Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Audiol ; : 1-8, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38319187

RESUMO

OBJECTIVE: to evaluate the levels of successful hearing preservation and preservation of functional hearing following cochlear implantation (HPCI) in children using the Cochlear Nucleus® Slim Straight Electrode (SSE). DESIGN: retrospective case note review of paediatric HPCI cases in our CI centre from 2013 to 2023. Inclusion criteria were attempted hearing preservation surgery, SSE used for implantation, pre-operative hearing thresholds ≤80dBHL at 250 Hz, CI before 18 years of age. Patients were excluded if no postoperative unaided PTA was obtained (poor attendance). Primairy outcome was hearing preservation using the HEARRING group formula; secondary outcome was residual functional hearing (≤80dBHL at 250 Hz/<90dB LFPTA). STUDY SAMPLE: 56 patients with 94 CI's were included for review. RESULTS: Hearing preservation was achieved in 94.7% (89/94) of ears and complete preservation in 72% (68/94)). Average functional hearing was preserved in 89% using both criteria for preservation. Long-term follow up data was available for 36 ears (average 35.2 months), demonstrating 88.9% (32/36) complete preservation. CONCLUSION: We have reliably achieved and maintained a high success rate of HPCI using the SSE in our paediatric population. The field of HPCI would benefit from unification of outcome reporting in order to optimise the evidence available to professionals, patients and their carers.

2.
BMJ Open ; 13(6): e071168, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37339839

RESUMO

INTRODUCTION: In the new revised National Institute for Health & Care Excellence (NICE, TA566, 2019) guidelines for cochlear implantation (CI) have clearly stipulated that the hearing loss must be bilateral. Prior to this revision, children and young people (CYP) with asymmetrical thresholds have been considered for unilateral CI when one ear was in audiological criteria. Children with asymmetrical hearing loss represent an important cohort of potential CI candidates, who will continue to be prevented from benefiting from CI unless evidence is produced to support implantation and maximise subsequent benefit.The aim of this study is to evaluate the 'real-life' hearing performance in a group of children who have received a unilateral CI and who have hearing thresholds in the contralateral ear that are outside the current UK NICE 2019 audiological criteria for CI. The contralateral ear will be aided using a conventional hearing aid (HA). The outcomes from this 'bimodal' group will be compared with a group of children who have received bilateral CI, and a group of children using bilateral HA, to extend the current knowledge about the different performance levels between bilateral CI, bilateral HA and bimodal hearing in CYP. METHODS AND ANALYSIS: Thirty CYP aged 6-17 years old, 10 bimodal users, 10 bilateral HA users and 10 bilateral cochlear implant users will be subjected to a test battery consisting of: (1) spatial release from masking, (2) complex pitch direction discrimination, (3) melodic identification, (4) perception of prosodic features in speech and (5) TEN test. Subjects will be tested in their optimal device modality. Standard demographic and hearing health information will be collected. In the absence of comparable published data to power the study, sample size was determined on pragmatic grounds. Tests are exploratory and for hypothesis generating purposes. Therefore, the standard criterion of p<0.05 will be used. ETHICS AND DISSEMINATION: This has been approved by the Health Research Authority and NHS REC within the UK (22/EM/0104). Industry funding was secured via a competitive researcher-led grant application process. Trial results will be subject to publication according to the definition of the outcome presented in this protocol.


Assuntos
Implante Coclear , Implantes Cocleares , Auxiliares de Audição , Percepção da Fala , Criança , Humanos , Adolescente , Implante Coclear/métodos , Estudos de Casos e Controles , Audição , Reino Unido
3.
BMJ Open ; 13(5): e067248, 2023 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-37156582

RESUMO

INTRODUCTION: Cochlear implantation with hearing preservation (HPCI) has allowed a cochlear implant (CI) electrode to be implanted while trying to preserve residual acoustic low-frequency hearing. The concept arises from the importance of this low-frequency information and the limitations of a CI in several auditory domains. The combination of electrical hearing with either preserved acoustic hearing or amplified 'natural' hearing has the potential to address these issues and enable children with HPCI to closely follow normal auditory development.The aim of this study is to evaluate the 'real-life' benefit of preserved acoustic low-frequency hearing in children with a CI, understand the benefits of preserved natural hearing in complex listening situations and so enable parents and children to make an informed choice about implantation. Ultimately, helping to ensure the maximum number of children benefit from this life-changing intervention. METHODS AND ANALYSIS: Nineteen ears in children and young people aged 6-17 years old with 'successful' HPCI will be subjected to a test battery consisting of: (1) spatial release from masking; (2) complex pitch direction discrimination; (3) melodic identification; (4) perception of prosodic features in speech and (5) threshold equalising noise test. Subjects will be tested in the electro-acoustic stimulation (EAS)/electro-natural stimulation (ENS) and the electric-only (ES) condition, thereby acting as their own control group. Standard demographic and hearing health information will be collected. In the absence of comparable published data to power the study, sample size was determined on pragmatic grounds. Tests are exploratory and for hypothesis-generating purposes. Therefore, the standard criterion of p<0.05 will be used. ETHICS AND DISSEMINATION: This study has been approved by the Health Research Authority and NHS Research Ethics Committee (REC) within the UK (22/EM/0017). Industry funding was secured via a competitive researcher-led grant application process. Trial results will be subject to publication according to the definition of the outcome presented in this protocol.


