Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Obstet Gynecol MFM ; 6(4): 101345, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38479490

RESUMO

BACKGROUND: Poor outcomes from operative vaginal birth have been associated with failure to recognize malposition, breakdown in interdisciplinary communication, and deviation from accepted guidelines. We recently implemented a safety bundle including routine intrapartum ultrasound and a structured time-out and procedural checklist aiming to reduce maternal and perinatal morbidity from operative vaginal birth. OBJECTIVE: This study aimed to compare births where intrapartum ultrasound was used and those where it was not used during a safety bundle implementation period at Monash Health. STUDY DESIGN: We performed a retrospective cohort study at Monash Health during the transitional phase of implementing an operative vaginal birth safety bundle. We studied all women with operative vaginal birth and fully dilated cesarean delivery with a singleton cephalic term fetus. We compared births for which intrapartum ultrasound was used and those for which it was not. The primary outcome was neonates delivered in an unexpected position. Neonatal and maternal morbidity were also assessed, including a neonatal composite of Apgar score <7 at 5 minutes, cord lactate >8 mmol/L, need for resuscitation, significant birth trauma, or neonatal intensive care unit admission. To control for confounding by indication, we estimated propensity scores for the probability of using intrapartum ultrasound for each case based on maternal and labor characteristics, and adjusted the effect estimates for the propensity scores using multivariable logistic regression models. RESULTS: From August 2022 to July 2023, there were 1205 operative vaginal births or fully dilated cesarean deliveries at Monash Health, including 743 (61.7%) forceps, 346 (28.7%) vacuum, and 116 (9.6%) fully dilated cesarean deliveries. Over this time, we observed increased uptake of intrapartum ultrasound from 26% in August 2022 to 60% (P<.001) in July 2023, of the time-out from 21% to 58% (P<.001), and the checklist from 33% to 80% (P<.001) of operative second-stage births. Among the births where intrapartum ultrasound was used (n=509), compared with those where it was not (n=696), there were significantly more forceps births (67% vs 58%; adjusted odds ratio, 1.35; 95% confidence interval, 1.05-1.74; P=.021) and a reduction in vacuum births (24% vs 32%; adjusted odds ratio, 0.77; 95% confidence interval, 0.58-1.01; P=.059). There were no significant differences in fully dilated cesarean delivery or maternal morbidity. Intrapartum ultrasound use was associated with significantly fewer infants being delivered in an unexpected position (0.2% vs 2.2%; adjusted odds ratio, 0.08; 95% confidence interval, 0.00-0.44; P=.019) and a significant reduction in composite neonatal morbidity (22% vs 25%; adjusted odds ratio, 0.73; 95% confidence interval, 0.54-0.97; P=.031). CONCLUSION: During the implementation of a safety bundle, the use of ultrasound before operative vaginal birth was associated with fewer infants delivered in an unexpected position and reduced neonatal morbidity.


Assuntos
Cesárea , Humanos , Feminino , Estudos Retrospectivos , Gravidez , Adulto , Recém-Nascido , Cesárea/estatística & dados numéricos , Cesárea/métodos , Ultrassonografia Pré-Natal/métodos , Ultrassonografia Pré-Natal/estatística & dados numéricos , Índice de Apgar , Extração Obstétrica/métodos , Extração Obstétrica/estatística & dados numéricos , Estudos de Coortes , Pontuação de Propensão , Lista de Checagem/métodos , Vácuo-Extração/estatística & dados numéricos , Vácuo-Extração/métodos , Vácuo-Extração/efeitos adversos
2.
Eur J Obstet Gynecol Reprod Biol ; 285: 193-197, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37148646

