1.
Eur J Heart Fail ; 19(5): 661-669, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28176424

RESUMO

AIMS: Heart failure (HF) treatment guided by physicians with access to real-time pressure measurement from a wireless implantable pulmonary artery pressure (PAP) sensor (CardioMEMS), has previously been shown to reduce HF-related hospital admissions in the CHAMPION trial. However, uncertainty remains regarding the value of CardioMEMS in European health systems where healthcare costs are significantly lower than in the USA. METHODS AND RESULTS: A Markov model was developed to estimate the cost-effectiveness of PAP-guided treatment of HF using the CardioMEMS™ HF system compared with usual care. Cost-effectiveness was measured as the incremental cost per quality-adjusted life year (QALY) gained. In the base case analysis over a time horizon of 10 years, PAP-guided HF therapy increased cost compared with usual care by £10 916 (€14 030). QALYs per patient for usual care and PAP-guided patients were 2.57 and 3.14, respectively, reflecting an increase of 0.57 QALYs with PAP-guided treatment. The resultant incremental cost-effectiveness ratio (ICER) is £19 274 (€24 772) per QALY gained. The base case analysis did not include staff time, due to a lack of data concerning this variable. Running the model with estimated staff time included resulted in an increased ICER of between £22 342 and £25 464 per QALY gained (€28 709-32 721). CONCLUSION: The analysis indicates that integrating wireless PAP monitoring into the management of UK HF patients is likely to be a cost-effective addition to the HF treatment pathway for appropriate patients.


Assuntos
Determinação da Pressão Arterial/economia , Gerenciamento Clínico , Custos de Cuidados de Saúde/estatística & dados numéricos , Insuficiência Cardíaca/economia , Modelos Econômicos , Pressão Propulsora Pulmonar , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Hospitalização/economia , Humanos , Masculino
2.
J Interv Card Electrophysiol ; 40(1): 75-80, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24626999

RESUMO

INTRODUCTION: A quadripolar left ventricular (LV) pacing can deliver multipoint pacing (MPP). It is unknown if this confers improved cardiac function compared to conventional cardiac resynchronization therapy (CRT). METHODS AND RESULTS: We aimed to characterize changes in acute cardiac contractility and hemodynamics with multisite left ventricular "multipoint" pacing (MPP) in a prospective multicenter study in patients implanted with a CRT-defibrillator incorporating a quadripolar LV lead. The device was programmed to deliver MPP acutely pacing with eight configurations of varying timing delays. Global peak LV radial strain and LV outflow velocity time integral (LVOT VTI) were measured for conventional CRT and each MPP configuration. Out of the eight tested MPP configurations, the one that yielded the best echocardiographic measurement for each patient was defined as "optimal MPP". Forty CRT recipients had complete radial strain datasets suitable for analysis. Compared to conventional CRT, the mean peak radial strain was significantly higher for the optimal MPP configuration (18.3 ± 7.4 vs. 9.3 ± 5.3%, p < 0.001), and at least one MPP configuration was significantly superior (>20%) in 63% of patients. LVOT VTI data were collected in a subset of 13 patients. In these patients, mean VTI was significantly higher for optimal MPP compared to conventional CRT (13.5 ± 2.7 vs. 10.9 ± 3.3 cm, p < 0.01). CONCLUSION: MPP delivered via a quadripolar LV lead resulted in a significant improvement in acute cardiac contractility and hemodynamics compared to conventional CRT in the majority of patients studied. CLINICAL TRIAL REGISTRATION: Clinicaltrials.gov identifier NCT01044784.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Contração Miocárdica , Idoso , Eletrodos Implantados , Desenho de Equipamento , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
J Card Fail ; 19(11): 731-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24263116

RESUMO

BACKGROUND: A novel quadripolar left ventricular (LV) pacing lead has the ability to deliver multisite LV pacing (MSLV). We set out to characterize the safety and changes in acute mechanical dyssynchrony with MSLV in cardiac resynchronization therapy (CRT) patients. METHODS AND RESULTS: Prospective multicenter study in 52 patients receiving CRT. An acute pacing protocol comprising 8 MSLV configurations covering a range of delays was compared with conventional CRT (baseline). Transthoracic tissue Doppler imaging (TDI) was used to measure the standard deviation of time to peak contraction of 12 LV segments (Ts-SD) and delayed longitudinal contraction. No ventricular arrhythmia occurred in any of the 52 patients. Complete TDI datasets were collected in 41 patients. Compared with baseline: 1) The mean Ts-SD was significantly lower for the optimal MSLV configuration (35.3 ± 36.4 vs 50.2 ± 29.1 ms; P < .001); 2) at least 1 MSLV configuration exhibited a significant dyssynchrony improvement in 63% of patients; and 3) the mean number of LV segments with delayed longitudinal contractions was significantly reduced with the optimal MSLV configuration (0.37 ± 7.99 vs 2.20 ± 0.19; P < .001). CONCLUSIONS: Acute MSLV was acutely safe, and a proportion of MSLV vectors resulted in a significant reduction in echocardiographic dyssynchrony compared with conventional CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia
4.
Europace ; 14(3): 365-72, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21993431

