Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagn Interv Imaging ; 105(3): 97-103, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38261553

RESUMO

PURPOSE: The purpose of this study was to propose a deep learning-based approach to detect pulmonary embolism and quantify its severity using the Qanadli score and the right-to-left ventricle diameter (RV/LV) ratio on three-dimensional (3D) computed tomography pulmonary angiography (CTPA) examinations with limited annotations. MATERIALS AND METHODS: Using a database of 3D CTPA examinations of 1268 patients with image-level annotations, and two other public datasets of CTPA examinations from 91 (CAD-PE) and 35 (FUME-PE) patients with pixel-level annotations, a pipeline consisting of: (i), detecting blood clots; (ii), performing PE-positive versus negative classification; (iii), estimating the Qanadli score; and (iv), predicting RV/LV diameter ratio was followed. The method was evaluated on a test set including 378 patients. The performance of PE classification and severity quantification was quantitatively assessed using an area under the curve (AUC) analysis for PE classification and a coefficient of determination (R²) for the Qanadli score and the RV/LV diameter ratio. RESULTS: Quantitative evaluation led to an overall AUC of 0.870 (95% confidence interval [CI]: 0.850-0.900) for PE classification task on the training set and an AUC of 0.852 (95% CI: 0.810-0.890) on the test set. Regression analysis yielded R² value of 0.717 (95% CI: 0.668-0.760) and of 0.723 (95% CI: 0.668-0.766) for the Qanadli score and the RV/LV diameter ratio estimation, respectively on the test set. CONCLUSION: This study shows the feasibility of utilizing AI-based assistance tools in detecting blood clots and estimating PE severity scores with 3D CTPA examinations. This is achieved by leveraging blood clots and cardiac segmentations. Further studies are needed to assess the effectiveness of these tools in clinical practice.


Assuntos
Aprendizado Profundo , Embolia Pulmonar , Trombose , Humanos , Tomografia Computadorizada por Raios X/métodos , Embolia Pulmonar/diagnóstico por imagem , Ventrículos do Coração , Estudos Retrospectivos
2.
J Imaging ; 9(3)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36976120

RESUMO

Generative adversarial networks (GANs) have become increasingly powerful, generating mind-blowing photorealistic images that mimic the content of datasets they have been trained to replicate. One recurrent theme in medical imaging, is whether GANs can also be as effective at generating workable medical data, as they are for generating realistic RGB images. In this paper, we perform a multi-GAN and multi-application study, to gauge the benefits of GANs in medical imaging. We tested various GAN architectures, from basic DCGAN to more sophisticated style-based GANs, on three medical imaging modalities and organs, namely: cardiac cine-MRI, liver CT, and RGB retina images. GANs were trained on well-known and widely utilized datasets, from which their FID scores were computed, to measure the visual acuity of their generated images. We further tested their usefulness by measuring the segmentation accuracy of a U-Net trained on these generated images and the original data. The results reveal that GANs are far from being equal, as some are ill-suited for medical imaging applications, while others performed much better. The top-performing GANs are capable of generating realistic-looking medical images by FID standards, that can fool trained experts in a visual Turing test and comply to some metrics. However, segmentation results suggest that no GAN is capable of reproducing the full richness of medical datasets.

3.
Med Image Anal ; 79: 102428, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35500498

RESUMO

A key factor for assessing the state of the heart after myocardial infarction (MI) is to measure whether the myocardium segment is viable after reperfusion or revascularization therapy. Delayed enhancement-MRI or DE-MRI, which is performed 10 min after injection of the contrast agent, provides high contrast between viable and nonviable myocardium and is therefore a method of choice to evaluate the extent of MI. To automatically assess myocardial status, the results of the EMIDEC challenge that focused on this task are presented in this paper. The challenge's main objectives were twofold. First, to evaluate if deep learning methods can distinguish between non-infarct and pathological exams, i.e. exams with or without hyperenhanced area. Second, to automatically calculate the extent of myocardial infarction. The publicly available database consists of 150 exams divided into 50 cases without any hyperenhanced area after injection of a contrast agent and 100 cases with myocardial infarction (and then with a hyperenhanced area on DE-MRI), whatever their inclusion in the cardiac emergency department. Along with MRI, clinical characteristics are also provided. The obtained results issued from several works show that the automatic classification of an exam is a reachable task (the best method providing an accuracy of 0.92), and the automatic segmentation of the myocardium is possible. However, the segmentation of the diseased area needs to be improved, mainly due to the small size of these areas and the lack of contrast with the surrounding structures.