RESUMO

Clinical prediction models assist clinicians to estimate the natural course of a condition, and thus facilitate treatment decisions. The development of prediction models is increasingly common in obstetric research. Composite outcomes, whereby multiple outcomes are combined into a single endpoint, are frequently used in obstetric prediction models to increase statistical power when predicting rare events. Although existing literature has reviewed the positives and negatives of using composite outcomes in clinical trials, there has been minimal commentary on the implications of their use in the development and reporting of prognostic models. In this article, we review these issues, in particular, highlighting how unequal individual relationships between predictors and individual component outcomes can result in misleading conclusions, which may result in the omission of important but rare predictors or inappropriately inform clinical decisions to implement an intervention. We propose careful use, or where possible avoidance, of composite outcomes in the development of prognostic models in obstetrics. Methodological standards for developing prognostic models should be updated to standardise and appraise composite outcomes when their use is necessary. We also support previous recommendations to report on the accuracy of key components and inconsistencies among predictor variables.


Assuntos
Modelos Estatísticos , Obstetrícia , Gravidez , Feminino , Humanos , Prognóstico
3.
Am J Obstet Gynecol ; 229(1): 10-22.e10, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36427598

RESUMO

OBJECTIVE: This study aimed to compare the prognostic accuracy of intrapartum transperineal ultrasound measures of fetal descent before operative vaginal birth in predicting complicated or failed procedures. DATA SOURCES: We performed a predefined systematic search in Medline, Embase, CINAHL, and Scopus from inception to June 10, 2022. STUDY ELIGIBILITY CRITERIA: We included studies assessing the following intrapartum transperineal ultrasound measures before operative vaginal birth to predict procedure outcome: angle of progression, head direction, head-perineum distance, head-symphysis distance, midline angle, and/or progression distance. METHODS: Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Bivariate meta-analysis was used to pool sensitivities and specificities into summary receiver operating characteristic curves for each intrapartum transperineal ultrasound measure. Subgroup analyses were performed for measures taken at rest vs with pushing and prediction of failed vs complicated operative vaginal birth. RESULTS: Overall, 16 studies involving 2848 women undergoing attempted operative vaginal birth were included. The prognostic accuracy of intrapartum transperineal ultrasound measures taken at rest to predict failed or complicated operative vaginal birth was high for angle of progression (area under the receiver operating characteristic curve, 0.891; 9 studies) and progression distance (area under the receiver operating characteristic curve, 0.901; 3 studies), moderate for head direction (area under the receiver operating characteristic curve, 0.791; 6 studies) and head-perineum distance (area under the receiver operating characteristic curve, 0.747; 8 studies), and fair for midline angle (area under the receiver operating characteristic curve, 0.642; 4 studies). There was no study with sufficient data to assess head-symphysis distance. Subgroup analysis showed that measures taken with pushing tended to have a higher area under the receiver operating characteristic curve for angle of progression (0.927; 4 studies), progression distance (0.930; 2 studies), and midline angle (0.903; 3 studies), with a similar area under the receiver operating characteristic curve for head direction (0.802; 4 studies). The prediction of failed vs complicated operative vaginal birth tended to be less accurate for angle of progression (0.837 [4 studies] vs 0.907 [6 studies]) and head direction (0.745 [3 studies] vs 0.810 [5 studies]), predominantly because of lower specificity, and was more accurate for head-perineum distance (0.812 [6 studies] vs 0.687 [2 studies]). CONCLUSION: Angle of progression, progression distance, and midline angle measured with pushing demonstrated the highest prognostic accuracy in predicting complicated or failed operative vaginal birth. Overall, the measurements seem to perform better with pushing than at rest.


Assuntos
Apresentação no Trabalho de Parto , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Prognóstico , Ultrassonografia Pré-Natal/métodos , Estudos Prospectivos , Ultrassonografia , Cabeça/diagnóstico por imagem
4.
Arch Dis Child Fetal Neonatal Ed ; 104(6): F609-F616, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30728180

