Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38395054

RESUMO

BACKGROUND: We analyzed clinical and radiographic outcomes in patients undergoing anterior lumbar interbody fusions (ALIFs) using a new biomimetic titanium fusion cage (Titan nanoLOCK interbody, Medtronic, Minneapolis, Minnesota, United States). This specialized cage employs precise nanotechnology to stimulate inherent biochemical and cellular osteogenic reactions to the implant, aiming to amplify the rate of fusion. To our knowledge, this is the only study to assess early clinical and radiographic results in ALIFs. METHODS: We conducted a retrospective review of data for patients who underwent single or multilevel ALIF using this implant between October 2016 and April 2021. Indications for treatment were spondylolisthesis, postlaminectomy syndrome, or spinal deformity. Clinical and radiographic outcome data for these patients were collected and assessed. RESULTS: A total of 84 patients were included. The mean clinical follow-up was 36.6 ± 14 months. At 6 months, solid fusion was seen in 97.6% of patients. At 12 months, solid fusion was seen in 98.8% of patients. Significant improvements were seen in patient-reported outcome measures (PROMs; visual analog scale and Oswestry Disability Index) at 6 and 12 months compared with the preoperative scores (p < 0.001). One patient required reoperation for broken pedicle screws 2 days after the ALIF. None of the patients required readmission within 90 days of surgery. No patients experienced an infection. CONCLUSIONS: ALIF using a new titanium interbody fusion implant with a biomimetic surface technology demonstrated high fusion rates (97.6%) as early as 6 months. There was significant improvement in PROMs at 6 and 12 months.

2.
World Neurosurg ; 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37356484

RESUMO

OBJECTIVE: Interbody cages for spinal fusions are primarily constructed from polyetheretherketone or titanium compositions. However, these crude macroscopic materials pose limitations for improving the rates of bony fusions. The authors aimed to compare the fusion rates and postoperative complications in patients who underwent 2-level or 3-or 4-level anterior cervical discectomy and fusion (ACDF) performed with the use of a novel biomimetic surface titanium cage. METHODS: A retrospective multicenter study was conducted that included all patients who underwent multilevel ACDF with this cage between January 2017 and April 2021. Patient demographics and procedure-related, radiographic, and postoperative complication data were collected. RESULTS: A total of 124 patients were identified; 69 (55.6%) had a 3-or 4-level fusion and 55 (44.4%) had a 2-level fusion. The demographics of the 2 groups differed significantly only in terms of age (P = 0.01). At 3 months, a significantly higher solid fusion rate was found for 2-level fusions than 3-or 4-level fusions (83.7% vs. 56.3%, P = 0.004); however, significance was lost at 6-months (98.2% vs. 88.4%, respectively; P = 0.08). No patients required posterior supplemental fixation. Transient dysphagia was the only postoperative complication that was significantly increased in the 3-or 4-level fusion group compared to the 2-level group (27.5% vs. 9.1%, P = 0.02). CONCLUSIONS: Radiographic and clinical outcomes were equivalent in 3-or 4-level and 2-level ACDFs in which these biomimetic surface titanium cages were used. Furthermore, the use of this technology led to high fusion rates with no requirement for posterior supplemental fusions.

