Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Inform Health Soc Care ; 44(1): 48-69, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29035624

RESUMO

INTRODUCTION: The majority of medication apps support medication adherence. Equally, if not more important, is medication safety. Few apps report on medication safety, and fewer studies have been conducted with these apps. OBJECTIVES: The usability of a medication safety app was tested with nurses to reveal their perceptions of the graphical user interface and to discover problems they encountered in using the app. METHODS: Usability testing of the app was conducted with RN-BSN students and informatics students (n = 18). Perceptions of the graphical components were gathered in pretest and posttest questionnaires, and video recordings of the usability testing were transcribed. The significance of the difference in mean performance time for 8 tasks was tested, and qualitative analysis was deployed to identify problems encountered and to rate the severity of each problem. RESULTS: While all participants perceived the graphical user interface as easy to understand, nurses took significantly more time to complete certain tasks. More nurses found the medication app to be lacking in intuitiveness of user interface design, in capability to match real-world data, and in providing optimal information architecture. CONCLUSION: To successfully integrate mobile devices in healthcare, developers must address the problems that nurses encountered in use of the app.


Assuntos
Atitude do Pessoal de Saúde , Erros de Medicação/prevenção & controle , Aplicativos Móveis , Enfermeiras e Enfermeiros/psicologia , Segurança do Paciente , Adolescente , Adulto , Feminino , Humanos , Masculino , Informática Médica/educação , Pessoa de Meia-Idade , Percepção , Estudantes , Interface Usuário-Computador , Adulto Jovem
2.
MCN Am J Matern Child Nurs ; 32(2): 117-21, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17356419

RESUMO

PURPOSE: To evaluate the effectiveness of an interventional protocol for the early initiation of breastfeeding that would remove barriers in the labor, delivery, recovery (LDR) unit. STUDY DESIGN AND METHODS: Descriptive design using 100 postpartum mothers who were interviewed before discharge at a large university hospital in the south-central United States. Descriptive statistics were used for analysis. RESULTS: The protocol was effective for initiating breastfeeding, and breastfeeding increased from 53% to 66%. CLINICAL IMPLICATIONS: When barriers to breastfeeding are reduced in the LDR setting, women will breastfeed. It is possible that reducing hospital barriers to breastfeeding in the LDR can also set the stage for sustained breastfeeding during hospitalization and for less supplementation with formula.


Assuntos
Aleitamento Materno , Mães/educação , Enfermagem Obstétrica/organização & administração , Educação de Pacientes como Assunto/organização & administração , Cuidado Pós-Natal/organização & administração , Atitude Frente a Saúde , Aleitamento Materno/psicologia , Aleitamento Materno/estatística & dados numéricos , Protocolos Clínicos , Parto Obstétrico/enfermagem , Parto Obstétrico/psicologia , Feminino , Promoção da Saúde/organização & administração , Humanos , Kentucky , Trabalho de Parto/psicologia , Mães/psicologia , Papel do Profissional de Enfermagem , Avaliação em Enfermagem , Pesquisa em Avaliação de Enfermagem , Avaliação de Resultados em Cuidados de Saúde , Planejamento de Assistência ao Paciente/organização & administração , Cuidado Pós-Natal/psicologia , Gravidez , Avaliação de Programas e Projetos de Saúde , Estudos Retrospectivos , Inquéritos e Questionários , Fatores de Tempo
3.
Breast J ; 10(4): 337-44, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15239793

RESUMO

Many modifications in the technique of sentinel lymph node (SLN) biopsy for breast cancer have taken place since it was first introduced. This analysis was undertaken to determine, in a large multi-institutional study, whether SLN biopsy results have improved over time. Patients with clinical stage T1-2, N0 breast cancer were enrolled in this prospective study between August 1997 and February 2002. SLN biopsy was performed using blue dye and/or radioactive colloid along with completion level I/II axillary dissection in all patients. The majority of subjects included in this study represent the surgeons' initial experience with SLN biopsy for breast cancer. Statistical comparison of the SLN identification (ID) rate and false-negative (FN) rate were performed by chi-squared analysis. A total of 3370 subjects from 300 surgeons were enrolled in the study. Collectively the SLN ID rate, as well as the mean number of SLNs removed per patient has improved, while the FN rate has remained fairly constant over time. The improved ID rate may be related to improved technical details, while the FN rate has not changed significantly. This highlights the ongoing need for surgeons to perform backup axillary dissection during their initial learning phase.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Biópsia de Linfonodo Sentinela , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Reações Falso-Negativas , Feminino , Humanos , Metástase Linfática , Mastectomia , Pessoa de Meia-Idade , Estudos Prospectivos , Biópsia de Linfonodo Sentinela/métodos , Biópsia de Linfonodo Sentinela/normas
4.
Breast J ; 9(1): 26-32, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12558667

