1.
Heart Surg Forum ; 8(4): E266-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16112940

RESUMO

BACKGROUND: The implementation of a total endoscopic coronary surgery on the beating heart with the aid of the Da Vinci surgical system (Intuitive, Sunnyvale, CA) requires a stepwise learning process. After cadaveric training and clinical start of the program in November 2002, we gained experience with arrested heart procedures starting in May 2003. In November 2003, we moved to beating heart surgery. METHODS: From November 2003 to January 2005, 14 patients with coronary artery disease (mean age of 62 +/- 5 years, female to male ratio 2:12) were operated with the intention to perform a beating heart TECAB (totally endoscopic coronary artery bypass grafting) procedure. RESULTS: Total conversion rate was 35% (5/14), due to pleural adhesions in 2 patients, injury of the lung during port placement, inability to occlude the LAD with saddle loops, atherosclerotic diseased mammary artery in 1 patient each. Mean operating time was 298 +/- 110 minutes with a steady decline throughout the study period (first 5 patients: 342 +/- 61 minutes, patients 6 to 9: 337 +/- 87 minutes, last 4 patients: 290 +/- 53 minutes), resulting in a 60 minute shorter operating time. Mean ICU stay was 1.3 days and hospital stay lasted on average 8.4 +/- 2.8 days. CONCLUSION: Total endoscopic bypass surgery on the beating heart with the Da Vinci surgical system can be safely implemented in clinical use. The learning curve results in a constantly decreasing procedure time due to a more effective table team-console surgeon-robotic system interaction and a moderate conversion rate.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Endoscopia/métodos , Robótica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Heart Valve Dis ; 13(3): 439-43, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15222291

RESUMO

BACKGROUND AND AIM OF THE STUDY: EuroSCORE is widely used to assess operative risk. Combined cardiac procedures carry increased perioperative mortality, but the influence of preoperative factors on mid-term outcome is not well known for these patients. The study aim was to determine if EuroSCORE risk influences mid-term survival after combined coronary artery bypass grafting (CABG) and valve surgery. METHODS: Follow up (mean 23.7 months) was obtained in 258 consecutive hospital survivors (148 males, 110 females; median age 72.29 years; mean EuroSCORE 7 points) operated on between January 1998 and March 2001. CABG + aortic valve replacement (AVR) was performed in 171 patients, CABG + mitral surgery in 72, and CABG + double valve surgery in 15. Kaplan-Meier estimates were calculated for survival and combined freedom from death and NYHA class III/IV. The Cox regression model was applied to prove the influence of EuroSCORE risk and a number of preoperative and operative variables on mid-term outcome. RESULTS: Thirty patients (11.63%) died during follow up, and 34 (13.17%) were in NYHA class III/IV. Freedom from death and NYHA class III/IV was 89.3%, 74.7% and 55.2% at 12, 24 and 36 months, respectively. The significant predictor for combined death and NYHA class III/IV was EuroSCORE risk (p = 0.0004). In the subgroup of patients with CABG + mitral valve surgery, age was identified as a significant risk factor for death (p = 0.0346), whereas in the subgroup of patients with CABG + AVR EuroSCORE was detected as significant risk factor for combined death and NYHA class III/IV. CONCLUSION: EuroSCORE is an important predictor for poor mid-term outcome after combined CABG and valve surgery.


Assuntos
Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Valva Mitral/cirurgia , Risco Ajustado , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Análise de Sobrevida , Resultado do Tratamento
3.
Heart Surg Forum ; 7(5): E485-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15799930

RESUMO

BACKGROUND: Sixteen patients (mean age, 30.9 +/- 12.9 years; range, 9-79 years) with incompetent bicuspid aortic valves underwent valve-sparing correction between 1992 and 1995. METHODS: All patients underwent triangular resection of the enlarged leaflet. In addition, 13 patients underwent commissuroplasty. In 3 patients leaflet perforations were corrected with glutaraldehyde-fixed autologous pericardial patch. All patients underwent annual echocardiographic and clinical examinations at our institution. RESULTS: During follow-up 1 patient died of heart failure, and 3 patients underwent reoperations because of valve incompetence or dilatation of the sinus. Two patients underwent reoperation perioperatively. At long-term follow-up (mean, 10.06 +/- 1.01 years) the remaining 10 patients were in New York Heart Association class I. No patient was receiving anticoagulation, and no thromboembolic, bleeding, or endocarditis events were observed in 107.2 cumulative patientyears of follow-up. Mean grade of regurgitation was 0.7 +/- 0.5; mean aortic flow velocity was 2.29 +/- 0.47 m/s. Optimal valvular function led to normal ventricular diameters (left ventricular end systolic diameter, 39.2 +/- 4.3 mm; left ventricular end diastolic diameter, 56.2 +/- 5.9 mm) and normal ventricular function (fractional shortening, 31.5% +/- 0.1%). The dimensions of the aortic root were stable from 1-year to late followup (mean aortic annulus, 27.1 +/- 6.8 mm; sinus of Valsalva, 33.0 +/- 7.1 mm; sinotubular junction, 34.1 +/- 7.7 mm; ascending aorta, 31.6 +/- 7.4 mm). CONCLUSION: In contrast to early follow-up results of 5 reoperations, clinical and echocardiographic results were excellent for 10 patients who had undergone reconstruction of bicuspid incompetent aortic valves, and the patients were in stable condition after 10 years. However, the mode of early failure is unknown. Reconstruction of bicuspid valves is possible in selected patients.