3.
Biomed Mater ; 18(3)2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36827708

RESUMO

Osseointegration of titanium-based implants possessing complex macroscale/microscale/mesoscale/nanoscale (multiscale) topographies support a direct and functional connection with native bone tissue by promoting recruitment, attachment and osteoblastic differentiation of bone marrow stromal cells (MSCs). Recent studies show that the MSCs on these surfaces produce factors, including bone morphogenetic protein 2 (BMP2) that can cause MSCs not on the surface to undergo osteoblast differentiation, suggesting they may produce an osteogenic environmentin vivo. This study examined if soluble factors produced by MSCs in contact with titanium-aluminum-vanadium (Ti6Al4V) implants possessing a complex multiscale biomimetic topography are able to induce osteogenesis ectopically. Ti6Al4V disks were grit-blasted and acid-etched to create surfaces possessing macroscale and microscale roughness (MM), micro/meso/nanoscale topography (MN), and macro/micro/meso/nanoscale topography (MMNTM). Polyether-ether-ketone (PEEK) disks were also fabricated by machining to medical-grade specifications. Surface properties were assessed by scanning electron microscopy, contact angle, optical profilometry, and x-ray photoelectron spectroscopy. MSCs were cultured in growth media (GM). Proteins and local factors in their conditioned media (CM) were measured on days 4, 8, 10 and 14: osteocalcin, osteopontin, osteoprotegerin, BMP2, BMP4, and cytokines interleukins 6, 4 and 10 (IL6, IL4, and IL10). CM was collected from D14 MSCs on MMNTMand tissue culture polystyrene (TCPS) and lyophilized. Gel capsules containing active demineralized bone matrix (DBM), heat-inactivated DBM (iDBM), and iDBM + MMN-GM were implanted bilaterally in the gastrocnemius of athymic nude mice (N= 8 capsules/group). Controls included iDBM + GM; iDBM + TCPS-CM from D5 to D10 MSCs; iDBM + MMN-CM from D5 to D10; and iDBM + rhBMP2 (R&D Systems) at a concentration similar to D5-D10 production of MSCs on MMNTMsurfaces. Legs were harvested at 35D. Bone formation was assessed by micro computed tomography and histomorphometry (hematoxylin and eosin staining) with the histology scored according to ASTM 2529-13. DNA was greatest on PEEK at all time points; DNA was lowest on MN at early time points, but increased with time. Cells on PEEK exhibited small changes in differentiation with reduced production of BMP2. Osteoblast differentiation was greatest on the MN and MMNTM, reflecting increased production of BMP2 and BMP4. Pro-regenerative cytokines IL4 and IL10 were increased on Ti-based surfaces; IL6 was reduced compared to PEEK. None of the media from TCPS cultures was osteoinductive. However, MMN-CM exhibited increased bone formation compared to iDBM and iDBM + rhBMP2. Furthermore, exogenous rhBMP2 alone, at the concentration found in MMN-CM collected from D5 to D10 cultures, failed to induce new bone, indicating that other factors in the CM play a critical role in that osteoinductive microenvironment. MSCs cultured on MMNTMTi6Al4V surfaces differentiate and produce an increase in local factors, including BMP2, and the CM from these cultures can induce ectopic bone formation compared to control groups, indicating that the increased bone formation arises from the local response by MSCs to a biomimetic, multiscale surface topography.


Assuntos
Células-Tronco Mesenquimais , Titânio , Animais , Camundongos , Titânio/química , Alumínio/metabolismo , Vanádio/metabolismo , Interleucina-6/metabolismo , Microtomografia por Raio-X , Biomimética , Interleucina-10/metabolismo , Interleucina-4/metabolismo , Camundongos Nus , Osteogênese , Diferenciação Celular , Polietilenoglicóis/química , Citocinas/metabolismo , DNA/metabolismo , Propriedades de Superfície , Osseointegração , Osteoblastos , Células Cultivadas
4.
Biomimetics (Basel) ; 7(2)2022 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-35466263

RESUMO

The use of metallic and polymeric materials for implants has been increasing over the past decade. This trend can be attributed to a variety of factors including a significant increase in basic science research focused on implant material characteristics and how various surface modifications may stimulate osseointegration and, ultimately, fusion. There are many interbody fusion devices and dental implants commercially available; however, detailed information about their surface properties, and the effects that various materials and surface modifications may have on osteogenesis, is lacking in the literature. While the concept of bone-implant osseointegration is a relatively recent addition to the spine fusion literature, there is a comparatively large body of literature related to dental implants. The purpose of this article is to summarize the science of surface modified bone-facing implants, focusing on biomimetic material chemistry and topography of titanium implants, to promote a better understanding of how these characteristics may impact bone formation and osseointegration. This manuscript has the following aspects: highlights the role of titanium and its alloys as potent osteoconductive bioactive materials; explores the importance of biomimetic surface topography at the macro-, micro- and nano-scale; summarizes how material surface design can influence osteogenesis and immune responses in vitro; focuses on the kinds of surface modifications that play a role in the process. Biomimetic surface modifications can be varied across many clinically available biomaterials, and the literature supports the hypothesis that those biomaterial surfaces that exhibit physical properties of bone resorption pits, such as roughness and complex hierarchical structures at the submicron and nanoscale, are more effective in supporting osteoblast differentiation in vitro and osteogenesis in vivo.

