Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Radiat Prot Dosimetry ; 195(3-4): 177-187, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33778892

RESUMO

Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the increased use of CT during the last decades, efforts to minimise patient exposure, while maintaining sufficient or improved image quality, have led to the development of model-based iterative reconstruction (MBIR) algorithms from several vendors. The usefulness of the advanced modeled iterative reconstruction (ADMIRE) (Siemens Healthineers) MBIR in abdominal CT is reviewed and its noise suppression and/or dose reduction possibilities explored. Quantitative and qualitative methods with phantom and human subjects were used. Assessment of the quality of phantom images will not always correlate positively with those of patient images, particularly at the higher strength of the ADMIRE algorithm. With few exceptions, ADMIRE Strength 3 typically allows for substantial noise reduction compared to FBP and hence to significant (≈30%) patient dose reductions. The size of the dose reductions depends on the diagnostic task.


Assuntos
Redução da Medicação , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
2.
Sci Rep ; 10(1): 17986, 2020 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-33093605

RESUMO

Malignant gliomas are primary brain tumours with an infiltrative growth pattern, often with contrast enhancement on magnetic resonance imaging (MRI). However, it is well known that tumour infiltration extends beyond the visible contrast enhancement. The aim of this study was to investigate if there is contrast enhancement not detected visually in the peritumoral oedema of malignant gliomas by using relaxometry with synthetic MRI. 25 patients who had brain tumours with a radiological appearance of malignant glioma were prospectively included. A quantitative MR-sequence measuring longitudinal relaxation (R1), transverse relaxation (R2) and proton density (PD), was added to the standard MRI protocol before surgery. Five patients were excluded, and in 20 patients, synthetic MR images were created from the quantitative scans. Manual regions of interest (ROIs) outlined the visibly contrast-enhancing border of the tumours and the peritumoral area. Contrast enhancement was quantified by subtraction of native images from post GD-images, creating an R1-difference-map. The quantitative R1-difference-maps showed significant contrast enhancement in the peritumoral area (0.047) compared to normal appearing white matter (0.032), p = 0.048. Relaxometry detects contrast enhancement in the peritumoral area of malignant gliomas. This could represent infiltrative tumour growth.


Assuntos
Neoplasias Encefálicas/diagnóstico , Meios de Contraste/metabolismo , Edema/diagnóstico , Glioma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Neoplasias Encefálicas/metabolismo , Edema/metabolismo , Feminino , Glioma/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade
3.
AJNR Am J Neuroradiol ; 37(1): 94-100, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26471751

RESUMO

BACKGROUND AND PURPOSE: Contrast-enhancing MS lesions are important markers of active inflammation in the diagnostic work-up of MS and in disease monitoring with MR imaging. Because intravenous contrast agents involve an expense and a potential risk of adverse events, it would be desirable to identify active lesions without using a contrast agent. The purpose of this study was to evaluate whether pre-contrast injection tissue-relaxation rates and proton density of MS lesions, by using a new quantitative MR imaging sequence, can identify active lesions. MATERIALS AND METHODS: Forty-four patients with a clinical suspicion of MS were studied. MR imaging with a standard clinical MS protocol and a quantitative MR imaging sequence was performed at inclusion (baseline) and after 1 year. ROIs were placed in MS lesions, classified as nonenhancing or enhancing. Longitudinal and transverse relaxation rates, as well as proton density were obtained from the quantitative MR imaging sequence. Statistical analyses of ROI values were performed by using a mixed linear model, logistic regression, and receiver operating characteristic analysis. RESULTS: Enhancing lesions had a significantly (P < .001) higher mean longitudinal relaxation rate (1.22 ± 0.36 versus 0.89 ± 0.24), a higher mean transverse relaxation rate (9.8 ± 2.6 versus 7.4 ± 1.9), and a lower mean proton density (77 ± 11.2 versus 90 ± 8.4) than nonenhancing lesions. An area under the receiver operating characteristic curve value of 0.832 was obtained. CONCLUSIONS: Contrast-enhancing MS lesions often have proton density and relaxation times that differ from those in nonenhancing lesions, with lower proton density and shorter relaxation times in enhancing lesions compared with nonenhancing lesions.


