Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
3.
Commun Med (Lond) ; 2(1): 154, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36473994

RESUMO

BACKGROUND: Conventional preclinical models often miss drug toxicities, meaning the harm these drugs pose to humans is only realized in clinical trials or when they make it to market. This has caused the pharmaceutical industry to waste considerable time and resources developing drugs destined to fail. Organ-on-a-Chip technology has the potential improve success in drug development pipelines, as it can recapitulate organ-level pathophysiology and clinical responses; however, systematic and quantitative evaluations of Organ-Chips' predictive value have not yet been reported. METHODS: 870 Liver-Chips were analyzed to determine their ability to predict drug-induced liver injury caused by small molecules identified as benchmarks by the Innovation and Quality consortium, who has published guidelines defining criteria for qualifying preclinical models. An economic analysis was also performed to measure the value Liver-Chips could offer if they were broadly adopted in supporting toxicity-related decisions as part of preclinical development workflows. RESULTS: Here, we show that the Liver-Chip met the qualification guidelines across a blinded set of 27 known hepatotoxic and non-toxic drugs with a sensitivity of 87% and a specificity of 100%. We also show that this level of performance could generate over $3 billion annually for the pharmaceutical industry through increased small-molecule R&D productivity. CONCLUSIONS: The results of this study show how incorporating predictive Organ-Chips into drug development workflows could substantially improve drug discovery and development, allowing manufacturers to bring safer, more effective medicines to market in less time and at lower costs.


Drug development is lengthy and costly, as it relies on laboratory models that fail to predict human reactions to potential drugs. Because of this, toxic drugs sometimes go on to harm humans when they reach clinical trials or once they are in the marketplace. Organ-on-a-Chip technology involves growing cells on small devices to mimic organs of the body, such as the liver. Organ-Chips could potentially help identify toxicities earlier, but there is limited research into how well they predict these effects compared to conventional models. In this study, we analyzed 870 Liver-Chips to determine how well they predict drug-induced liver injury, a common cause of drug failure, and found that Liver-Chips outperformed conventional models. These results suggest that widespread acceptance of Organ-Chips could decrease drug attrition, help minimize harm to patients, and generate billions in revenue for the pharmaceutical industry.

4.
Biomaterials ; 275: 120957, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34130145

RESUMO

Successful translation of in vivo experimental data to human patients is an unmet need and a bottleneck in the development of effective therapeutics. Organ-on-Chip technology aims to address this need by leveraging recent significant advancements in microfabrication and biomaterials, which enable modeling of organs and their functionality. These microengineered chips offer researchers the possibility to recreate critical elements of native tissue architecture such as in vivo relevant tissue-tissue interface, air-liquid interface, and mechanical forces, including mechanical stretch and fluidic shear stress, which are crucial to recapitulate tissue level functions. Here, we present the development of a new, comprehensive 3D cell-culture system, where we combined our proprietary Organ-Chip technology with the advantages offered by three-dimensional organotypic culture. Leveraging microfabrication techniques, we engineered a flexible chip that consists of a chamber containing an organotypic epithelium, surrounded by two vacuum channels that can be actuated to stretch the hydrogel throughout its thickness. Furthermore, the ceiling of this chamber is a removable lid with a built-in microchannel that can be perfused with liquid or air and removed as needed for direct access to the tissue. The bottom part of this chamber is made from a porous flexible membrane which allows diffusive mass transport to and from the microfluidic channel positioned below the membrane. This additional microfluidic channel can be coated with endothelial cells to emulate a blood vessel and recapitulate endothelial interactions. Our results show that the Open-Top Chip design successfully addresses common challenges associated with the Organs-on-Chip technology, including the capability to incorporate a tissue-specific extracellular matrix gel seeded with primary stromal cells, to reproduce the architectural complexity of tissues by micropatterning the gel, and to extract the gel for H&E staining. We also provide proof-of-concept data on the feasibility of using the system with primary human skin and alveolar epithelial cells.