5.
Spine J ; 22(2): 296-304, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34343664

RESUMO

BACKGROUND CONTEXT: The transpsoas lateral lumbar interbody fusion (LLIF) technique is an effective alternative to traditional anterior and posterior approaches to the lumbar spine; however, nerve injuries are the most reported postoperative complication. Commonly used strategies to avoid nerve injury (eg, limiting retraction duration) have not been effective in detecting or preventing femoral nerve injuries. PURPOSE: To evaluate the efficacy of emerging intraoperative femoral nerve monitoring techniques and the importance of employing prompt surgical countermeasures when degraded femoral nerve function is detected. STUDY DESIGN/SETTING: We present the results from a retrospective analysis of a multi-center study conducted over the course of 3 years. PATIENT SAMPLE: One hundred and seventy-two lateral lumbar interbody fusion procedures were reviewed. OUTCOME MEASURES: Intraoperative femoral nerve monitoring data was correlated to immediate postoperative neurologic examinations. METHODS: Femoral nerve evoked potentials (FNEP) including saphenous nerve somatosensory evoked potentials (snSSEP) and motor evoked potentials with quadriceps recordings were used to detect evidence of degraded femoral nerve function during the time of surgical retraction. RESULTS: In 89% (n=153) of the surgeries, there were no surgeon alerts as the FNEP response amplitudes remained relatively unchanged throughout the surgery (negative group). The positive group included 11% of the cases (n=19) where the surgeon was alerted to a deterioration of the FNEP amplitudes during surgical retraction. Prompt surgical countermeasures to an FNEP alert included loosening, adjusting, or removing surgical retraction, and/or requesting an increase in blood pressure from the anesthesiologist. All the cases where prompt surgical countermeasures were employed resulted in recovery of the degraded FNEP amplitudes and no postoperative femoral nerve injuries. In two cases, the surgeons were given verbal alerts of degraded FNEPs but did not employ prompt surgical countermeasures. In both cases, the degraded FNEP amplitudes did not recover by the time of surgical closure, and both patients exhibited postoperative signs of sensorimotor femoral nerve injury including anterior thigh numbness and weakened knee extension. CONCLUSIONS: Multimodal femoral nerve monitoring can provide surgeons with a timely alert to hyperacute femoral nerve conduction failure, enabling prompt surgical countermeasures to be employed that can mitigate or avoid femoral nerve injury. Our data also suggests that the common strategy of limiting retraction duration may not be effective in preventing iatrogenic femoral nerve injuries.


Assuntos
Nervo Femoral , Fusão Vertebral , Potencial Evocado Motor/fisiologia , Nervo Femoral/lesões , Humanos , Vértebras Lombares/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
6.
Am J Orthop (Belle Mead NJ) ; 44(2): 86-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25658078

