1.
Int J Radiat Oncol Biol Phys ; 84(3): e435-40, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-22727886

RESUMO

PURPOSE: To evaluate the dosimetric impact of rotational setup errors in stereotactic body radiotherapy (SBRT) treatment of liver tumors and to investigate whether translational shifts can compensate for rotation. METHODS AND MATERIALS: The positioning accuracy in 20 patients with liver malignancies treated with SBRT was reevaluated offline by matching the patients' cone-beam computed tomography (CT) scans (n=75) to the planning CT scans and adjusting the 3 rotational angles (pitch, roll, and yaw). Systematic and random setup errors were calculated. The dosimetric changes caused by rotational setup errors were quantified for both simulated and observed patient rotations. Dose distributions recalculated on the rotated CT scans were compared with the original planned doses. Translational corrections were simulated based on manual translational registration of the rotated images to the original CT scans. The correction efficacy was evaluated by comparing the recalculated plans with the original plans. RESULTS: The systematic rotational setup errors were -0.06° ± 0.68°, -0.29° ± 0.62°, and -0.24° ± 0.61°; the random setup errors were 0.80°, 1.05°, and 0.61° for pitch, roll, and yaw, respectively. Analysis of CBCT images showed that 56.0%, 14.7%, and 1.3% of treated fractions had rotational errors of >1°, >2°, and >3°, respectively, in any one of the rotational axes. Rotational simulations demonstrated that the reduction of gross tumor volume (GTV) coverage was <2% when rotation was <3°. Recalculated plans using actual patient roll motions showed similar reduction (<2%) in GTV coverage. Translational corrections improved the GTV coverage to within 3% of the original values. For organs at risk (OAR), the dosimetric impact varied case by case. CONCLUSION: Actual rotational setup errors in SBRT for liver tumors are relatively small in magnitude and are unlikely to affect GTV coverage significantly. Translational corrections can be optimized to compensate for rotational setup errors. However, caution regarding possible dose increases to OAR needs to be exercised.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/cirurgia , Órgãos em Risco/diagnóstico por imagem , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia , Carga Tumoral , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Erros de Configuração em Radioterapia/prevenção & controle , Estudos Retrospectivos , Rotação , Incerteza
2.
Brachytherapy ; 10(3): 214-20, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20843747

RESUMO

PURPOSE: Suboptimal dosage evaluated from postimplant dosimetry of prostate brachytherapy creates conundrum that needs resolution. This pilot study was undertaken to explore the feasibility of summing and visualizing radiation dosage from multimodality treatment. METHODS AND MATERIALS: Four weeks after (125)I permanent prostate seed implant, CT scans were performed on the whole pelvis of patients using our standard protocol for prostate planning. The acquired CT data sets were reconstructed using different sizes of field of view (FOV). The images with limited FOV focusing on prostate were imported into Variseed (Varian Medical Systems, Inc., Palo Alto, CA) for postimplant evaluation, whereas images with full FOV were imported to Eclipse (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system (TPS) for future managements, that is, for external beam salvage. RESULTS: The dose matrix resulted from the postimplant dosimetry was exported from Variseed in standard DICOM format and imported into Eclipse TPS. The brachytherapy dose matrix was registered with the patient images with full FOV in Eclipse TPS. Targets for dose boost were defined based on the isodose curves generated from brachytherapy. An external photon beam plan was successfully generated to deliver dose for selected underdose regions. CONCLUSION: Accurate external beam radiation treatment planning can be accomplished using our planning protocols when inadequate brachytherapy dose delivery occurs. The proposed technique can be used to safely deliver additional external radiation dose using intensity-modulated radiation therapy technique after suboptimal brachytherapy procedure.


Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Terapia Combinada , Humanos , Masculino , Dosagem Radioterapêutica
3.
J Contemp Brachytherapy ; 3(4): 220-3, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23346131

RESUMO

PURPOSE: A study was conducted to determine the dosimetric effects resulting from air pockets and high atomic number (Z) contrast medium within a multichannel breast brachytherapy device. MATERIAL AND METHODS: A 5-6 cm diameter Contura (SenoRx) brachytherapy device was inflated using 37 cm(3) of saline. Baseline dose falloff from an HDR Iridium-192 source was measured with the Iridium source centered in the central channel and an anterior off-center channel. Data were collected at distances from 1 to 50 mm. Comparison studies were conducted with identically inflated volume containing varied air pocket volumes (1-4 cm(3)) and concentrations of contrast solution (3%, 6%, and 9% by volume). Dose perturbation factors (DPF) were computed and evaluated. RESULTS: Dose perturbations due to air pockets and contrast solutions were observed. As the volume of air increased, the DPF increased by approximately 2.25%/cm(3). The effect was consistent for both channels. The contrast effects were more complex. The 3% contrast media had minimal dose perturbation. The 6% contrast solution caused dose reduction of 1.0% from the central channel but 1.5% dose increase from the anterior channel. The 9% contrast solution caused dose reductions by 4.0% (from central channel) and 3.0% (from anterior channel). The DPF from all contrast solutions moderated with increasing distance. CONCLUSIONS: Dose perturbations due to air pockets and high-Z contrast solution can be significant. It is important to control these effects to avoid dose errors.

4.
Brachytherapy ; 9(3): 282-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19853531

RESUMO

PURPOSE: A process for prostate high-dose-rate (HDR) brachytherapy was developed and implemented successfully in the community hospital setting. The practical aspects of the program are reviewed and may serve as a foundation for clinics interested in offering this clinical service. METHODS AND MATERIALS: A generic needle distribution geometry was established to accommodate target volumes of variable size. A system to identify and assign treatment channels to each implant needle was devised. The computerized tomography (CT)-based treatment planning was used with dose constraints defined for sensitive structures and target uniformity. Implant needle stability was promoted by supporting the patient on a CT compatible padded sliding board. A process that aligns dwell position to CT imaging without the use of radiographic markers was followed. Graphical optimization of dwell times was used to generate the treatment dose distributions. RESULTS: Prostate HDR brachytherapy as a boost or as monotherapy has been offered in a program that has evolved over the past 8 years. Practical aspects of the program promote its feasibility and precision. Collaboration with commercial entities has also led to the development of products that support the technique. CONCLUSIONS: Prostate HDR brachytherapy offers a relatively high degree of dose distribution control in comparison with other prostate radiotherapy modalities. The practical aspects described offer assurance to achieve that goal.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Agulhas , Neoplasias da Próstata/radioterapia , Desenho de Equipamento , Humanos , Masculino