Assuntos
Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste/administração & dosagem , Feminino , Seguimentos , Gadolínio DTPA/administração & dosagem , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Esclerose Múltipla Recidivante-Remitente/diagnóstico , Adulto Jovem
4.
Dentomaxillofac Radiol ; 43(8): 20140196, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25168811

RESUMO

OBJECTIVES: The aim of this study was to evaluate how imaging parameters at clinical dental CBCT affect the accuracy in quantifying trabecular bone structures, contrast-to-noise ratio (CNR) and radiation dose. METHODS: 15 radius samples were examined using CBCT (Accuitomo FPD; J. Morita Mfg., Kyoto, Japan). Nine imaging protocols were used, differing in current, voltage, rotation degree, voxel size, imaging area and rotation time. Radiation doses were measured using a kerma area product-meter. After segmentation, six bone structure parameters and CNRs were quantified. Micro-CT (µCT) images with an isotropic resolution of 20 µm were used as a gold standard. RESULTS: Structure parameters obtained by CBCT were strongly correlated to those by µCT, with correlation coefficients >0.90 for all studied parameters. Bone volume and trabecular thickness were not affected by changes in imaging parameters. Increased tube current from 5 to 8 mA, decreased isotropic voxel size from 125 to 80 µm and decreased rotation angle from 360° to 180° affected correlations for trabecular termini negatively. Decreasing rotation degree also weakened correlations for trabecular separation and trabecular number at 80 µm voxel size. Changes in the rotation degree and tube current affected CNR significantly. The radiation dose varied between 269 and 1153 mGy cm(2). CONCLUSIONS: Trabecular bone structure can be accurately quantified by clinical dental CBCT in vitro, and the obtained structure parameters are strongly related to those obtained by µCT. A fair CNR and strong correlations can be obtained with a low radiation dose, indicating the possibility for monitoring trabecular bone structure also in vivo.

5.
Br J Radiol ; 86(1021): 31197714, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22723511

RESUMO

OBJECTIVES: To propose a method to study the effect of exposure settings on image quality and to estimate the potential for dose reduction when introducing dose-reducing measures. METHODS: Using the framework of visual grading regression (VGR), a log(mAs) term is included in the ordinal logistic regression equation, so that the effect of reducing the dose can be quantitatively related to the effect of adding post-processing. In the ordinal logistic regression, patient and observer identity are treated as random effects using generalised linear latent and mixed models. The potential dose reduction is then estimated from the regression coefficients. The method was applied in a single-image study of coronary CT angiography (CTA) to evaluate two-dimensional (2D) adaptive filters, and in an image-pair study of abdominal CT to evaluate 2D and three-dimensional (3D) adaptive filters. RESULTS: For five image quality criteria in coronary CTA, dose reductions of 16-26% were predicted when adding 2D filtering. Using five image quality criteria for abdominal CT, it was estimated that 2D filtering permits doses were reduced by 32-41%, and 3D filtering by 42-51%. CONCLUSIONS: VGR including a log(mAs) term can be used for predictions of potential dose reduction that may be useful for guiding researchers in designing subsequent studies evaluating diagnostic value. With appropriate statistical analysis, it is possible to obtain direct numerical estimates of the dose-reducing potential of novel acquisition, reconstruction or post-processing techniques.


Assuntos
Doses de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Variações Dependentes do Observador , Lesões por Radiação/etiologia , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/efeitos adversos
6.
Br J Radiol ; 86(1021): 20110784, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23239690