RESUMO

The accuracy of using computed tomography (CT) to assess interbody fusion in patients with titanium implants has been questioned in the past. Radiologists have reported difficulty assessing fusion bone quality because of metal artifact and small graft windows. A new titanium interbody implant with a large footprint and a wide graft aperture has been developed. We conducted a study to determine the interobserver reliability of using CT to assess radiographic fusion variables with the new titanium interbody device. Patients underwent anterior lumbar interbody fusion with the same titanium interbody implant. Reconstructed CT images were obtained randomly at 6, 9, or 12 months. Two independent radiologists reviewed the scans. Interobserver reliability was calculated using the κ statistic. Fifty-six spinal fusion levels (33 patients) were analyzed. The radiologists agreed on 345 of the 392 fusion data points reviewed (κ = .88). Agreement for solid fusion formation was 0.77. This interbody device demonstrated minimal artifact and minimal subsidence, and trabecular bone was easily identified throughout the implant in the vast majority of cases reviewed. High interobserver agreement was noted across all radiographic variables assessed.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Pseudoartrose/diagnóstico por imagem , Fusão Vertebral , Adulto , Idoso , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Próteses e Implantes , Implantação de Prótese/efeitos adversos , Pseudoartrose/etiologia , Fusão Vertebral/efeitos adversos , Titânio , Tomografia Computadorizada por Raios X , Adulto Jovem
7.
Spine (Phila Pa 1976) ; 40(6): 399-404, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25584952

RESUMO

STUDY DESIGN: An in vitro study examining factors produced by human mesenchymal stem cells on spine implant materials. OBJECTIVE: The aim of this study was to examine whether the inflammatory microenvironment generated by cells on titanium-aluminum-vanadium (Ti-alloy, TiAlV) surfaces is affected by surface microtexture and whether it differs from that generated on poly-ether-ether-ketone (PEEK). SUMMARY OF BACKGROUND DATA: Histologically, implants fabricated from PEEK have a fibrous connective tissue surface interface whereas Ti-alloy implants demonstrate close approximation with surrounding bone. Ti-alloy surfaces with complex micron/submicron scale roughness promote osteoblastic differentiation and foster a specific cellular environment that favors bone formation whereas PEEK favors fibrous tissue formation. METHODS: Human mesenchymal stem cells were cultured on tissue culture polystyrene, PEEK, smooth TiAlV, or macro-/micro-/nano-textured rough TiAlV (mmnTiAlV) disks. Osteoblastic differentiation and secreted inflammatory interleukins were assessed after 7 days. Fold changes in mRNAs for inflammation, necrosis, DNA damage, or apoptosis with respect to tissue culture polystyrene were measured by low-density polymerase chain reaction array. Data were analyzed by analysis of variance, followed by Bonferroni's correction of Student's t-test. RESULTS: Cells on PEEK upregulated mRNAs for chemokine ligand-2, interleukin (IL) 1ß, IL6, IL8, and tumor necrosis factor. Cells grown on the mmnTiAlV had an 8-fold reduction in mRNAs for toll-like receptor-4. Cells grown on mmnTiAlV had reduced levels of proinflammatory interleukins. Cells on PEEK had higher mRNAs for factors strongly associated with cell death/apoptosis, whereas cells on mmnTiAlV exhibited reduced cytokine factor levels. All results were significant (P < 0.05). CONCLUSION: These results suggest that fibrous tissue around PEEK implants may be due to several factors: reduced osteoblastic differentiation of progenitor cells and production of an inflammatory environment that favors cell death via apoptosis and necrosis. Ti alloy surfaces with complex macro/micro/nanoscale roughness promote osteoblastic differentiation and foster a specific cellular environment that favors bone formation. LEVEL OF EVIDENCE: N/A.


Assuntos
Materiais Biocompatíveis/farmacologia , Osso e Ossos/patologia , Interleucinas/metabolismo , Cetonas/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Polietilenoglicóis/farmacologia , Titânio/farmacologia , Ligas , Apoptose/efeitos dos fármacos , Benzofenonas , Materiais Biocompatíveis/química , Osso e Ossos/efeitos dos fármacos , Células Cultivadas , Microambiente Celular , Dano ao DNA , Fibrose/induzido quimicamente , Fibrose/patologia , Humanos , Interleucinas/análise , Cetonas/efeitos adversos , Cetonas/química , Células-Tronco Mesenquimais/citologia , Osteogênese/efeitos dos fármacos , Polietilenoglicóis/efeitos adversos , Polietilenoglicóis/química , Polímeros , Propriedades de Superfície , Titânio/química
10.
Spine J ; 13(11): 1563-70, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23684238

