Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Invasive Cardiol ; 32(9): 335-341, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32568096

RESUMO

OBJECTIVES: We sought to assess the effects of a high loading dose of rosuvastatin (40 mg) on acute inflammatory response after coronary stenting. METHODS: Patients with stable coronary disease without statin use (≥7 days) and undergoing elective percutaneous coronary intervention (PCI) in a native coronary artery were randomized to receive a loading dose of rosuvastatin (n = 64) or not (n = 61). Blood samples were obtained before statin intake (time point A), 3 hours after medication (time point B), and 3 hours after PCI (time point C). The primary goal was the comparison in the variation of the serum inflammatory markers and their gene expression at the different time points between the two groups. RESULTS: Baseline clinical, angiographic, and procedural characteristics did not significantly differ between the groups, except for the more frequent use of postdilation in the control group (73.4% vs 90.2%; P=.02). Patients pretreated with statin showed a reduction in the serum levels of interleukin (IL)-1ß (Δ = -0.491 pg/mL; Pinteraction<.001), IL-6 (Δ = -0.209 pg/mL; Pinteraction<.001), and plasminogen activator inhibitor 1 (Δ = -1.573 pg/mL; Pinteraction<.001) as well as in their genetic expression, which was not observed in the control group. Regarding high-sensitivity c-reactive protein, there was no significant variation in its value from time point A to C in patients pretreated with statin (P=.58) while it significantly increased in the control group (P=.04). CONCLUSIONS: Among patients with stable coronary artery disease undergoing PCI with stents, pretreatment with high dose of rosuvastatin resulted in significant reduction in the serum levels of important inflammatory markers and their genetic expression.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Inflamação , Intervenção Coronária Percutânea , Rosuvastatina Cálcica/administração & dosagem , Proteína C-Reativa/análise , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/cirurgia , Humanos , Inflamação/sangue , Interleucina-1beta/sangue , Intervenção Coronária Percutânea/efeitos adversos , Inibidor 1 de Ativador de Plasminogênio/sangue
2.
Catheter. cardiovasc. interv ; 92(6): 368-e374, Nov. 2018. tab, graf, ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223203

RESUMO

INTRODUCTION: Bioresorbable coronary scaffolds (BRS) have been developed to increase the late safety of coronary angioplasty by providing transitory coronary support and then being fully incorporated to the vessel wall. In the present trial, we sought to evaluate the performance and changes over time in the DESolveTM novolimus-eluting BRS using serial intravascular ultrasound (IVUS) in patients submitted to percutaneous coronary interventions. Methods: Single-center, prospective, non-randomized study involving 17 consecutive patients submitted to implantation of the DESolveTM scaffold and serial evaluated with IVUS at different time points (post procedure, 6 and 18 months). Primary endpoint included the variation in lumen, scaffold, and vessel diameter and area along the months. RESULTS: Angiographic success was achieved in all cases. Scaffold area and volume on IVUS were significantly greater at 6 months than at baseline (6.41 6 1.35 mm2 vs. 7.35 6 1.53 mm2, P < 0.002; and 101.19 6 20.9 mm3 vs. 118.51 6 26.6 mm 3, P 5 0.001). Late lumen loss was 0.22 6 0.30 mm at 6 months and 0.33 6 0.44 mm at 18 months. No major adverse cardiac events occurred. At late follow-up (18 months) the scaffold was not visualized by IVUS; therefore the evaluation was restricted to lumen and vessel at that time point. CONCLUSIONS: IVUS serial evaluation of the novel DESolve BRS showed an increase in the device dimensions between baseline and 6 months, with concomitant enlargement of lumen dimensions and effective suppression of neointimal proliferation. At 18 months, no footprint of the scaffold was detected and the initial lumen enlargement was sustained.


Assuntos
Angioplastia , Stents Farmacológicos , Intervenção Coronária Percutânea
3.
Catheter Cardiovasc Interv ; 92(6): E368-E374, 2018 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-29521477

RESUMO

INTRODUCTION: Bioresorbable coronary scaffolds (BRS) have been developed to increase the late safety of coronary angioplasty by providing transitory coronary support and then being fully incorporated to the vessel wall. In the present trial, we sought to evaluate the performance and changes over time in the DESolve™ novolimus-eluting BRS using serial intravascular ultrasound (IVUS) in patients submitted to percutaneous coronary interventions. METHODS: Single-center, prospective, non-randomized study involving 17 consecutive patients submitted to implantation of the DESolve™ scaffold and serial evaluated with IVUS at different time points (post procedure, 6 and 18 months). Primary endpoint included the variation in lumen, scaffold, and vessel diameter and area along the months. RESULTS: Angiographic success was achieved in all cases. Scaffold area and volume on IVUS were significantly greater at 6 months than at baseline (6.41 ± 1.35 mm2 vs. 7.35 ± 1.53 mm2 , P < 0.002; and 101.19 ± 20.9 mm3 vs. 118.51 ± 26.6 mm3 , P = 0.001). Late lumen loss was 0.22 ± 0.30 mm at 6 months and 0.33 ± 0.44 mm at 18 months. No major adverse cardiac events occurred. At late follow-up (18 months) the scaffold was not visualized by IVUS; therefore the evaluation was restricted to lumen and vessel at that time point. CONCLUSIONS: IVUS serial evaluation of the novel DESolve BRS showed an increase in the device dimensions between baseline and 6 months, with concomitant enlargement of lumen dimensions and effective suppression of neointimal proliferation. At 18 months, no footprint of the scaffold was detected and the initial lumen enlargement was sustained.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Macrolídeos/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Ultrassonografia de Intervenção , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Macrolídeos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...