Assuntos
Aprendizado Profundo , Infarto do Miocárdio , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia
4.
Comput Med Imaging Graph ; 97: 102049, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35334316

RESUMO

Cardiovascular disease is a major cause of death worldwide. Computed Tomography Coronary Angiography (CTCA) is a non-invasive method used to evaluate coronary artery disease, as well as evaluating and reconstructing heart and coronary vessel structures. Reconstructed models have a wide array of for educational, training and research applications such as the study of diseased and non-diseased coronary anatomy, machine learning based disease risk prediction and in-silico and in-vitro testing of medical devices. However, coronary arteries are difficult to image due to their small size, location, and movement, causing poor resolution and artefacts. Segmentation of coronary arteries has traditionally focused on semi-automatic methods where a human expert guides the algorithm and corrects errors, which severely limits large-scale applications and integration within clinical systems. International challenges aiming to overcome this barrier have focussed on specific tasks such as centreline extraction, stenosis quantification, and segmentation of specific artery segments only. Here we present the results of the first challenge to develop fully automatic segmentation methods of full coronary artery trees and establish the first large standardized dataset of normal and diseased arteries. This forms a new automated segmentation benchmark allowing the automated processing of CTCAs directly relevant for large-scale and personalized clinical applications.


Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Algoritmos , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X/métodos
5.
Can J Cardiol ; 38(2): 196-203, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34780990

RESUMO

Generative adversarial networks (GANs) are state-of-the-art neural network models used to synthesise images and other data. GANs brought a considerable improvement to the quality of synthetic data, quickly becoming the standard for data-generation tasks. In this work, we summarise the applications of GANs in the field of cardiology, including generation of realistic cardiac images, electrocardiography signals, and synthetic electronic health records. The utility of GAN-generated data is discussed with respect to research, clinical care, and academia. And we present illustrative examples of our GAN-generated cardiac magnetic resonance and echocardiography images, showing the evolution in image quality across 6 different models, which have become almost indistinguishable from real images. Finally, we discuss future applications, such as modality translation or patient trajectory modelling. Moreover, we discuss the pending challenges that GANs need to overcome, namely, their training dynamics, the medical fidelity or the data regulations and ethics questions, to become integrated in cardiology workflows.


Assuntos
Cardiologia , Diagnóstico por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Humanos
6.
IEEE Trans Med Imaging ; 39(11): 3703-3713, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32746116

RESUMO

Convolutional neural networks (CNN) have had unprecedented success in medical imaging and, in particular, in medical image segmentation. However, despite the fact that segmentation results are closer than ever to the inter-expert variability, CNNs are not immune to producing anatomically inaccurate segmentations, even when built upon a shape prior. In this paper, we present a framework for producing cardiac image segmentation maps that are guaranteed to respect pre-defined anatomical criteria, while remaining within the inter-expert variability. The idea behind our method is to use a well-trained CNN, have it process cardiac images, identify the anatomically implausible results and warp these results toward the closest anatomically valid cardiac shape. This warping procedure is carried out with a constrained variational autoencoder (cVAE) trained to learn a representation of valid cardiac shapes through a smooth, yet constrained, latent space. With this cVAE, we can project any implausible shape into the cardiac latent space and steer it toward the closest correct shape. We tested our framework on short-axis MRI as well as apical two and four-chamber view ultrasound images, two modalities for which cardiac shapes are drastically different. With our method, CNNs can now produce results that are both within the inter-expert variability and always anatomically plausible without having to rely on a shape prior.


Assuntos
Imageamento por Ressonância Magnética , Redes Neurais de Computação , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...