RESUMO

BACKGROUND CONTEXT: Polyether-ether-ketone (PEEK) and titanium-aluminum-vanadium (titanium alloy) are used frequently in lumbar spine interbody fusion. Osteoblasts cultured on microstructured titanium generate an environment characterized by increased angiogenic factors and factors that inhibit osteoclast activity mediated by integrin α2ß1 signaling. It is not known if this is also true of osteoblasts on titanium alloy or PEEK. PURPOSE: The purpose of this study was to determine if osteoblasts generate an environment that supports angiogenesis and reduces osteoclastic activity when grown on smooth titanium alloy, rough titanium alloy, or PEEK. STUDY DESIGN: This in vitro study compared angiogenic factor production and integrin gene expression of human osteoblast-like MG63 cells cultured on PEEK or titanium-aluminum-vanadium (titanium alloy). METHODS: MG63 cells were grown on PEEK, smooth titanium alloy, or rough titanium alloy. Osteogenic microenvironment was characterized by secretion of osteoprotegerin and transforming growth factor beta-1 (TGF-ß1), which inhibit osteoclast activity and angiogenic factors including vascular endothelial growth factor A (VEGF-A), fibroblast growth factor 2 (FGF-2), and angiopoietin-1 (ANG-1). Expression of integrins, transmembrane extracellular matrix recognition proteins, was measured by real-time polymerase chain reaction. RESULTS: Culture on titanium alloy stimulated osteoprotegerin, TGF-ß1, VEGF-A, FGF-2, and angiopoietin-1 production, and levels were greater on rough titanium alloy than on smooth titanium alloy. All factors measured were significantly lower on PEEK than on smooth or rough titanium alloy. Culture on titanium alloy stimulated expression of messenger RNA for integrins that recognize Type I collagen in comparison with PEEK. CONCLUSIONS: Rough titanium alloy stimulated cells to create an osteogenic-angiogenic microenvironment. The osteogenic-angiogenic responses to titanium alloy were greater than PEEK and greater on rough titanium alloy than on smooth titanium alloy. Surface features regulated expression of integrins important in collagen recognition. These factors may increase bone formation, enhance integration, and improve implant stability in interbody spinal fusions.


Assuntos
Angiopoietina-1/metabolismo , Fator 2 de Crescimento de Fibroblastos/metabolismo , Cetonas/farmacologia , Osteoblastos/efeitos dos fármacos , Polietilenoglicóis/farmacologia , Titânio/farmacologia , Fator A de Crescimento do Endotélio Vascular/metabolismo , Ligas/farmacologia , Benzofenonas , Materiais Biocompatíveis , Linhagem Celular , Células Cultivadas , Humanos , Osteoblastos/metabolismo , Osteoprotegerina/metabolismo , Polímeros , Fator de Crescimento Transformador beta1/metabolismo
11.
Spine (Phila Pa 1976) ; 38(7): E409-22, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23334400

