1.
J Orthop Surg Res ; 19(1): 295, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750567

RESUMO

INTRODUCTION: Hip arthroplasty is a common orthopaedic procedure worldwide. There is an ongoing debate related to the fixation and anaesthesia impact on the 30-day mortality, particularly in the aging population with higher American Society of Anaesthesiology (ASA) Physical-Status. AIM: To study the 30-day all-cause mortality in patients undergoing primary hip arthroplasty, with regards to the impact of age, ASA-class, anaesthesia techniques, indication for surgery and fixation techniques. MATERIALS AND METHODS: Perioperative data for primary hip arthroplasty procedures for osteoarthritis and hip fractures registered in the Swedish Perioperative Registry (SPOR) between 2013 and June 2022 were collected. Binary logistic regressions were performed to assess the impact of age, ASA-class, anaesthetic technique, indication for surgery and fixation on odds ratio for 30-day mortality in Sweden. RESULTS: In total, 79,114 patients, 49,565 with osteoarthritis and 29,549 with hip fractures were included in the main study cohort. Mortality was significantly higher among hip fracture patients compared with osteoarthritis, cumulative 8.2% versus 0.1% at 30-days respectively (p < 0.001). Age above 80 years (OR3.7), ASA 3-5 (OR3.3) and surgery for hip fracture (OR 21.5) were associated with significantly higher odds ratio, while hybrid fixation was associated with a significantly lower odds ratio (OR0.4) of 30-day mortality. In the same model, for the subgroups of osteoarthritis and hip fracture, only age (OR 3.7) and ASA-class (OR 3.3) had significant impact, increasing the odds ratio for 30-day mortality. Hemi arthroplasty was commonly used among the hip fracture patients 20.453 (69.2%), and associated with a significantly higher odds ratio for all-cause 30-day mortality as compared to total hip arthroplasty when adjusting for age and ASA-class and fixation 2.3 (95%CI 1.9-2.3, p < 0.001). CONCLUSIONS: All-cause 30-day mortality associated with arthroplasty differed significantly between the two cohorts, hip fracture, and osteoarthritis (8.2% and 0.1% respectively) and mortality expectedly increased with age and higher ASA-class. Anaesthetic method and cement-fixation did not impact the odds ratio for all-cause 30-day mortality after adjustment for age and ASA-class.


Assuntos
Artroplastia de Quadril , Fraturas do Quadril , Osteoartrite do Quadril , Sistema de Registros , Humanos , Artroplastia de Quadril/mortalidade , Suécia/epidemiologia , Idoso , Feminino , Masculino , Idoso de 80 Anos ou mais , Fraturas do Quadril/cirurgia , Fraturas do Quadril/mortalidade , Osteoartrite do Quadril/cirurgia , Osteoartrite do Quadril/mortalidade , Pessoa de Meia-Idade , Fatores Etários , Estudos de Coortes , Fatores de Tempo
2.
Bone Joint J ; 100-B(12): 1592-1599, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30499312

RESUMO

AIMS: The primary aim of this study was to compare the wear properties of vitamin E-diffused, highly crosslinked polyethylene (VEPE) and one formulation of moderately crosslinked and mechanically annealed ultra-high molecular weight polyethylene (ModXLPE) in patients five years after primary total hip arthroplasty (THA). The secondary aim was to assess the clinical results of patients treated with VEPE by evaluating patient-reported outcome measures (PROMs), radiological evidence of fixation, and the incidence of mechanical failure. PATIENTS AND METHODS: A total of 208 patients (221 THAs) from four international centres were recruited into a prospective study involving radiostereometric analysis (RSA) and the assessment of clinical outcomes. A total of 193 hips (87%) were reviewed at the five-year follow-up. Of these, 136 (70%) received VEPE (vs ModXLPE) liners and 68 (35%) received ceramic (vs metal) femoral heads. PROMs and radiographs were collected preoperatively and at one, two, and five years postoperatively. In addition, RSA images were collected to measure PE wear postoperatively and at one, two, and five years after surgery. RESULTS: We observed similar bedding in one year postoperatively and wear two years postoperatively between the two types of liner. However, there was significantly more penetration of the femoral head in the ModXLPE cohort compared with the VEPE cohort five years postoperatively (p < 0.001). The only variables independently predictive of increased wear were ModXLPE (vs VEPE) liner type (ß = 0.22, p = 0.010) and metal (vs ceramic) femoral head (ß = 0.21, p = 0.013). There was no association between increased wear and the development of radiolucency (p = 0.866) or PROMs. No patient had evidence of osteolysis. CONCLUSION: Five years postoperatively, patients with VEPE (vs ModXLPE) and ceramic (vs metal) femoral heads had decreased wear. The rates of wear for both liners were very low and have not led to any osteolysis or implant failure due to aseptic loosening.


