Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 65(1): 47-53, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15800891

RESUMO

Our goal was to develop and prove the accuracy of a system that would allow us to re-create live patient arterial pathology. Anatomically accurate replicas of blood vessels could allow physicians to teach and practice dangerous interventional techniques and might also be used to gather basic physiologic information. The preparation of replicas has, until now, depended on acquisition of fresh cadaver material. Using rapid prototyping, it should be able to replicate vascular pathology in a live patient. We obtained CT angiographic scan data from two patients with known arterial abnormalities. We took such data and, using proprietary software, created a 3D replica using a commercially available rapid prototyping machine. From the prototypes, using a lost wax technique, we created vessel replicas, placed those replicas in the CT scanner, then compared those images with the original scans. Comparison of the images made directly from the patient and from the replica showed that with each step, the relationships were maintained, remaining within 3% of the original, but some smoothing occurred in the final computer manipulation. From routinely obtainable CT angiographic data, it is possible to create accurate replicas of human vascular pathology with the aid of commercially available stereolithography equipment. Visual analysis of the images appeared to be as important as the measurements. With 64 and 128 slice detector scanners becoming available, acquisition times fall enough that we should be able to model rapidly moving structures such as the aortic root.


Assuntos
Angiografia/métodos , Artéria Basilar/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Aneurisma Intracraniano/diagnóstico por imagem , Modelos Anatômicos , Tomografia Computadorizada por Raios X , Procedimentos Cirúrgicos Vasculares/métodos , Estenose das Carótidas/cirurgia , Humanos , Processamento de Imagem Assistida por Computador , Aneurisma Intracraniano/cirurgia , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Vasculares/normas
2.
Artigo em Inglês | MEDLINE | ID: mdl-15544234

RESUMO

There are three reasons to create physical replicas of human anatomy: (1) to be able to better visualize the shape of a single organ, or a section of anatomy; (2) to be able to visualize the spatial relationships in three-dimensions; and (3) to use accurate replicas to practice or rehearse otherwise high-risk clinical procedures in the laboratory. This paper describes a project to fabricate a carotid artery. It discusses the gathering of data, the conversion to a volume, and the subsequent conversion to a manufacturable form.


Assuntos
Artérias Carótidas/anatomia & histologia , Modelos Anatômicos , California , Artérias Carótidas/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...