RESUMO

Objectives To propose a method to study the effect of exposure settings on image quality and to estimate the potential for dose reduction when introducing dose-reducing measures. Methods Using the framework of visual grading regression (VGR), a log(mAs) term is included in the ordinal logistic regression equation, so that the effect of reducing the dose can be quantitatively related to the effect of adding post-processing. In the ordinal logistic regression, patient and observer identity are treated as random effects using generalised linear latent and mixed models. The potential dose reduction is then estimated from the regression coefficients. The method was applied in a single-image study of coronary CT angiography (CTA) to evaluate two-dimensional (2D) adaptive filters, and in an image-pair study of abdominal CT to evaluate 2D and three-dimensional (3D) adaptive filters. Results For five image quality criteria in coronary CTA, dose reductions of 16-26% were predicted when adding 2D filtering. Using five image quality criteria for abdominal CT, it was estimated that 2D filtering permits doses were reduced by 32-41%, and 3D filtering by 42-51%. Conclusions VGR including a log(mAs) term can be used for predictions of potential dose reduction that may be useful for guiding researchers in designing subsequent studies evaluating diagnostic value. With appropriate statistical analysis, it is possible to obtain direct numerical estimates of the dose-reducing potential of novel acquisition, reconstruction or post-processing techniques.


Assuntos
Algoritmos , Doses de Radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Lesões por Radiação/etiologia , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/efeitos adversos
7.
Acta Radiol ; 53(10): 1158-63, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23024181

RESUMO

BACKGROUND: Conventional magnetic resonance imaging (MRI) has relatively long scan times for routine examinations, and the signal intensity of the images is related to the specific MR scanner settings. Due to scanner imperfections and automatic optimizations, it is impossible to compare images in terms of absolute image intensity. Synthetic MRI, a method to generate conventional images based on MR quantification, potentially both decreases examination time and enables quantitative measurements. PURPOSE: To evaluate synthetic MRI of the brain in a clinical setting by assessment of the contrast, the contrast-to-noise ratio (CNR), and the diagnostic quality compared with conventional MR images. MATERIAL AND METHODS: Twenty-two patients had synthetic imaging added to their clinical MR examination. In each patient, 12 regions of interest were placed in the brain images to measure contrast and CNR. Furthermore, general image quality, probable diagnosis, and lesion conspicuity were investigated. RESULTS: Synthetic T1-weighted turbo spin echo and T2-weighted turbo spin echo images had higher contrast but also a higher level of noise, resulting in a similar CNR compared with conventional images. Synthetic T2-weighted FLAIR images had lower contrast and a higher level of noise, which led to a lower CNR. Synthetic images were generally assessed to be of inferior image quality, but agreed with the clinical diagnosis to the same extent as the conventional images. Lesion conspicuity was higher in the synthetic T1-weighted images, which also had a better agreement with the clinical diagnoses than the conventional T1-weighted images. CONCLUSION: Synthetic MR can potentially shorten the MR examination time. Even though the image quality is perceived to be inferior, synthetic images agreed with the clinical diagnosis to the same extent as the conventional images in this study.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/patologia , Humanos , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Adulto Jovem
8.
Eur Radiol ; 22(3): 642-53, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21984449

RESUMO

OBJECTIVES: To develop and evaluate a procedure for quantifying the hepatocyte-specific uptake of Gd-BOPTA and Gd-EOB-DTPA using dynamic contrast-enhanced (DCE) MRI. METHODS: Ten healthy volunteers were prospectively recruited and 21 patients with suspected hepatobiliary disease were retrospectively evaluated. All subjects were examined with DCE-MRI using 0.025 mmol/kg of Gd-EOB-DTPA. The healthy volunteers underwent an additional examination using 0.05 mmol/kg of Gd-BOPTA. The signal intensities (SI) of liver and spleen parenchyma were obtained from unenhanced and enhanced acquisitions. Using pharmacokinetic models of the liver and spleen, and an SI rescaling procedure, a hepatic uptake rate, K (Hep), estimate was derived. The K (Hep) values for Gd-EOB-DTPA were then studied in relation to those for Gd-BOPTA and to a clinical classification of the patient's hepatobiliary dysfunction. RESULTS: K (Hep) estimated using Gd-EOB-DTPA showed a significant Pearson correlation with K (Hep) estimated using Gd-BOPTA (r = 0.64; P < 0.05) in healthy subjects. Patients with impaired hepatobiliary function had significantly lower K (Hep) than patients with normal hepatobiliary function (K (Hep) = 0.09 ± 0.05 min(-1) versus K (Hep) = 0.24 ± 0.10 min(-1); P < 0.01). CONCLUSIONS: A new procedure for quantifying the hepatocyte-specific uptake of T (1)-enhancing contrast agent was demonstrated and used to show that impaired hepatobiliary function severely influences the hepatic uptake of Gd-EOB-DTPA. KEY POINTS: • The liver uptake of contrast agents may be measured with standard clinical MRI. • Calculation of liver contrast agent uptake is improved by considering splenic uptake. • Liver function affects the uptake of the liver-specific contrast agent Gd-EOB-DTPA. • Hepatic uptake of two contrast agents (Gd-EOB-DTPA, Gd-BOPTA) is correlated in healthy individuals. • This method can be useful for determining liver function, e.g. before hepatic surgery.