Assuntos
Artroplastia de Quadril/métodos , Reagentes de Ligações Cruzadas , Prótese de Quadril , Polietilenos/química , Vitamina E/análise , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Estudos Prospectivos , Desenho de Prótese , Análise Radioestereométrica , Estresse Mecânico , Fatores de Tempo
3.
Bone Joint J ; 99-B(1): 37-43, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28053255

RESUMO

AIMS: It has been suggested that cemented fixation of total hip arthroplasty (THA) is associated with an increased peri-operative mortality compared with cementless THA. Our aim was to investigate this through a nationwide matched cohort study adjusting for age, comorbidity, and socioeconomic background. PATIENTS AND METHODS: A total of 178 784 patients with osteoarthritis who underwent either cemented or cementless THA from the Swedish Hip Arthroplasty Register were matched with 862 294 controls from the general population. Information about the causes of death, comorbidities, and socioeconomic background was obtained. Mortality within the first 90 days after the operation was the primary outcome measure. RESULTS: Patients who underwent cemented THA had an increased risk of death during the first 14 days compared with the controls (hazard ratio (HR) 1.3, confidence interval (CI) 1.11 to 1.44), corresponding to an absolute increase in risk of five deaths per 10 000 observations. No such early increase of risk was seen in those who underwent cementless THA. Between days 15 and 29 the risk of mortality was decreased for those with cemented THA (HR 0.7, CI 0.62 to 0.87). Between days 30 and 90 all patients undergoing THA, irrespective of the mode of fixation, had a lower risk of death than controls. Patients selected for cementless fixation were younger, healthier and had a higher level of education and income than those selected for cemented THA. A supplementary analysis of 16 556 hybrid THAs indicated that cementation of the femoral component was associated with a slight increase in mortality up to 15 days, whereas no such increase in mortality was seen in those with a cemented acetabular component combined with a cementless femoral component. CONCLUSION: This nationwide matched cohort study indicates that patients receiving cemented THA have a minimally increased relative risk of early mortality that is reversed from day 15 and thereafter. The absolute increase in risk is very small. Our findings lend support to the idea that cementation of the femoral component is more dangerous than cementation of the acetabular component. Cite this article: Bone Joint J 2017;99-B:37-43.


Assuntos
Artroplastia de Quadril/mortalidade , Cimentos Ósseos/efeitos adversos , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos de Casos e Controles , Cimentação/efeitos adversos , Cimentação/métodos , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Suécia/epidemiologia , Fatores de Tempo
4.
Orthop Traumatol Surg Res ; 102(8): 1049-1054, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27863919

RESUMO

INTRODUCTION: Adopting the direct lateral (DL) instead of the posterolateral (PL) approach in hip arthroplasty for femoral neck fracture (FNF) patients could lower the rate of prosthetic dislocation. However, little is known about how the approach influences the functional outcome. HYPOTHESIS: We hypothesized that both approaches would give comparable results. MATERIAL AND METHODS: In a prospective cohort study, we enrolled 185 hips (183 patients, 128 women, median age 84 years) with a displaced FNF. Subjects were assigned to treatment using DL (n=102) or PL approach (n=83) with a hemiarthroplasty (HA). Functional outcome was assessed by Harris Hip Score (HHS), Western Ontario and McMaster Universities Arthritis (WOMAC) index, pain numeric rating scale (PNRS) for pain, mortality and hip complications. Patients were followed-up after 1 year. RESULTS: The HHS was 71 (SD 18) in the DL group and 72 (SD 17) in the PL group (P=0.59). We found no difference in WOMAC, PNRS and mortality. Seven patients (6.9%) in the DL group and 11 patients (13.3%) in the PL group had undergone a major reoperation (adjusted OR 0.51; 95% CI, 0.18-2.07; P=0.23). DISCUSSION: In this prospective cohort study, patients treated with HA for FNF using either the DL or PL approaches had comparable functional outcome after 1 year. The PL approach had a tendency towards a higher reoperation rate. TYPE OF STUDY: Prospective cohort study. LEVEL OF PROOF: Level 2.


Assuntos
Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Articulação do Quadril/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Hemiartroplastia/efeitos adversos , Luxação do Quadril/etiologia , Humanos , Masculino , Medição da Dor , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Reoperação , Resultado do Tratamento
5.
Bone Joint J ; 95-B(9): 1184-91, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23997129

RESUMO

While an increasing amount of arthroplasty articles report comorbidity measures, none have been validated for outcomes. In this study, we compared commonly used International Classification of Diseases-based comorbidity measures with re-operation rates after total hip replacement (THR). Scores used included the Charlson, the Royal College of Surgeons Charlson, and the Elixhauser comorbidity score. We identified a nationwide cohort of 134 423 THRs from the Swedish Hip Arthroplasty Register. Re-operations were registered post-operatively for up to 12 years. The hazard ratio was estimated by Cox's proportional hazards regression, and we used C-statistics to assess each measure's ability to predict re-operation. Confounding variables were age, gender, type of implant fixation, hospital category, hospital implant volume and year of surgery. In the first two years only the Elixhauser score showed any significant relationship with increased risk of re-operation, with increased scores for both one to two and three or more comorbidities. However, the predictive C-statistic in this period for the Elixhauser score was poor (0.52). None of the measures proved to be of any value between two and 12 years. They might be of value in large cohort or registry studies, but not for the individual patient.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Osteoartrite do Quadril/cirurgia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/epidemiologia , Estudos Prospectivos , Sistema de Registros , Reoperação/estatística & dados numéricos , Distribuição por Sexo , Suécia/epidemiologia , Fatores de Tempo
6.
J Bone Joint Surg Br ; 93(5): 665-77, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21511934

RESUMO

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck. We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years. Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D. Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (-2.1 to +0.5) and a retroversion of a mean of 1.2° (-8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (-49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years. The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.


Assuntos
Fraturas do Colo Femoral/cirurgia , Prótese de Quadril , Fraturas por Osteoporose/cirurgia , Absorciometria de Fóton/métodos , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Densidade Óssea , Remodelação Óssea , Cimentação , Materiais Revestidos Biocompatíveis , Durapatita , Métodos Epidemiológicos , Feminino , Fraturas do Colo Femoral/fisiopatologia , Fêmur/fisiopatologia , Humanos , Vértebras Lombares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/fisiopatologia , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Resultado do Tratamento