RESUMO

STUDY DESIGN: Systematic literature review. OBJECTIVE: To categorize published evidence systematically for lumbar fusion for chronic low back pain (LBP) in order to provide an updated and comprehensive analysis of the clinical outcomes. SUMMARY OF BACKGROUND DATA: Despite a large number of publications of outcomes of spinal fusion surgery for chronic LBP, there is little consensus on efficacy. METHODS: A MEDLINE and Cochrane database search was performed to identify published articles reporting on validated patient-reported clinical outcomes measures (2 or more of visual analogue scale, Oswestry Disability Index, Short Form [36] Health Survey [SF-36] PCS, and patient satisfaction) with minimum 12 months of follow-up after lumbar fusion surgery in adult patients with LBP due to degenerative disc disease. Twenty-six total articles were identified and stratified by level of evidence: 18 level 1 (6 studies of surgery vs. nonoperative treatment, 12 studies of alternative surgical procedures), 2 level 2, 2 level 3, and 4 level 4 (2 prospective, 2 retrospective). Weighted averages of each outcomes measure were computed and compared with established minimal clinically important difference values. RESULTS: Fusion cohorts included a total of 3060 patients. The weighted average improvement in visual analogue scale back pain was 36.8/100 (standard deviation [SD], 14.8); in Oswestry Disability Index 22.2 (SD, 14.1); in SF-36 Physical Component Scale 12.5 (SD, 4.3). Patient satisfaction averaged 71.1% (SD, 5.2%) across studies. Radiographical fusion rates averaged 89.1% (SD, 13.5%), and reoperation rates 12.5% (SD, 12.4%) overall, 9.2% (SD, 7.5%) at the index level. The results of the collective studies did not differ statistically in any of the outcome measures based on level of evidence (analysis of variance, P > 0.05). CONCLUSION: The body of literature supports fusion surgery as a viable treatment option for reducing pain and improving function in patients with chronic LBP refractory to nonsurgical care when a diagnosis of disc degeneration can be made.


Assuntos
Dor Crônica/cirurgia , Deslocamento do Disco Intervertebral/cirurgia , Dor Lombar/cirurgia , Vértebras Lombares/cirurgia , Fusão Vertebral , Adulto , Idoso , Dor Crônica/etiologia , Ensaios Clínicos como Assunto/estatística & dados numéricos , Estudos de Coortes , Avaliação da Deficiência , Medicina Baseada em Evidências , Seguimentos , Humanos , Deslocamento do Disco Intervertebral/complicações , Dor Lombar/etiologia , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Índice de Gravidade de Doença , Fusão Vertebral/psicologia , Fusão Vertebral/estatística & dados numéricos , Resultado do Tratamento
13.
Spine (Phila Pa 1976) ; 36(25): 2158-67, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-21325990

RESUMO

STUDY DESIGN: Prospective, longitudinal cohort study. OBJECTIVE: To examine the incidence of bone morphogenetic protein (BMP)-2 antibody formation in lumbar spine applications and to determine the clinical significance of an antibody response. SUMMARY OF BACKGROUND DATA: Immune responses can affect the safety and efficacy profile of recombinant proteins. Type, incidence, and time course of antibody formation were evaluated in clinical studies investigating recombinant human bone morphogenetic protein (rhBMP)-2 in spinal arthrodesis. METHODS: Analysis of antibody formation to BMP-2, bovine collagen, and human collagen was performed after three prospective clinical studies investigating rhBMP-2 in single-level lumbar spinal arthrodesis. Two studies investigated rhBMP-2 applied to an absorbable collagen sponge at 1.5 mg/cm3 in lumbar interbody fusion (n=449); one study investigated rhBMP-2 applied to a ceramic and collagen compression-resistant matrix at 2.0 mg/cm3 in instrumented posterolateral fusion (n=239). Control patients received iliac crest bone graft (n=360). Two validated enzyme-linked immunosorbent assays were used to test for BMP-2 antibodies. Neutralizing antibodies were assessed using a cell bioassay. The incidence of antibodies to bovine and human collagen was determined. Radiographic and clinical outcome data were assessed to determine whether antibodies were correlated to patient outcomes. RESULTS: BMP-2 antibody rates ranged from 0.8% to 6.4% in rhBMP-2 patients and from 0% to 2.3% in control patients. Formation of BMP-2 antibodies peaked within the first 3 months and returned toward baseline values by 12 months. No neutralizing antibodies were detected. Bovine collagen antibody rates ranged from 12.7% to 18.8% in the rhBMP-2 patients and from 12.9% to 21.2% in the control patients. No antibodies to human collagen were detected. Adverse event rates were similar in antibody-positive and antibody-negative patients. BMP-2 antibodies did not affect bridging bone rates. CONCLUSION: Formation of anti-BMP-2 antibodies was low and transient. No neutralizing antibodies were observed. Formation of antibodies did not affect fusion success or appear to have clinical sequelae.