Assuntos
Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Hepatopatias/diagnóstico , Hepatopatias/metabolismo , Fígado/metabolismo , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/farmacocinética , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Meglumina/farmacocinética , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Estudos Retrospectivos , Baço/metabolismo , Resultado do Tratamento
9.
Br J Radiol ; 83(993): 767-75, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20223912

RESUMO

For visual grading experiments, which are an easy and increasingly popular way of studying image quality, hitherto used data analysis methods are often inadequate. Visual grading analysis makes assumptions that are not statistically appropriate for ordinal data, and visual grading characteristic curves are difficult to apply in more complex experimental designs. The approach proposed in this paper, visual grading regression (VGR), consists of an established statistical technique, ordinal logistic regression, applied to data from single-image and image-pair experiments with visual grading scores selected on an ordinal scale. The approach is applicable for situations in which, for example, the effects of the choice of imaging equipment and post-processing method are to be studied simultaneously, while controlling for potentially confounding variables such as patient and observer identity. The analysis can be performed with standard statistical software packages using straightforward coding of the data. We conclude that the proposed statistical technique is useful in a wide range of visual grading studies.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiografia/métodos , Interpretação Estatística de Dados , Humanos , Modelos Logísticos , Curva ROC , Radiografia/normas , Estatísticas não Paramétricas
10.
Eur J Radiol ; 75(2): e124-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20219308

RESUMO

PURPOSE: Dual Energy Computed Tomography (DECT) may provide additional information about the chemical composition of tissues compared to examination with a single X-ray energy. The aim of this in vitro study was to test whether combining two energies may significantly improve the detection of soft tissue components commonly present in arterial plaques. METHODS: Tissue samples of myocardial and psoas muscle, venous and arterial thrombus as well as fat from different locations were scanned using a SOMATOM Definition Dual Source CT system (Siemens AG, Medical Solutions, Forchheim, Germany) with simultaneous tube voltages of 140 and 80 kV. The attenuation (Hounsfield units, HU) at 80 and 140 kV was measured in representative regions of interest, and the association between measured HU values and tissue types was tested with logistic regression. RESULTS: The combination of two energy levels (80 and 140 kV) significantly improved (p<0.001) the ability to correctly classify venous thrombus vs arterial thrombus, myocardium or psoas; arterial thrombus vs myocardium or psoas; myocardium vs psoas; as well as the differentiation between fat tissue from various locations. Single energy alone was sufficient for distinguishing fat from other tissues. CONCLUSION: DECT offers significantly improved in vitro differentiation between soft tissues occurring in plaques. If this corresponds to better tissue discrimination in vivo needs to be clarified in future studies.


Assuntos
Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Tecido Adiposo/diagnóstico por imagem , Adulto , Coração/diagnóstico por imagem , Humanos , Técnicas In Vitro , Miocárdio , Músculos Psoas/diagnóstico por imagem , Trombose/diagnóstico por imagem
11.
Acta Radiol ; 50(7): 709-15, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19701821

