergence of limb occlusion after endovascular aneurysm repair may be related to the conformational changes between the endograft structure and the patient's anatomy. This study analyzed detailed geometric changes of Anaconda endograft (Terumo Aortic, Inchinnan, Scotland, UK) limbs during the cardiac cycle-based computed tomography on serial imaging after graft implantation. Fifteen patients (mean age 72.8 ± 3.7 years; 14 men) underwent postoperative electrocardiogram-gated computed tomography scans according to a prospective study design between April 2014 and May 2017. Changes in curvature, length of the limbs, and distances between successive stent rings (inter-ring distance) of the endograft limbs during a 2-year follow-up period were quantified using meticulous image processing methods involving image registration, centerline extraction, and model-based stent-ring segmentation. From discharge to 24 months, mean curvature increased significantly by 9.6 m-1 (standard deviation [SD], 11.1 m-1; 95% confidence interval [CI], 3.4 to 15.8 m-1; P = .002) for the right limbs and by 6.1 m-1 (SD 9.4 m-1; 95% CI, 0.8 to 11.5 m-1; P = .21) for the left limbs. The length of the right limbs decreased significantly, by 9.5 mm (SD 7.6 mm; 95% CI, 3.5 to 15.6 mm; P = .002); the length of the left limbs decreased by 10.1 mm (SD 5.1 mm; 95% CI, 5.9 to 14.2 mm; P < .001). The minimal inter-ring distance decreased by 0.36 mm (SD 0.26 mm; 95% CI, 0.17 to 0.55 mm; P < .001) for the right limbs and 0.35 mm (SD 0.19 mm; 95% CI, 0.21 to 0.49 mm; P < .001) for the left limbs. Cardiac pulsatility-induced changes in curvature, limb length, and inter-ring distance were negligible (2%, 0.3% and 0.3%, respectively). Changes in the geometry of the Anaconda endograft limbs after endovascular aortic aneurysm repair were observed during a 2-year follow-up manifest as an increase in curvature, shortening of the stent-graft limbs, and a corresponding decrease in inter-ring distance. These stent-graft conformational changes could result in inward folding of the graft fabric, which may relate to the emergence of limb occlusion. Further investigation of these metrics in a larger cohort involving patients with and without occlusions may allow determination of their predictive value.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/etiologia , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Estudos Longitudinais , Masculino , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...