Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 31(7): 812-8, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18684277

RESUMO

BACKGROUND: To study the feasibility and efficacy of video-assisted thoracoscopic (VAT) placement of the left ventricular pacing lead for cardiac resynchronization therapy (CRT) where the conventional transvenous coronary sinus approach has failed. METHODS: Seventeen patients underwent the VAT procedure. Indications for CRT were ischemic cardiomyopathy in six patients and nonischemic cardiomyopathy in 11. The procedure was performed under general anesthesia with single-lung ventilation. Three 2-cm incisions were used on the left chest wall to place the screw-in lead near the obtuse marginal arteries high on the lateral wall of the left ventricle (LV). RESULTS: The VATS approach was successful in 13/17 (76%) patients. Median procedure time was 75 minutes (range 55-135). A learning curve was observed that appeared to plateau at 75 minutes procedure time after four cases. Median length of hospital stay was 2 days (range 2-8) with one patient requiring intensive care. Satisfactory thresholds and impedances of 2.3 +/- 0.9 V/0.5 ms and 560 ohms, respectively, were achieved at mean follow-up of 226 days. All patients reported symptomatic benefit with reduction in New York Heart Association score from III preoperatively to II postoperatively. CONCLUSIONS: VAT placement of the epicardial pacing lead is feasible, safe, and efficacious. It should be considered in cases where the transvenous route has failed or as an alternative in prolonged or hazardous transvenous procedures.


Assuntos
Arritmias Cardíacas/patologia , Arritmias Cardíacas/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Eletrodos Implantados , Marca-Passo Artificial , Implantação de Prótese/métodos , Cirurgia Torácica Vídeoassistida/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/prevenção & controle
2.
Pacing Clin Electrophysiol ; 27(5): 686-7, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15125733

RESUMO

This report describes the case of a 22-year-old patient presenting with ICD electrode failure where attempted percutaneous electrode extraction was unsuccessful. In view of the patient's young age, an operative approach was considered most appropriate. The failed electrode was surgically extracted and a new epicardial pacing/defibrillator system inserted.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Adulto , Ponte de Artéria Coronária , Remoção de Dispositivo , Falha de Equipamento , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...