RESUMO

OBJECTIVE: Fetoscopic endoluminal tracheal occlusion (FETO) aims to reverse pulmonary hypoplasia associated with congenital diaphragmatic hernia (CDH) and mitigate the associated respiratory insufficiency and pulmonary hypertension after birth. We aimed to determine whether FETO improves the cardiopulmonary transition at birth in an ovine model of CDH. METHODS: In 12 ovine fetuses with surgically induced diaphragmatic hernia (DH; 80 dGA), an endotracheal balloon was placed tracheoscopically at ≈110 dGA and removed at ≈131 dGA (DH+FETO), while 10 were left untreated (DH). At ≈138 dGA, all lambs (survival at delivery: 67% [DH+FETO], 70% [DH]) were delivered via caesarean section and ventilated for 2 hours. Physiological and ventilation parameters were continuously recorded, and arterial blood-gas values were measured. RESULTS: Compared with DH, DH+FETO lambs had increased wet lung-to-body-weight ratio (0.031±0.004 vs 0.016±0.002) and dynamic lung compliance (0.7±0.1 vs 0.4±0.1 mL/cmH2O). Pulmonary vascular resistance was lower in DH+FETO lambs (0.44±0.11 vs 1.06±0.17 mm Hg/[mL/min]). However, after correction for lung weight, pulmonary blood flow was not significantly different between the groups (4.19±0.57 vs 4.05±0.60 mL/min/g). Alveolar-arterial difference in oxygen tension was not significantly different between DH+FETO and DH (402±41mm Hg vs 401±45 mm Hg). CONCLUSIONS: FETO accelerated lung growth in fetuses with CDH and improved neonatal respiratory function during the cardiopulmonary transition at birth. However, despite improved lung compliance and reduced pulmonary vascular resistance, there were less pronounced benefits for gas exchange during the first 2 hours of life.


Assuntos
Fetoscopia/métodos , Hérnias Diafragmáticas Congênitas/cirurgia , Traqueia/cirurgia , Obstrução das Vias Respiratórias , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Feto , Pulmão/fisiopatologia , Troca Gasosa Pulmonar , Testes de Função Respiratória , Ovinos , Resistência Vascular/fisiologia
5.
Arch Dis Child Fetal Neonatal Ed ; 104(6): F617-F623, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30728182

RESUMO

OBJECTIVE: Infants with a congenital diaphragmatic hernia (CDH) are at high risk of developing pulmonary hypertension after birth, but little is known of their physiological transition at birth. We aimed to characterise the changes in cardiopulmonary physiology during the neonatal transition in an ovine model of CDH. METHODS: A diaphragmatic hernia (DH) was surgically created at 80 days of gestational age (dGA) in 10 fetuses, whereas controls underwent sham surgery (n=6). At 138 dGA, lambs were delivered via caesarean section and ventilated for 2 hours. Physiological and ventilation parameters were continuously recorded, and arterial blood gas values were measured. RESULTS: DH lambs had lower wet lung-to-body-weight ratio (0.016±0.002vs0.033±0.004), reduced dynamic lung compliance (0.4±0.1mL/cmH2O vs1.2±0.1 mL/cmH2O) and reduced arterial pH (7.11±0.05vs7.26±0.05), compared with controls. While measured pulmonary blood flow (PBF) was lower in DH lambs, after correction for lung weight, PBF was not different between groups (4.05±0.60mL/min/gvs4.29±0.57 mL/min/g). Cerebral tissue oxygen saturation was lower in DH compared with control lambs (55.7±3.5vs67.7%±3.9%). CONCLUSIONS: Immediately after birth, DH lambs have small, non-compliant lungs, respiratory acidosis and poor cerebral oxygenation that reflects the clinical phenotype of human CDH. PBF (indexed to lung weight) was similar in DH and control lambs, suggesting that the reduction in PBF associated with CDH is proportional to the degree of lung hypoplasia during the neonatal cardiopulmonary transition.


Assuntos
Hérnias Diafragmáticas Congênitas/fisiopatologia , Acidose Respiratória/fisiopatologia , Animais , Animais Recém-Nascidos , Pressão Arterial/fisiologia , Gasometria , Modelos Animais de Doenças , Idade Gestacional , Pulmão/fisiopatologia , Troca Gasosa Pulmonar/fisiologia , Respiração Artificial/métodos , Testes de Função Respiratória , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...