RESUMO

BACKGROUND: A thorough understanding of magnetic resonance (MR) contrast media dynamics makes it possible to choose the optimal contrast media for each investigation. Differences in visualizing hepatobiliary function between Gd-BOPTA and Gd-EOB-DTPA have previously been demonstrated, but less has been published regarding differences in liver vessel visualization. PURPOSE: To compare the liver vessel and liver parenchymal enhancement dynamics of Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist). MATERIAL AND METHODS: The signal intensity of the liver parenchyma, the common hepatic artery, the middle hepatic vein, and a segmental branch of the right portal vein was obtained in 10 healthy volunteers before contrast media administration, during arterial and portal venous phases, and 10, 20, 30, 40, and 130 min after intravenous contrast medium injection, but, due to scanner limitations, not during the hepatic venous phase. The doses of contrast media were 0.1 mmol/kg for Gd-BOPTA and 0.025 mmol/kg for Gd-EOB-DTPA. RESULTS: Maximum enhancement of liver parenchyma was observed from the portal venous phase until 130 min after Gd-BOPTA administration and from 10 min to 40 min after Gd-EOB-DTPA. There was no difference in maximum enhancement of liver parenchyma between the two contrast media. When using Gd-BOPTA, the vascular contrast enhancement was still apparent 40 min after injection, but had vanished 10 min after Gd-EOB-DTPA injection. The maximum difference in signal intensity between the vessels and the liver parenchyma was significantly greater with Gd-BOPTA than with Gd-EOB-DTPA (P<0.0001). CONCLUSION: At the dosage used in this study, Gd-BOPTA yields higher maximum enhancement of the hepatic artery, portal vein, and middle hepatic vein during the arterial and the portal venous phase and during the delayed phases than Gd-EOB-DTPA does, whereas there is no difference in liver parenchymal enhancement between the two contrast agents.


Assuntos
Gadolínio DTPA , Circulação Hepática , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Análise de Variância , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Funções Verossimilhança , Masculino , Meglumina/administração & dosagem , Compostos Organometálicos/administração & dosagem
12.
Acta Radiol ; 48(7): 755-62, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17729007

RESUMO

BACKGROUND: Borrelia infections, especially chronic neuroborreliosis (NB), may cause considerable diagnostic problems. This diagnosis is based on symptoms and findings in the cerebrospinal fluid but is not always conclusive. PURPOSE: To evaluate brain magnetic resonance imaging (MRI) in chronic NB, to compare the findings with healthy controls, and to correlate MRI findings with disease duration. MATERIAL AND METHODS: Sixteen well-characterized patients with chronic NB and 16 matched controls were examined in a 1.5T scanner with a standard head coil. T1- (with and without gadolinium), T2-, and diffusion-weighted imaging plus fluid-attenuated inversion recovery (FLAIR) imaging were used. RESULTS: White matter lesions and lesions in the basal ganglia were seen in 12 patients and 10 controls (no significant difference). Subependymal lesions were detected in patients down to the age of 25 and in the controls down to the age of 43. The number of lesions was correlated to age both in patients (rho = 0.83, P<0.01) and in controls (rho = 0.61, P<0.05), but not to the duration of disease. Most lesions were detected with FLAIR, but many also with T2-weighted imaging. CONCLUSION: A number of MRI findings were detected in patients with chronic NB, although the findings were unspecific when compared with matched controls and did not correlate with disease duration. However, subependymal lesions may constitute a potential finding in chronic NB.


Assuntos
Encefalopatias/patologia , Neuroborreliose de Lyme/patologia , Imageamento por Ressonância Magnética , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Encefalopatias/complicações , Encefalopatias/microbiologia , Estudos de Casos e Controles , Doença Crônica , Feminino , Humanos , Neuroborreliose de Lyme/complicações , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
13.
Acta Radiol ; 48(4): 362-8, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17453513

RESUMO

PURPOSE: To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance) and Gd-EOB-DTPA (Primovist) in normal healthy subjects. MATERIAL AND METHODS: Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences between the common hepatic duct (CHD) and liver parenchyma were measured before and 10, 20, 30, 40, 130, 240, and 300 min after contrast medium injection. RESULTS: Biliary enhancement was obvious 10 min post-injection for Gd-EOB-DTPA and was noted at 20 min for Gd-BOPTA. At 40 min delay, Gd-BOPTA reached its peak biliary enhancement, but at neither 30 nor 40 min delay was there any significant difference compared with that of Gd-EOB-DTPA. At later delays, the contrast between CHD and liver continued to increase for Gd-EOB-DTPA, whereas it decreased for Gd-BOPTA. CONCLUSION: The earlier onset and longer duration of a high contrast between CHD and liver for Gd-EOB-DTPA facilitates examination of hepatobiliary excretion. Therefore, Gd-EOB-DTPA may provide adequate hepatobiliary imaging within a shorter time span than Gd-BOPTA and facilitate scheduling at the MR unit. Further studies in patients are required to compare the imaging advantages of Gd-EOB-DTPA and Gd-BOPTA in clinical practice.