RESUMO

Previous studies have shown that independent of tumor size, palpable breast tumors have a higher incidence of lymph node metastasis compared with nonpalpable tumors. This study further examines this phenomenon using a large sentinel lymph node (SLN) database. Data from a prospective, institutional review board (IRB)-approved, multi-institutional study from the University of Louisville Breast Cancer Sentinel Lymph Node Study Group was used. From August 1997 through December 2001, 3192 patients with clinical T1 and T2 N0 breast cancer underwent SLN biopsy, most with a combined technique of radioactive colloid and blue dye, followed by level I/II axillary dissection. Patients with palpable tumors tended to be younger (mean age 58 years) compared with nonpalpable tumors (mean age 61 years). The incidence of positive axillary metastasis was significant between palpable and nonpalpable tumors (43% and 23%, respectively), independent of tumor size by logistic regression (p = 0.0001). The SLN identification rate was significantly different between palpable and nonpalpable tumors (95% versus 91%, respectively; p < 0.0001). A unifying theory to explain the phenomenon that palpable tumors, stage for stage, are associated with a higher rate of nodal metastasis is that palpable tumors are, on average, closer to the skin and the rich network of dermal lymphatics. We believe that the dermal lymphatics of the breast represent a clinically relevant metastatic pathway to the axilla.


Assuntos
Neoplasias da Mama/patologia , Palpação , Biópsia de Linfonodo Sentinela , Fatores Etários , Axila , Mama/patologia , Feminino , Humanos , Incidência , Linfonodos/patologia , Metástase Linfática/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias
5.
Breast J ; 8(4): 192-8, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12100110

RESUMO

Increasing tumor burden in the axilla, as determined by the number of positive lymph nodes, adversely affects sentinel lymph node (SLN) identification and false-negative rates. The University of Louisville Breast Cancer Sentinel Lymph Node Study is a prospective, multi-institutional study. All enrolled patients underwent SLN biopsy, followed by complete level I/II axillary dissection. Participating surgeons represent a variety of practice settings, mostly community-based private practice. A total of 229 surgeons enrolled 2206 patients between August 1997 and November 2000. SLN biopsy was performed using blue dye injection alone, radioactive colloid alone, or a combination of the two agents. Two key parameters used to measure SLN biopsy success are the SLN identification rate and SLN false-negative rate. The overall SLN identification and false-negative rates were 92.5% and 8.0%, respectively. With increasing numbers of positive axillary nodes, there was a decreased sentinel node identification rate. There was no difference in the false-negative rate with increasing axillary tumor burden. Increased tumor burden in the axilla (as determined by the mean number of positive nodes) is associated with failure to identify a SLN in some cases, but is not an explanation for false-negative results. Standard axillary dissection should be performed when a SLN cannot be identified.


Assuntos
Neoplasias da Mama/patologia , Metástase Linfática/patologia , Biópsia de Linfonodo Sentinela/normas , Axila , Reações Falso-Negativas , Feminino , Humanos , Linfonodos/patologia , Pessoa de Meia-Idade , Estadiamento de Neoplasias/normas , Padrões de Prática Médica/estatística & dados numéricos , Valor Preditivo dos Testes , Estudos Prospectivos , Estados Unidos
6.
Ann Surg Oncol ; 9(3): 272-7, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11923134

RESUMO

BACKGROUND: It has been suggested that sentinel lymph node (SLN) biopsy for breast cancer may be less accurate after excisional biopsy of the primary tumor compared with core needle biopsy. Furthermore, some have suggested an improved ability to identify the SLN when total mastectomy is performed compared with lumpectomy. This analysis was performed to determine the impact of the type of breast biopsy (needle vs. excisional) or definitive surgical procedure (lumpectomy vs. mastectomy) on the accuracy of SLN biopsy. METHODS: The University of Louisville Breast Cancer Sentinel Lymph Node Study is a prospective multi-institutional study. Patients with clinical stage T1-2, N0 breast cancer were eligible. All patients underwent SLN biopsy and completion level I/II axillary dissection. Statistical comparison was performed by chi(2) analysis. RESULTS: A total of 2206 patients were enrolled in the study. There were no statistically significant differences in SLN identification rate or false-negative rate between patients undergoing excisional versus needle biopsy. The SLN identification and false-negative rates also were not statistically different between patients who had total mastectomy compared with those who had a lumpectomy. CONCLUSIONS: Excisional biopsy does not significantly affect the accuracy of SLN biopsy, nor does the type of definitive surgical procedure.


Assuntos
Neoplasias da Mama/patologia , Excisão de Linfonodo , Mastectomia Radical , Mastectomia Segmentar , Biópsia de Linfonodo Sentinela , Adulto , Idoso , Idoso de 80 Anos ou mais , Axila , Biópsia por Agulha , Reações Falso-Negativas , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...