Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 84(3): 1661-1671, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32077521

RESUMO

PURPOSE: Motion artifact limits the clinical translation of high-field MR. We present an optical prospective motion correction system for 7 Tesla MRI using a custom-built, within-coil camera to track an optical marker mounted on a subject. METHODS: The camera was constructed to fit between the transmit-receive coils with direct line of sight to a forehead-mounted marker, improving upon prior mouthpiece work at 7 Tesla MRI. We validated the system by acquiring a 3D-IR-FSPGR on a phantom with deliberate motion applied. The same 3D-IR-FSPGR and a 2D gradient echo were then acquired on 7 volunteers, with/without deliberate motion and with/without motion correction. Three neuroradiologists blindly assessed image quality. In 1 subject, an ultrahigh-resolution 2D gradient echo with 4 averages was acquired with motion correction. Four single-average acquisitions were then acquired serially, with the subject allowed to move between acquisitions. A fifth single-average 2D gradient echo was acquired following subject removal and reentry. RESULTS: In both the phantom and human subjects, deliberate and involuntary motion were well corrected. Despite marked levels of motion, high-quality images were produced without spurious artifacts. The quantitative ratings confirmed significant improvements in image quality in the absence and presence of deliberate motion across both acquisitions (P < .001). The system enabled ultrahigh-resolution visualization of the hippocampus during a long scan and robust alignment of serially acquired scans with interspersed movement. CONCLUSION: We demonstrate the use of a within-coil camera to perform optical prospective motion correction and ultrahigh-resolution imaging at 7 Tesla MRI. The setup does not require a mouthpiece, which could improve accessibility of motion correction during 7 Tesla MRI exams.


Assuntos
Artefatos , Encéfalo , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Neuroimagem , Estudos Prospectivos
2.
Magn Reson Med ; 80(1): 36-41, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29193287

RESUMO

PURPOSE: Although 1 H spin coupling is generally avoided in probes for hyperpolarized (HP) 13 C MRI, enzymatic transformations of biological interest can introduce large 13 C-1 H couplings in vivo. The purpose of this study was to develop and investigate the application of 1 H decoupling for enhancing the sensitivity for detection of affected HP 13 C metabolic products. METHODS: A standalone 1 H decoupler system and custom concentric 13 C/1 H paddle coil setup were integrated with a clinical 3T MRI scanner for in vivo 13 C MR studies using HP [2-13 C]dihydroxyacetone, a novel sensor of hepatic energy status. Major 13 C-1 H coupling JCH = ∼150 Hz) is introduced after adenosine triphosphate-dependent enzymatic transformation of HP [2-13 C]dihydroxyacetone to [2-13 C]glycerol-3-phosphate in vivo. Application of WALTZ-16 1 H decoupling for elimination of large 13 C-1 H couplings was first tested in thermally polarized glycerol phantoms and then for in vivo HP MR studies in three rats, scanned both with and without decoupling. RESULTS: As configured, 1 H-decoupled 13 C MR of thermally polarized glycerol and the HP metabolic product [2-13 C]glycerol-3-phosphate was achieved at forward power of approximately 15 W. High-quality 3-s dynamic in vivo HP 13 C MR scans were acquired with decoupling duty cycle of 5%. Application of 1 H decoupling resulted in sensitivity enhancement of 1.7-fold for detection of metabolic conversion of [2-13 C]dihydroxyacetone to HP [2-13 C]glycerol-3-phosphate in vivo. CONCLUSIONS: Application of 1 H decoupling provides significant sensitivity enhancement for detection of HP 13 C metabolic products with large 1 H spin couplings, and is therefore expected to be useful for preclinical and potentially clinical HP 13 C MR studies. Magn Reson Med 80:36-41, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Isótopos de Carbono/química , Imageamento por Ressonância Magnética , Prótons , Animais , Temperatura Corporal , Meios de Contraste/química , Di-Hidroxiacetona/metabolismo , Glicerol/química , Processamento de Imagem Assistida por Computador , Fígado/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Imagens de Fantasmas , Ácido Pirúvico/química , Ondas de Rádio , Ratos
3.
NMR Biomed ; 24(8): 927-32, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21416540

RESUMO

A novel polarizer based on the dissolution-dynamic nuclear polarization (DNP) method has been designed, built and tested. The polarizer differs from those previously described by being designed with sterile use intent and being compatible with clinical use. The main features are: (1) an integral, disposable fluid path containing all pharmaceuticals constituting a sterile barrier, (2) a closed-cycle cryogenic system designed to eliminate consumption of liquid cryogens and (3) multi-sample polarization to increase throughput. The fluid path consists of a vial with the agent to be polarized, a pair of concentric inlet and outlet tubes connected to a syringe with dissolution medium and a receiver, respectively. The fluid path can operate at up to 400 K and 2.0 MPa and generates volumes as high as 100 mL. An inline filter removes the amount of electron paramagnetic agent in the final product by more than 100-fold in the case of [1-(13)C]pyruvate. The system uses a sorption pump in conjunction with a conventional cryocooler. The system operates through cycles of pumping to low temperature and regeneration of the sorption pump. The magnet accommodates four samples at the same time. A temperature of less than 1 K was achieved for 68 h (no sample heat loads) with a liquid helium volume of 2.4 L. The regeneration of the liquid helium could be achieved in less than 10 h, and the transition to cold (< 1.2 K) was achieved in less than 90 min. A solid state polarization of 36 ± 4% for [1-(13)C]pyruvic acid was obtained with only 10 mW of microwave power. The loading of a sample adds less than 50 J of heat to the helium bath by introducing the sample over 15 min. The heat load imposed on the helium bath during dissolution was less than 70 J. The measured liquid state polarization was 18 ± 2%.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Esterilização , Ácido Pirúvico/metabolismo , Temperatura
4.
Angew Chem Int Ed Engl ; 37(7): 948-949, 1998 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-29711496

RESUMO

Only 170 milliseconds are required to cool the catalyst bed by 150 K in the catalytic reactor shown on the right. Thus, NMR spectroscopic investigations can be carried out on products that are formed after very short contact times and under real catalysis conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...