Assuntos
Ductos Biliares/anatomia & histologia , Meios de Contraste , Gadolínio DTPA , Gadolínio , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Ductos Biliares Intra-Hepáticos/anatomia & histologia , Meios de Contraste/administração & dosagem , Feminino , Gadolínio/administração & dosagem , Gadolínio DTPA/administração & dosagem , Ducto Hepático Comum/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Injeções Intravenosas , Fígado/anatomia & histologia , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Fatores de Tempo
14.
Acta Radiol ; 47(2): 172-8, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16604964

RESUMO

PURPOSE: To compare three methods for standardizing volume rendering technique (VRT) protocols by studying aortic diameter measurements in magnetic resonance angiography (MRA) datasets. MATERIAL AND METHODS: Datasets from 20 patients previously examined with gadolinium-enhanced MRA and with digital subtraction angiography (DSA) for abdominal aortic aneurysm were retrospectively evaluated by three independent readers. The MRA datasets were viewed using VRT with three different standardized transfer functions: the percentile method (Pc-VRT), the maximum-likelihood method (ML-VRT), and the partial range histogram method (PRH-VRT). The aortic diameters obtained with these three methods were compared with freely chosen VRT parameters (F-VRT) and with maximum intensity projection (MIP) concerning inter-reader variability and agreement with the reference method DSA. RESULTS: F-VRT parameters and PRH-VRT gave significantly higher diameter values than DSA, whereas Pc-VRT gave significantly lower values than DSA. The highest interobserver variability was found for F-VRT parameters and MIP, and the lowest for Pc-VRT and PRH-VRT. All standardized VRT methods were significantly superior to both MIP and F-VRT in this respect. The agreement with DSA was best for PRH-VRT, which was the only method with a mean error below 1 mm and which also had the narrowest limits of agreement (95% of cases between 2.1 mm below and 3.1 mm above DSA). CONCLUSION: All the standardized VRT methods compare favorably with MIP and VRT with freely selected parameters as regards interobserver variability. The partial range histogram method, although systematically overestimating vessel diameters, gives results closest to those of DSA.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Angiografia por Ressonância Magnética/normas , Análise de Variância , Angiografia Digital , Meios de Contraste , Gadolínio DTPA , Humanos , Imageamento Tridimensional , Variações Dependentes do Observador , Estudos Retrospectivos
15.
BMC Med Imaging ; 6: 1, 2006 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-16630362

RESUMO

BACKGROUND: Computed Tomography Cholangiography (CTC) is a fast and widely available alternative technique to visualise hepatobiliary disease in patients with an inconclusive ultrasound when MRI cannot be performed. The method has previously been relatively unknown and sparsely used, due to concerns about adverse reactions and about image quality in patients with impaired hepatic function and thus reduced contrast excretion. In this retrospective study, the feasibility and the frequency of adverse reactions of CTC when using a drip infusion scheme based on bilirubin levels were evaluated. METHODS: The medical records of patients who had undergone upper abdominal spiral CT with subsequent three-dimensional rendering of the biliary tract by means of CTC during seven years were retrospectively reviewed regarding serum bilirubin concentration, adverse reaction and presence of visible contrast media in the bile ducts at CT examination. In total, 153 consecutive examinations in 142 patients were reviewed. RESULTS: Contrast media was observed in the bile ducts at 144 examinations. In 110 examinations, the infusion time had been recorded in the medical records. Among these, 42 examinations had an elevated bilirubin value (>19 micromol/L). There were nine patients without contrast excretion; 3 of which had a normal bilirubin value and 6 had an elevated value (25-133 micromol/L). Two of the 153 examinations were inconclusive. One subject (0.7%) experienced a minor adverse reaction - a pricking sensation in the face. No other adverse effects were noted. CONCLUSION: We conclude that drip infusion CTC with an infusion rate of the biliary contrast agent iotroxate governed by the serum bilirubin value is a feasible and safe alternative to MRC in patients with and without impaired biliary excretion. In this retrospective study the feasibility and the frequency of adverse reactions when using a drip infusion scheme based on bilirubin levels has been evaluated.