Assuntos
Anticorpos/sangue , Proteína Morfogenética Óssea 2/imunologia , Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Fator de Crescimento Transformador beta/imunologia , Animais , Anticorpos Neutralizantes/sangue , Proteína Morfogenética Óssea 2/efeitos adversos , Proteína Morfogenética Óssea 2/uso terapêutico , Bovinos , Colágeno Tipo I/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Seguimentos , Humanos , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/sangue , Degeneração do Disco Intervertebral/imunologia , Degeneração do Disco Intervertebral/cirurgia , Estudos Longitudinais , Vértebras Lombares/patologia , Masculino , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/imunologia , Proteínas Recombinantes/uso terapêutico , Fatores de Tempo , Fator de Crescimento Transformador beta/efeitos adversos , Fator de Crescimento Transformador beta/uso terapêutico
14.
J Am Acad Orthop Surg ; 15(10): 596-606, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17916783

RESUMO

Whiplash is neck pain experienced as a result of a motor vehicle collision or similar trauma. Following a motor vehicle collision, 15% to 40% of patients with acute neck pain develop chronic neck pain. The cervical facet joint is the most common source of chronic neck pain after whiplash injury, followed by disk pain. Some patients experience pain from both structures. Initial management recommendations need not be directed toward an exact structural cause, but treatment includes advising the patient to remain active, prescribing medications when necessary, and providing advice regarding the generally favorable outcome. When neck pain persists, the physician should recommend medial branch blocks of the dorsal rami of the spinal nerves that supply the putative painful facet joint or joints; this is done to determine whether the facet joints are the cause of pain. When significant relief occurs on two occasions, radiofrequency neurotomy typically provides substantial relief for approximately 8 to 12 months and can be repeated indefinitely as needed. Occasionally, long-term treatment with medication may be indicated. Anterior cervical diskectomy and fusion is necessary on rare occasions.


Assuntos
Traumatismos em Chicotada/terapia , Adulto , Doença Crônica , Medicina Baseada em Evidências , Feminino , Humanos , Cervicalgia/etiologia , Traumatismos em Chicotada/complicações , Traumatismos em Chicotada/fisiopatologia , Traumatismos em Chicotada/psicologia
15.
Spine J ; 7(3): 301-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17482113

RESUMO

BACKGROUND CONTEXT: Recombinant human bone morphogenetic protein-2 (rhBMP-2) is an osteoinductive protein approved for use in the anterior lumbar interspace. High fusion rates with rhBMP-2 have been reported with threaded interbody allograft dowels. There may be a clinical benefit for the patient by adding rhBMP-2 to the allograft. PURPOSE: To compare the fusion rates and clinical outcomes of patients treated with allograft interbody fusions with and without the addition of rhBMP-2. STUDY DESIGN: Prospective consecutive patient enrollment with minimum 24-month follow-up. PATIENT SAMPLE: Seventy-five patients with lumbar interbody fusions at 1-3 spinal segments. OUTCOMES MEASURES: Clinical: Numerical Rating Scale (NRS) and Oswestry Disability Index (ODI). Radiographic: X-ray and computed tomographic scan analysis using the Molinari-Bridwell fusion scale. METHODS: Seventy-five patients scheduled for lumbar fusion were enrolled sequentially. Group 1: 30 patients had anterior interbody allografts alone. Group 2: 45 patients had anterior interbody allograft filled with rhBMP-2. All cases had posterior pedicle screw instrumentation. A total of 165 surgical levels (62 allograft alone/103 allograft+BMP) were included. Fusion data and clinical outcomes were collected for a minimum of 2 years after surgery. RESULTS: Statistically higher fusion rates were observed in the patients with BMP at all time points compared with allograft alone. Group 2 (+ BMP) fusion rates were 94%, 100%, and 100% at 6, 12, and 24 months after surgery. Group 1 (-BMP) fusion rates were 66%, 84%, and 89% at the same time intervals. Clinical outcomes were significantly improved in Group 2 compared with Group 1 at 6 months. There were no revisions (0%) in the BMP group and 4 revision fusion surgeries (13%) in the allograft group. No untoward effects were attributable to the rhBMP-2. CONCLUSIONS: Our study confirms the efficacy of an innovative lumbar fusion technique: an interbody femoral ring allograft, combined with an osteoinductive stimulant (rhBMP-2), protected by pedicle screws. This combination of a structural interbody allograft with rhBMP-2 eliminates the insult of iliac crest harvest, allows for reliable radiographic analysis, and results in successful fusion formation in 100% of the cases in this study.