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) is sometimes complicated by elevated pacing thresholds and phrenic nerve stimulation (PNS), both of which may require that the coronary sinus lead be repositioned. The purpose of this study was to evaluate the performance of a novel quadripolar electrode lead and cardiac resynchronization therapy-defibrillator (CRT-D) device that enables electrical repositioning, potentially obviating a lead reposition procedure. METHODS AND RESULTS: Patients indicated for CRT were enrolled and received a quadripolar electrode lead and CRT-D device (Quartetmodel 1458Q and Promote Q; St Jude Medical, Sylmar, CA, USA). Electrical data, and the presence of PNS during pacing from each left ventricular (LV) configuration, were documented at pre-hospital discharge and at 1 month. Seventy-five patients were enrolled and 71 were successfully implanted with a Quartetlead. Electrical measurements were stable over the follow-up period. Ninety-seven per cent (64 of 66) of patients had one or more programmable configurations with a threshold < 2.5 V and no PNS vs. 86% (57 of 66) if only conventional bipolar configurations were considered. Physicians were able to use the increased programming options to manage threshold changes and PNS. CONCLUSION: The new quadripolar electrode LV lead provides more programming options to address common problems faced when managing CRT patients. Electrical measurements from new vectors are comparable with conventional configurations. Furthermore, 11% of patients in the study suffered PNS on all conventional bipolar vectors.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Nervo Frênico/fisiopatologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
5.
Europace ; 13(7): 984-91, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21498849

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) has dramatically improved the symptoms and prognosis of patients with heart failure in large randomized clinical trials. Optimization of device settings may maximize benefit on an individual basis, although the best method for this is not yet established. We evaluated the use of cardiogenic impedance measurements (derived from intracardiac impedance signals) in CRT device optimization, using invasive left ventricular (LV) dP/dtmax as the reference. METHODS AND RESULTS: Seventeen patients underwent invasive haemodynamic assessment using a pressure wire placed in the LV cavity at the time of CRT device implantation. Intracardiac impedance measurements were made at different atrioventricular (AV) and interventricular (VV) delays and compared with LV dP/dtmax. We assessed the performance of patient-specific and generic impedance-based models in predicting acute haemodynamic response to CRT. In two patients, LV catheterization with the pressure wire was unsuccessful and in two patients LV lead delivery was unsuccessful; therefore, data were acquired for 13 out of 17 patients. Left ventricular dP/dtmax was 919±182 mmHg/s at baseline and this increased acutely (by 24%) to 1121±226 mmHg/s as a result of CRT. The patient-specific impedance-based model correctly predicted the optimal haemodynamic response (to within 5% points) for AV and VV delays in 90 and 92% of patients, respectively. CONCLUSION: Cardiogenic impedance measurements are capable of correctly identifying the maximum achievable LV dP/dtmax as measured by invasive haemodynamic assessment. This study suggests that cardiogenic impedance can potentially be used for CRT optimization and may have a role in ambulatory assessment of haemodynamics.


Assuntos
Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco/fisiopatologia , Contração Miocárdica/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Impedância Elétrica , Eletrocardiografia , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
6.
Circ Heart Fail ; 4(2): 170-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21216832

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) using endocardial left ventricular (LV) pacing may be superior to conventional CRT. We studied the acute hemodynamic response to conventional CRT and LV pacing from different endocardial sites using a combined cardiac MRI and LV noncontact mapping (NCM) protocol to gain insights into the underlying mechanisms. METHODS AND RESULTS: Fifteen patients (age, 63 ± 10 years; 12 men) awaiting CRT were studied in a combined x-ray and MRI laboratory. Delayed-enhancement cardiac magnetic resonance was performed to define areas of myocardial fibrosis. Patients underwent an electrophysiological study incorporating endocardial and epicardial LV pacing. Acute hemodynamic response was measured using a pressure wire within the LV cavity to derive LV dP/dt max. NCM was used to define areas of slow conduction. There was a significant improvement in all LV pacing modes versus baseline (P<0.001). LV endocardial CRT from the best endocardial site was superior to conventional CRT, with a 79.8 ± 49.0% versus 59.6 ± 49.5% increase in LV dP/dt max of from baseline (P<0.05). The hemodynamic benefits of pacing were greater when LV stimulation was performed outside of areas of slow conduction defined by NCM (P<0.001). Delayed-enhancement cardiac magnetic resonance was able to delineate zones of slow conduction seen with NCM in ischemic patients but was unreliable in nonischemic patients. CONCLUSIONS: Endocardial LV pacing appears superior to conventional CRT, although the optimal site varies between subjects and is influenced by pacing within areas of slow conduction. Delayed-enhancement cardiac magnetic resonance was a poor predictor of zones of slow conduction in nonischemic patients.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Imageamento por Ressonância Magnética , Pericárdio/fisiopatologia , Idoso , Análise de Variância , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Pressão Ventricular , Raios X