Assuntos
Células Endoteliais , Dispositivos Lab-On-A-Chip , Endotélio , Humanos , Microfluídica , Microtecnologia
5.
Nat Biomed Eng ; 4(4): 407-420, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31988458

RESUMO

Organ chips can recapitulate organ-level (patho)physiology, yet pharmacokinetic and pharmacodynamic analyses require multi-organ systems linked by vascular perfusion. Here, we describe an 'interrogator' that employs liquid-handling robotics, custom software and an integrated mobile microscope for the automated culture, perfusion, medium addition, fluidic linking, sample collection and in situ microscopy imaging of up to ten organ chips inside a standard tissue-culture incubator. The robotic interrogator maintained the viability and organ-specific functions of eight vascularized, two-channel organ chips (intestine, liver, kidney, heart, lung, skin, blood-brain barrier and brain) for 3 weeks in culture when intermittently fluidically coupled via a common blood substitute through their reservoirs of medium and endothelium-lined vascular channels. We used the robotic interrogator and a physiological multicompartmental reduced-order model of the experimental system to quantitatively predict the distribution of an inulin tracer perfused through the multi-organ human-body-on-chips. The automated culture system enables the imaging of cells in the organ chips and the repeated sampling of both the vascular and interstitial compartments without compromising fluidic coupling.


Assuntos
Técnicas de Cultura de Células/métodos , Dispositivos Lab-On-A-Chip , Microfluídica/métodos , Robótica/métodos , Barreira Hematoencefálica , Encéfalo , Calibragem , Técnicas de Cultura de Células/instrumentação , Desenho de Equipamento , Coração , Humanos , Intestinos , Rim , Fígado , Pulmão , Robótica/instrumentação , Pele
6.
Elife ; 92020 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-31933478

RESUMO

Induction of intestinal drug metabolizing enzymes can complicate the development of new drugs, owing to the potential to cause drug-drug interactions (DDIs) leading to changes in pharmacokinetics, safety and efficacy. The development of a human-relevant model of the adult intestine that accurately predicts CYP450 induction could help address this challenge as species differences preclude extrapolation from animals. Here, we combined organoids and Organs-on-Chips technology to create a human Duodenum Intestine-Chip that emulates intestinal tissue architecture and functions, that are relevant for the study of drug transport, metabolism, and DDI. Duodenum Intestine-Chip demonstrates the polarized cell architecture, intestinal barrier function, presence of specialized cell subpopulations, and in vivo relevant expression, localization, and function of major intestinal drug transporters. Notably, in comparison to Caco-2, it displays improved CYP3A4 expression and induction capability. This model could enable improved in vitro to in vivo extrapolation for better predictions of human pharmacokinetics and risk of DDIs.


Assuntos
Avaliação Pré-Clínica de Medicamentos/instrumentação , Interações Medicamentosas , Duodeno/metabolismo , Subfamília B de Transportador de Cassetes de Ligação de ATP/metabolismo , Animais , Células CACO-2 , Biologia Computacional , Citocromo P-450 CYP3A/metabolismo , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Humanos , Microvilosidades , Técnicas de Cultura de Órgãos , Organoides/metabolismo , Permeabilidade , Transcriptoma
7.
Sci Transl Med ; 11(517)2019 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-31694927

RESUMO

Nonclinical rodent and nonrodent toxicity models used to support clinical trials of candidate drugs may produce discordant results or fail to predict complications in humans, contributing to drug failures in the clinic. Here, we applied microengineered Organs-on-Chips technology to design a rat, dog, and human Liver-Chip containing species-specific primary hepatocytes interfaced with liver sinusoidal endothelial cells, with or without Kupffer cells and hepatic stellate cells, cultured under physiological fluid flow. The Liver-Chip detected diverse phenotypes of liver toxicity, including hepatocellular injury, steatosis, cholestasis, and fibrosis, and species-specific toxicities when treated with tool compounds. A multispecies Liver-Chip may provide a useful platform for prediction of liver toxicity and inform human relevance of liver toxicities detected in animal studies to better determine safety and human risk.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/patologia , Dispositivos Lab-On-A-Chip , Fígado/patologia , Animais , Biomarcadores/metabolismo , Doença Hepática Induzida por Substâncias e Drogas/patologia , Cães , Humanos , Células de Kupffer/metabolismo , Fígado/lesões , Hepatopatias/patologia , Fenótipo , Ratos , Reprodutibilidade dos Testes , Fatores de Risco , Especificidade da Espécie
8.
Integr Biol (Camb) ; 7(12): 1534-46, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26549481