Assuntos
Proteínas Morfogenéticas Ósseas/uso terapêutico , Transplante Ósseo/métodos , Fusão Vertebral/métodos , Fator de Crescimento Transformador beta/uso terapêutico , Adulto , Proteína Morfogenética Óssea 2 , Parafusos Ósseos , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Proteínas Recombinantes/uso terapêutico , Transplante Homólogo , Resultado do Tratamento
16.
Spine (Phila Pa 1976) ; 27(22): 2555-62; discussion 2563, 2002 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-12435993

RESUMO

STUDY DESIGN: Peer-reviewed literature was reviewed and summarized. OBJECTIVE: To synthesize the indications and published outcomes of reconstructive lumbar spine surgery for the treatment of chronic pain of spinal origin. METHODS: A literature review was conducted. RESULTS: The most common indication for reconstructive lumbar surgery is pain that is refractory to nonsurgical treatment. Lumbar fusion has been shown to improve symptoms in carefully selected patients with incapacitating pain. CONCLUSIONS: A successful arthrodesis is the fundamental surgical goal for patients with chronic pain of spinal origin. However, a successful fusion does not always correlate with a successful clinical result.


Assuntos
Dor Intratável/cirurgia , Procedimentos de Cirurgia Plástica , Doenças da Coluna Vertebral/cirurgia , Doença Crônica , Humanos , Vértebras Lombares/cirurgia , Região Lombossacral , Dor Intratável/etiologia , Procedimentos de Cirurgia Plástica/efeitos adversos , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Doenças da Coluna Vertebral/complicações , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Resultado do Tratamento
17.
Pain Med ; 3(1): 18-22, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15102214

RESUMO

BACKGROUND CONTEXT: Patients who do not improve after lumbar surgery may be given the nonspecific label of "failed back surgery syndrome (FBSS)." Since 1981, there has not been a quantitative assessment of the etiologies of FBSS despite major improvements in surgical techniques and diagnostic testing. PURPOSE: To define the causes of FBSS seen in a referral-based spine center. STUDY DESIGN AND METHODS: Retrospective review of 181 consecutive charts of patients seen at a single spine center because of continued pain after lumbar surgery performed elsewhere. Evaluation was individualized based on history and physical examination and included x-rays, CT scans, MRI, selective nerve root injections, discography, and psychiatric evaluation. PATIENT SAMPLE: There were 101 men and 80 women; mean age was 47 years. There were 118 patients with one prior surgery, 52 with two, 6 with three, and 5 with four. Mean interval from the last prior surgery to the first clinic visit was 33 months. RESULTS: A predominant diagnosis could be established in 170 of 181 (94%) patients, and included foraminal stenosis (29%), painful disc(s) (17%), pseudarthrosis (14%), neuropathic pain (9%), instability (5%), and psychological problems (3%). CONCLUSION: We were able to establish a predominant diagnosis in 94% of our patients. Foraminal stenosis remains the leading cause of FBSS, but painful discs are also common. Recurrent disc herniation is seen less often than in the past, and there is increased recognition of neuropathic pain. Knowledge of the potential causes of FBSS leads to a more efficient and cost-effective evaluation of these patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...