Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Hazard Mater ; 405: 124210, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33092877

RESUMO

Finding effective methods for simultaneous removal of antibiotics and heavy metals has attracted increasing concerns. Herein, we investigated the co-adsorption behaviors of chlortetracycline (CTC) and Pb (II) onto struvite loaded diatomite (SD) in aqueous solution, and their interface interactions mechanism was investigated using crystal and microstructure analysis combined with density functional theory (DFT) calculations. The adsorption capacity at equilibrium of CTC increased from 44.28 to 87.58 mmol/kg with the presence of Pb (II), but the adsorption capacity at equilibrium of Pb (II) decreased from 4289.70 to 3559.9 mmol/kg with the presence of CTC. Besides, the effect of environmental factors (solution pH and humic acid) was also evaluated. Microstructure analysis for recovered products demonstrated that the interface interactions brought by the surface Pb(II) of Pb5(PO4)3OH and carbonyl-O of CTC could facilitate the removal of CTC but inhibit the removal of Pb(II) by suppressing the crystal growth of Pb5(PO4)3OH, especially the orientation growth of (0 0 1) crystal plane. DFT calculations gave theoretical support for the interface interactions between Pb5(PO4)3OH and CTC.


Assuntos
Clortetraciclina , Poluentes Químicos da Água , Adsorção , Terra de Diatomáceas , Chumbo , Estruvita , Poluentes Químicos da Água/análise
2.
Talanta ; 69(2): 450-5, 2006 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18970588

RESUMO

A highly sensitive, fast and stable conductometric enzyme biosensor for determination of nitrate in water is reported for the first time. The biosensor electrodes were modified by methyl viologen mediator mixed with nitrate reductase (NR) from Aspergillus niger by cross-linking with glutaraldehyde in the presence of bovine serum albumin and Nafion((R)) cation-exchange polymer. The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH, the enzyme loading and time of immobilization in glutaralaldehyde vapor were investigated with regard to their influence on sensitivity, limit of detection, dynamic range and operational and storage stability. The biosensor can reach 95% of steady-state conductance value in about 15s. Linear calibration in the range of 0.02 and 0.25 mM with detection limits of 0.005 mM nitrate was obtained with a signal-to-noise ratio of 3. When stored in 5 mM phosphate buffer (pH 7.5) at 4 degrees C, the sensor showed good stability over 2 weeks.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...