16.
Br J Radiol ; 78(936): 1078-85, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16352582

RESUMO

The purpose of this study was to evaluate the diagnostic potential of prolonged drip infusion CT cholangiography (DIC-CT) using meglumine iotroxate (Biliscopin) and 3D volume rendering in patients with suspected obstructive biliary disease. From a material of 142 patients who had undergone a drip infusion CT, all cases with a verified surgical or endoscopic retrograde cholangiography (ERC) diagnosis (n=33) were selected. Age-matched controls were selected from the remaining examinations. Three radiologists reviewed all 66 examinations in retrospect, independently as well as in consensus. The image quality and the estimated diagnostic quality were rated as good or moderate in 91% of the 198 reviews. The consensus sensitivity and specificity for diagnosing biliary stones was 88% and 94%, respectively (with sensitivities ranging from 88% to 94% for individual observers, and specificities from 86% to 96%). Two out of three strictures were observed. No false positive strictures were described. The use of volume rendering technique (VRT) improved diagnostic certainty in 28/198 (14%) of the evaluations. The visualization of ductal stones was improved in 18/48 (38%). No differences in diagnostic quality between single and multislice CT were observed. We conclude that a detailed image of the biliary tree with good sensitivity and specificity can be obtained by means of bilirubin-governed infusion time DIC-CT with volume rendering reconstruction.


Assuntos
Cálculos Biliares/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Bilirrubina/sangue , Colangiografia/métodos , Colangiopancreatografia Retrógrada Endoscópica , Meios de Contraste , Feminino , Cálculos Biliares/patologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional/métodos , Infusões Intravenosas , Iodopamida/administração & dosagem , Iodopamida/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
17.
Acta Radiol ; 46(7): 671-8, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16372685

RESUMO

PURPOSE: To compare two commercially available computed tomography (CT) colonography systems with respect to interobserver variability, the influence of level of expertise, and the gradual reduction of reviewing time for each system. MATERIAL AND METHODS: Two residents and two radiologists using Siemens CTAPP Colography software and Viatronix V3D-Colon software reviewed supine and prone CT acquisitions from 24 patients in a primary 3D endoluminal view. The observers graded each case with respect to technical quality and diagnostic value, assessed the presence of pathology, and indicated the time spent on the viewing. RESULTS: Significant differences were found in technical quality (P < 0.001) and diagnostic value (P<0.001) depending on which system was used, with higher scores for the Viatronix software. The agreement between specialists tended to be higher than that between residents (kappa=0.63 (0.30-0.95) vs. kappa=0.51 (0.21-0.81)), and the residents gave significantly (P < 0.001) higher scores of technical quality. However, the level of expertise had no significant impact on the assessments. We noted extensive variability in pathological lesions found by the different observers. The number of findings did not differ between workstations, but the viewers tended to report larger polyp sizes with the Viatronix software. The time needed for viewing decreased significantly from the first to the last examination viewed by each observer. CONCLUSION: Both the evaluated systems present trustworthy images of the human colon, but in a primary 3D setting the Viatronix software is favored owing to the user-friendly interface, higher experienced technical quality, and better diagnostic value.