RESUMO

The ability of cells to migrate through tissues and interstitial spaces is an essential factor during development and tissue homeostasis, immune cell mobility, and in various human diseases. Deformation of the nucleus and its associated lamina during 3-D migration is gathering increasing interest in the context of cancer metastasis, with the underlying hypothesis that a softer nucleus, resulting from reduced levels of lamin A/C, may aid tumour spreading. However, current methods to study the migration of cells in confining three dimensional (3-D) environments are limited by their imprecise control over the confinement, physiological relevance, and/or compatibility with high resolution imaging techniques. We describe the design of a polydimethylsiloxane (PDMS) microfluidic device composed of channels with precisely-defined constrictions mimicking physiological environments that enable high resolution imaging of live and fixed cells. The device promotes easy cell loading and rapid, yet long-lasting (>24 hours) chemotactic gradient formation without the need for continuous perfusion. Using this device, we obtained detailed, quantitative measurements of dynamic nuclear deformation as cells migrate through tight spaces, revealing distinct phases of nuclear translocation through the constriction, buckling of the nuclear lamina, and severe intranuclear strain. Furthermore, we found that lamin A/C-deficient cells exhibited increased and more plastic nuclear deformations compared to wild-type cells but only minimal changes in nuclear volume, implying that low lamin A/C levels facilitate migration through constrictions by increasing nuclear deformability rather than compressibility. The integration of our migration devices with high resolution time-lapse imaging provides a powerful new approach to study intracellular mechanics and dynamics in a variety of physiologically-relevant applications, ranging from cancer cell invasion to immune cell recruitment.


Assuntos
Movimento Celular/fisiologia , Núcleo Celular/fisiologia , Dispositivos Lab-On-A-Chip , Animais , Forma do Núcleo Celular/fisiologia , Quimiotaxia/fisiologia , Dimetilpolisiloxanos , Desenho de Equipamento , Células HEK293 , Humanos , Imageamento Tridimensional , Lamina Tipo A/deficiência , Lamina Tipo A/fisiologia , Camundongos , Células NIH 3T3 , Imagem com Lapso de Tempo
9.
Lab Chip ; 13(19): 3956-64, 2013 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-23954953

RESUMO

Polydimethylsiloxane (PDMS) has numerous desirable properties for fabricating microfluidic devices, including optical transparency, flexibility, biocompatibility, and fabrication by casting; however, partitioning of small hydrophobic molecules into the bulk of PDMS hinders industrial acceptance of PDMS microfluidic devices for chemical processing and drug development applications. Here we describe an attractive alternative material that is similar to PDMS in terms of optical transparency, flexibility and castability, but that is also resistant to absorption of small hydrophobic molecules.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Poliuretanos/química , Absorção , Corantes/química , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Interações Hidrofóbicas e Hidrofílicas , Fenômenos Ópticos , Ozônio/química , Poliuretanos/farmacologia , Propriedades de Superfície , Raios Ultravioleta
10.
Curr Protoc Cell Biol ; Chapter 22: Unit22.16, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22968843

RESUMO

The nucleus is the characteristic hallmark of all eukaryotic cells. The physical properties of the nucleus reflect important biological characteristics, such as chromatin organization or nuclear envelope composition; they can also directly affect cellular function, e.g., when cells pass through narrow constrictions, where the stiff nucleus may present a limiting factor. We present two complementary techniques to probe the mechanical properties of the nucleus. In the first, nuclear stiffness relative to the surrounding cytoskeleton is inferred from induced nuclear deformations during strain application to cells on an elastic substrate. In the second approach, nuclear deformability is deduced from the transit time through a perfusion-based microfabricated device with constrictions smaller than the size of the nucleus. These complementary methods, which can be applied to measure nuclear stiffness in large numbers of living adherent or suspended cells, can help identify important changes in nuclear mechanics associated with disease or development.


Assuntos
Biofísica/métodos , Técnicas de Cultura de Células/métodos , Núcleo Celular/química , Interfase , Técnicas Analíticas Microfluídicas/métodos , Fenômenos Biomecânicos , Núcleo Celular/genética , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...