Assuntos
Valva Aórtica/anormalidades , Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/anormalidades , Valva Mitral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Adolescente , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Criança , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia
4.
Eur J Cardiothorac Surg ; 21(3): 470-3, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11888765

RESUMO

OBJECTIVE: Structural differences of the pulmonary root may predispose it to progressive dilatation in the systemic circulation after the Ross operation. We identified the incidence and risk factors of pulmonary autograft root dilatation. METHODS: One hundred and seven adult patients (mean age of 36+/-11 years) were followed after the Ross operation since 1991 including an echocardiogram within 3 months of surgery and yearly clinical assessment and echocardiography. The autograft was measured at the maximum diameter of the sinus (SV) and aortic insufficiency (AI) assessed. A SV of >37 mm was considered as root dilatation and the incidence over time was calculated using the Kaplan-Meier method. Clinically relevant dilatation was defined as a root diameter of >42 mm. In addition, we determined the percentage change of the sinus diameter between the early and latest echocardiogram. Furthermore we tested the influence of patient variables and risk factors on dilatation. RESULTS: By 1 year, dilatation was found in 21 patients (20%). The SV was >42 mm in eight patients (7%). By 7 years, only 45% of patients were free of dilatation. Eleven patients (10%) had a SV of >42 mm. Increase in SV was time related and linear. However, 90% of patients showed <25% dilatation during follow-up. Time from operation, early SV diameter, male gender and surgical technique were identified as significant risk factors of dilatation. However, dilatation has not lead to reoperation due to aneurysm formation or development of significant AI. CONCLUSIONS: We conclude that time dependent autograft root dilation occurs but does not cause an increase in AI and need for reoperation up to 7 years. These findings warrant the pursuit of the concept of the Ross operation in young patients who regain excellent functional status and life style without anticoagulation.


Assuntos
Valva Aórtica/cirurgia , Valva Pulmonar/transplante , Adulto , Dilatação Patológica/patologia , Feminino , Seguimentos , Cardiopatias Congênitas/cirurgia , Humanos , Incidência , Masculino , Estudos Prospectivos , Valva Pulmonar/patologia , Fatores de Risco , Fatores de Tempo , Transplante Autólogo
5.
Ann Thorac Surg ; 73(2): 455-9, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11845859

RESUMO

BACKGROUND: Noncompliant prostheses are used in aortic replacement. We hypothesized that this leads to increased distension and wall stress in the aortic root because of the loss of ventriculo arterial coupling. METHODS: Pressure relations in the aortic root caused by changes of aortic elasticity simulating prosthetic aortic replacement were tested in a computer model. We then developed an in vitro model using porcine aortas and performed in vivo validation. RESULTS: Findings in vitro and in vivo confirmed the predicted changes of the computer model. Pressure amplitude increased significantly by 17% after prosthetic replacement (p < 0.01). Pressure-time differential (Dp/dt) and dicrotic notch pressure amplitude both increased significantly. Echocardiography demonstrated systolic aortic root distension with percentage area change increasing in vitro from 28.2%+/-9.7% to 35.9%+/-10% (p < 0.05) and in vivo from 13.3%+/-3.1% to 24.3%+/-3.1% (p < 0.0001). Aortic root wall stress increased markedly. CONCLUSIONS: Replacement of the aorta with vascular prostheses causes important negative alterations of hemodynamics and increases in wall stress.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular , Simulação por Computador , Complicações Pós-Operatórias/etiologia , Animais , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/cirurgia , Pressão Sanguínea/fisiologia , Elasticidade , Humanos , Modelos Cardiovasculares , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Suínos , Resistência Vascular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...