Assuntos
Colonografia Tomográfica Computadorizada/normas , Adulto , Idoso , Competência Clínica , Pólipos do Colo/patologia , Colonografia Tomográfica Computadorizada/instrumentação , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Fatores de Tempo
18.
Acta Radiol ; 46(5): 497-504, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16224925

RESUMO

PURPOSE: To propose a technique for standardizing volume-rendering technique (VRT) protocols and to compare this with maximum intensity projection (MIP) in regard to image quality and diagnostic confidence in stenosis diagnosis with magnetic resonance angiography (MRA). MATERIAL AND METHODS: Twenty patients were examined with MRA under suspicion of renal artery stenosis. Using the histogram function in the volume-rendering software, the 95th and 99th percentiles of the 3D data set were identified and used to define the VRT transfer function. Two radiologists assessed the stenosis pathology and image quality from rotational sequences of MIP and VRT images. RESULTS: Good overall agreement (mean kappa=0.72) was found between MIP and VRT diagnoses. The agreement between MIP and VRT was considerably better than that between observers (mean kappa=0.43). One of the observers judged VRT images as having higher image quality than MIP images. CONCLUSION: Presenting renal MRA images with VRT gave results in good agreement with MIP. With VRT protocols defined from the histogram of the image, the lack of an absolute gray scale in MRI need not be a major problem.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio DTPA , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Obstrução da Artéria Renal/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
19.
J Cardiovasc Magn Reson ; 6(3): 675-84, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15347132

RESUMO

The need for a quantitative method to assess atherosclerosis in vivo is well known. This study tested, in a familiar animal model of atherosclerosis, a combination of magnetic resonance imaging (MRI) and image processing. Six spontaneously hyperlipidemic (Watanabe) rabbits were examined with a knee coil in a 1.5-T clinical MRI scanner. Inflow angio (2DI) and proton density weighted (PDW) images were acquired to examine 10 cm of the aorta immediately cranial to the aortic bifurcation. Examination of the thoracic aorta was added in four animals. To identify the inner and outer boundary of the arterial wall, a dynamic contour algorithm (Gradient Vector Flow snakes) was applied to the 2DI and PDW images, respectively, after which the vessel wall area was calculated. The results were compared with histopathological measurements of intima and intima-media cross-sectional area. The correlation coefficient between wall area measurements with MRI snakes and intima-media area was 0.879 when computed individual-wise for abdominal aortas, 0.958 for thoracic aortas, and 0.834 when computed segment-wise. When the algorithm was applied to the PDW images only, somewhat lower correlations were obtained. The MRI yielded significantly higher values than histopathology, which excludes the adventitia. Magnetic resonance imaging, in combination with dynamic contours, may be a suitable technique for quantitative assessment of atherosclerosis in vivo. Using two sequences for the measurement seems to be superior to using a single sequence.


Assuntos
Doença da Artéria Coronariana/patologia , Hiperlipidemias/patologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Algoritmos , Animais , Aorta Abdominal/patologia , Aorta Torácica/patologia , Vasos Coronários/patologia , Modelos Animais , Coelhos , Túnica Íntima/patologia
20.
Acta Radiol ; 45(4): 453-9, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15323400

RESUMO

PURPOSE: To compare the volume rendering technique (VRT) with maximum intensity projection (MIP) for aortic diameter measurements in MR angiography (MRA) data sets. MATERIAL AND METHODS: Existing contrast-enhanced 3-dimensional MRA and digital subtraction angiography (DSA) data sets from 20 patients were analyzed. In each MRA data set, two aortic diameters were measured using MIP and VRT. Agreement with DSA measurements, dependence on rendering parameters, and interobserver agreement were assessed. RESULTS: Diameters measured on MIP with fixed parameters showed no significant difference compared with DSA and with freely selected parameters a slight overestimation relative to DSA. Diameters measured on VRT were larger than on DSA. For both MIP and VRT, the measurements depended on the chosen parameters. The error relative to DSA was larger for VRT than for MIP with fixed parameters but not with freely chosen parameters. Interobserver agreement did not differ significantly. CONCLUSIONS: VRT is not suitable for diameter measurements of the abdominal aorta with fixed parameter settings but may be useful with user-selected settings.


Assuntos
Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/patologia , Angiografia por Ressonância Magnética , Idoso , Análise de Variância , Angiografia Digital/estatística & dados numéricos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Artéria Renal/diagnóstico por imagem , Artéria Renal/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...