1.
Perfusion ; 11(6): 471-80, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8971949

RESUMO

Oxygenation performance was tested in 15 membrane oxygenators by calculating the resistance for oxygenation (R) and the calculation of oxygen transferred versus FiO2. The clinical data reveal that the SARNS Turbo 440 (36.7-51.9%), the AFFINITY (37.2-50.1%) and the HF 5400 (37.5-52.3%) are the oxygenators with the lowest FiO2 settings for comparable amounts of oxygen transferred during hypothermia and during normothermia followed by MAXIMA Plus (39.1-55.8%), MAXIMA Plus PRF (39.1-56.2%), CAPIOX SX 18 (39.7-61.2%), MONOLYTH (43.0-61.3%), OXIM 11-34 (44.1-63.9%), COBE Duo (44.7-64.9%), COBE Optima (47.4-66.4%), COMPACTFLO (48.3-65.3%), SAFE II (49.0-67.6%), UNIVOX (49.8-71.3%), MAXIMA (50.2-70.1%) and the CM 50 (58.6-77.0%). Similar results were found by calculation of R. HF 5400 (2.41-1.87 mmHg/min/ml O2), AFFINITY (2.63-1.87 mmHg/min/ml O2). OXIM II-34 (2.72-2.45 mmHg/min/ml O2), MAXIMA Plus PRF (2.75-2.07 mmHg/min/ ml O2), COBE Optima (2.83-2.13 mmHg/min/ml O2), UNIVOX (2.84-2.17 mmHg/min/ml O2), MONOLYTH (2.89-2.24 mmHg/min/ml O2), SARNS Turbo 440 (3.03-2.12 mmHg/min/ml O2), MAXIMA Plus (3.09-2.28 mmHg/min/ml O2), SAFE 11 (3.19-2.50 mmHg/min/ml O2), CAPIOX SX 18 (3.27-2.44 mmHg/ min/ml O2), COMPACTFLO (3.41-2.50 mmHg/min/ml O2), MAXIMA (3.53-2.72 mmHg/min/ml O2), COBE Duo (3.57-2.71 mmHg/min/ml O2) and the CM 50 (3.53-2.72 mmHg/min/ml O2). As a measure of controllability of oxygenation, the coefficient of variation on the FiO2 ordered on the normothermic blood samples was used, giving as a result CAPIOX SX 18 (2.9-2.5%), AFFINITY (3.6-3.5%), COBE Duo (4.3-2.9%), HF 5400 (5.7-4.7%), MAXIMA Plus (8.1-5.4%), COMPACTFLO (8.2-5.0%), MONOLYTH (8.3-4.0%), MAXIMA (8.7-3.4%), COBE Optima (9.6-6.8%), SARNS Turbo 440 (10.1-7.3%), MAXIMA Plus PRF (10.9-8.7%), CM 50 (11.9-2.4%), UNIVOX (13.3-8.9%), OXIM 11-34 (15.5-17.3%) and the SAFE II (16.1-9.8%). The low FiO2 settings and the lower resistance for oxygenation are an indication of the reserve capacity of the oxygenators whose importance is proven by clinical data of emergency perfusions on patients under full resuscitation.


Assuntos
Ponte Cardiopulmonar/instrumentação , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenadores de Membrana/normas , Idoso , Estudos de Avaliação como Assunto , Humanos , Hipertermia Induzida , Pessoa de Meia-Idade
2.
Acta Chir Belg ; 76(6): 563-6, 1977.
Artigo em Francês | MEDLINE | ID: mdl-596090

RESUMO

Benign chondroma of the thyroid cartilage is a rare condition with a good prognosis if surgical treatment is radical. After presenting a personal case the authors briefly review the literature (Acta chir. belg., 1977, 76, 563-566.


Assuntos
Condroma/patologia , Cartilagens Laríngeas , Neoplasias Laríngeas/patologia , Adulto , Condroma/cirurgia , Humanos , Neoplasias Laríngeas/cirurgia , Masculino