Assuntos
Implante Coclear , Percepção da Fala , Criança , Humanos , Adolescente , Implante Coclear/métodos , Estudos de Casos e Controles , Percepção da Fala/fisiologia , Limiar Auditivo/fisiologia , Audição
4.
BMJ Open ; 13(2): e069719, 2023 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-36806144

RESUMO

INTRODUCTION: The clinical application of listening effort (LE) is challenging due to the lack of consensus regarding measuring the concept. Correlational analysis between different measuring instruments shows conditional and weak relationships, indicating they capture different dimensions of LE. Current research has suggested possible links between LE and downstream consequences such as fatigue, stress and confidence. One way to clinically measure LE would be to focus on its corollaries. Further research is needed to explore whether tools used to measure these downstream effects can be applied to capture LE. This study explores using existing questionnaire-based outcome instruments to evaluate LE and its associated consequences in children and young people (CYP), with and without hearing loss. METHODS AND ANALYSIS: One hundred CYP aged 12-17 years with normal hearing and a range of hearing loss levels will be invited to complete a series of online questionnaires (Speech, Spatial and Qualities, Vanderbilt Fatigue Scale-Child, Perceived Stress Scale and Rosenberg Self-Esteem Scale) and a hearing test (Digits in Noise). They will complete the questionnaires at two time points (1) at the end of a rest day and (2) at the end of a workday. Standard demographic and hearing health information will be collected. The sample size was determined pragmatically due to a lack of comparable published data to power the study. Tests are exploratory and for generating hypotheses; therefore, the standard criterion of p<0.05 will be used. ETHICS AND DISSEMINATION: This study has been reviewed within the funding organisation (Cochlear Research and Development Limited) by an independent and relevant peer reviewer/committee. This study has had a favourable ethics committee review by both NHS ethics and University of Manchester ethics. The study will be disseminated through newsletters, publication and presentations at conferences. The results will be made available to participants on request.


Assuntos
Surdez , Perda Auditiva , Humanos , Adolescente , Esforço de Escuta , Audição , Fadiga
5.
Trends Hear ; 27: 23312165221137116, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36636020

RESUMO

Listening effort (LE) describes the cognitive resources needed to process an auditory message. Our understanding of this notion remains in its infancy, hindering our ability to appreciate how it impacts individuals with hearing impairment effectively. Despite the myriad of proposed measurement tools, a validated method remains elusive. This is complicated by the seeming lack of association between tools demonstrated via correlational analyses. This review aims to systematically review the literature relating to the correlational analyses between different measures of LE. Five databases were used- PubMed, Cochrane, EMBASE, PsychINFO, and CINAHL. The quality of the evidence was assessed using the GRADE criteria and risk of bias with ROBINS-I/GRADE tools. Each statistically significant analysis was classified using an approved system for medical correlations. The final analyses included 48 papers, equating to 274 correlational analyses, of which 99 reached statistical significance (36.1%). Within these results, the most prevalent classifications were poor or fair. Moreover, when moderate or very strong correlations were observed, they tended to be dependent on experimental conditions. The quality of evidence was graded as very low. These results show that measures of LE are poorly correlated and supports the multi-dimensional concept of LE. The lack of association may be explained by considering where each measure operates along the effort perception pathway. Moreover, the fragility of significant correlations to specific conditions further diminishes the hope of finding an all-encompassing tool. Therefore, it may be prudent to focus on capturing the consequences of LE rather than the notion itself.


Assuntos
Perda Auditiva , Percepção da Fala , Adulto , Humanos , Criança , Esforço de Escuta , Perda Auditiva/diagnóstico , Perda Auditiva/psicologia
6.
Front Public Health ; 9: 669727, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35118034

RESUMO

BACKGROUND: Hearing loss is a major public health challenge. Audiology services need to utilise a range of rehabilitative services and maximise innovative practice afforded by technology to actively promote personalized, participatory, preventative and predictive care if they are to cope with the social and economic burden placed on the population by the rapidly rising prevalence of hearing loss. Digital interventions and teleaudiology could be a key part of providing high quality, cost-effective, patient-centred management. There is currently very limited evidence that assesses the hearing impaired patient perspective on the acceptance and usability of this type of technology. AIM: This study aims to identify patient perceptions of the use of a hearing support system including a mobile smartphone app when used with Bluetooth-connected hearing aids across the everyday life of users, as part of the EVOTION project. METHODS: We applied a questionnaire to 564 participants in three countries across Europe and analysed the following topics: connectivity, hearing aid controls, instructional videos, audiological tests and auditory training. KEY FINDINGS: Older users were just as satisfied as younger users when operating this type of technology. Technical problems such as Bluetooth connectivity need to be minimised as this issue is highly critical for user satisfaction, engagement and uptake. A system that promotes user-controllability of hearing aids that is more accessible and easier to use is highly valued. Participants are happy to utilise monitoring tests and auditory training on a mobile phone out of the clinic but in order to have value the test battery needs to be relevant and tailored to each user, easy to understand and use. Such functions can elicit a negative as well as positive experience for each user. CONCLUSION: Older and younger adults can utilise an eHealth mobile app to complement their rehabilitation and health care. If the technology works well, is tailored to the individual and in-depth personalised guidance and support is provided, it could assist maximisation of hearing aid uptake, promotion of self-management and improving outcomes.


Assuntos
Auxiliares de Audição , Aplicativos Móveis , Telemedicina , Adulto , Audição , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...