Pacing Clin Electrophysiol ; 37(5): 569-75, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24359248

RESUMO

INTRODUCTION: Prior studies have suggested that pacemaker reuse may be a reasonable alternative to provide device therapy in the low- and middle-income countries. We studied explant indications and remaining battery life of cardiac implantable electronic devices (CIEDs) at a tertiary medical center. METHODS AND RESULTS: We conducted a retrospective review of all CIEDs extracted at the University of Michigan between 2007 and 2011. Devices were considered reusable if battery longevity was ≥48 months or >75% battery life was remaining; there was no evidence of electrical malfunction, and they were not under advisory or recall. Eight hundred and one CIEDs were explanted: Medtronic (MDT [Medtronic Inc., Minneapolis, MN, USA]; 454), Boston Scientific (BS [Boston Scientific Corp., Natick, MA, USA])/Guidant (GDT; 255 [Guidant Corp., St. Paul, MN, USA]), St. Jude Medical (SJM; 73 [St. Paul, MN, USA]), and Biotronik (BTK; 15 [Biotronik GmBH, Berlin, Germany]). After eliminating devices explanted for elective replacement indicator (ERI, 541), 51.9% of pacemakers (41/79), 54.2% of implantable cardioverter-defibrillators (ICDs) (64/118), and 47.6% of cardiac resynchronization therapy and defibrillation (CRT-D) devices (30/63) had sufficient battery life and no evidence of electrical malfunction to be considered for reuse. A logistic regression analysis found that the indications for device removal independently predicted reusability: upgrade to an ICD (odds ratio [OR] 162.8, P < 0.001) or CRT-D (OR 63.8, P < 0.001), infection (OR 110.7, P < 0.001), heart transplantation or left ventricular assist device placement (OR 56.6, P < 0.001), and device removal at patient's request (OR 115.4, P < 0.001). CONCLUSION: The majority of explanted CIEDs for reasons other than ERI have an adequate battery life and, if proven safe, may conceivably be reutilized for basic pacing in underserved nations where access to this life-saving therapy is limited.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Fontes de Energia Elétrica/estatística & dados numéricos , Análise de Falha de Equipamento/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Reutilização de Equipamento/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Feminino , Humanos , Masculino , Michigan , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Atenção Terciária/estatística & dados numéricos , Revisão da Utilização de Recursos de Saúde
2.
Am J Med ; 126(10): 903-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23932159

RESUMO

OBJECTIVE: This study aimed to measure the impact of a school-based multidisciplinary intervention program on risk factors for atherosclerosis in sixth-grade middle school students. We also measured health behaviors before and after the intervention using a validated questionnaire. METHODS: A prospective study was performed in which students served as historical controls. Sixth-grade students from 23 middle schools in 12 cities with varying populations were exposed to a program promoting healthful activity and nutrition habits through educational and environmental change. Along with a modified School-Based Nutrition Monitoring behavioral questionnaire, physiologic risk factors were studied, including body mass index, systolic and diastolic blood pressures, cholesterol panel, and random blood glucose, which were measured before the 10-week program and again 1 to 3 months after program completion. RESULTS: Of 4021 sixth graders (male, 49%) at 23 middle schools completing a before and after behavioral survey, 2118 students, aged 11.56 ± 0.47 years, consented to participate in the screening. The mean total cholesterol value decreased from 161.64 ± 28.99 mg/dL to 154.77 ± 27.26 mg/dL (P < .001). The low-density lipoprotein value decreased from 89.37 ± 25.08 mg/dL to 87.14 ± 24.25 mg/dL (P < .001). The high-density lipoprotein value decreased from 52.15 ± 13.35 md/dL to 49.95 ± 13.28 mg/dL (P < .001). The measure of triglycerides decreased from 113.34 ± 73.19 mg/dL to 101.22 ± 63.93 mg/dL (P < .001). The random glucose value decreased from 97.51 ± 16.00 to 94.94 ± 16.62 (P < .001). The mean systolic blood pressure decreased from 109.47 ± 15.26 mm Hg to 107.76 ± 10.87 mm Hg (P < .001), and the mean diastolic blood pressure decreased from 64.78 ± 8.57 mm Hg to 63.35 ± 7.81 mm Hg (P < .001). These changes in physiologic measures seemed to correlate with self-reported increases in vegetable and fruit consumption, increases in physical activity, and less screen time. CONCLUSIONS: Project Healthy Schools, a middle school intervention to improve childhood cardiovascular risk factors, is feasible and seems to be effective. The results showed significant improvements in risk factors associated with early atherosclerosis among sixth-grade students, including total cholesterol, low-density lipoprotein cholesterol, triglycerides, and systolic and diastolic blood pressures. Further study with a larger group of students and a longer follow-up period would be valuable.


Assuntos
Glicemia/análise , Pressão Sanguínea , Doenças Cardiovasculares/prevenção & controle , Comportamentos Relacionados com a Saúde , Promoção da Saúde/métodos , Lipídeos/sangue , Adolescente , Criança , Exercício Físico , Feminino , Humanos , Masculino , Michigan , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Fatores de Risco , Instituições Acadêmicas