Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
J Knee Surg ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38552644

RESUMO

Cementless implant use continues to increase primarily due to increased numbers of younger and obese patients opting for primary total knee arthroplasty (TKA). Given the increased use of cementless implants, the purpose of this study was to evaluate the midterm clinical performance of cementless TKA using a highly porous tibial baseplate compared with its cemented counterpart of the same system. We conducted a retrospective case-control study of 400 patients undergoing primary TKA that included 200 patients with cementless components matched for age and body mass index (BMI) to 200 patients with cemented implants of the same implant design with a 5-year follow-up. We evaluated clinical results, complications, revisions, and overall survivorship between the cohorts. Statistical analysis was performed using student t-test and chi-square analysis. There was no statistical difference in age (64.3 vs. 64.3 p = 0.81), BMI (34 vs. 33.1 p = 0.19), preoperative Knee Society Score (KSS) function (41 vs. 32.3 p = 0.22), and preoperative KSS knee score (39.2 vs. 38.3 p = 0.54) between the cementless and cemented cohorts, respectively. The cementless group had seven revisions, while the cemented group had nine revisions (p = 0.609). The cementless group had one revision due to aseptic loosening versus five in the cemented group (p = 0.09). Postoperative 5-year KSS knee scores were 92.84 versus 91.75 (p = 0.386) and function scores were 81.81 versus 69.65 (p = 0.00004) in the cementless and cemented groups, respectively. The cementless group had survivorship of 96.5% for all-cause revision compared with 95.5% in the cemented group at 5-year follow-up (p = 0.60). Cementless TKA using a highly porous tibial baseplate showed excellent midterm results with one case of aseptic loosening at 5-year follow-up and with similar Knee Society outcome scores and survivorship compared with the cemented group. Cementless TKA demonstrated noninferiority to cemented TKA and could be used as an alternative mode of fixation in patients opting for primary TKA. Additional long-term follow-up is needed to determine if cementless TKA can demonstrate improved survivorship over cemented TKA.

2.
J Arthroplasty ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38401620

RESUMO

BACKGROUND: Psychotropic medications are commonly used to treat several mental health conditions. The aim of this study was to determine the impact of psychotropic medications in patients undergoing primary total knee arthroplasty (TKA) with respect to postoperative opioid use, complications, patient-reported outcome measures, and satisfaction. METHODS: This is a retrospective cohort study of 514 consecutive patients undergoing primary TKA. There were 120 patients (23.3%) who were excluded due to preoperative opioid usage. The remaining 394 patients had a minimum 1-year follow-up. Of those, 133 (34%) were on psychotropic medications preoperatively and were compared to the remaining 261 (66%) patients who were not on psychotropics. Clinical data, satisfaction, Knee Society (KS) scores, Western Ontario McMaster Universities Arthritis Index, Patient-Reported Outcomes Measurement Index Score, Forgotten Joint Scores, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, postoperative opioid medication usage, and complications were compared. RESULTS: The study cohort (psychotropic medications) had significantly lower postoperative KS Function, KS Knee, Forgotten Joint Scores, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Western Ontario McMaster Universities Arthritis Index, and Patient-Reported Outcomes Measurement Index Score compared to the control group. The study group had a lower overall satisfaction score (Likert scale 1 to 5) and a lower percentage of patients either satisfied or very satisfied (4.55 versus 4.79, P < .001; 92.0 versus 97.24%, P = .03, respectively). Postoperative opioid usage was significantly greater in the study group at both 6.4 weeks (range, 4 to 8) and 12-month follow-up (52.76 versus 13.33%, P < .001; 5.51 versus 0.39%, P = .002, respectively). There were no differences in complications and revisions between the groups. CONCLUSIONS: Patients on psychotropic medications should be educated on the risk of increased opioid consumption, diminished satisfaction, and patient-reported outcome measures following primary TKA. Given the large number of patients on psychotropic medications undergoing TKA, additional studies are needed to further improve clinical outcomes in this group.

3.
J Knee Surg ; 37(4): 267-274, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37040872

RESUMO

Initial design cementless metal-backed patellar implants failed due to multiple reasons including implant design, use of first-generation polyethylene, and surgical technique. This study evaluates clinical outcomes and survivorship of total knee arthroplasty (TKA) using a current generation highly porous metal-backed patellar component. One-hundred twenty-five consecutive primary cementless TKAs with a compression molded highly porous metal-backed patella were reviewed. One-hundred three TKAs (82.4%) with 5-year clinical and radiographic follow-up were available for review. These were matched with 103 consecutive TKAs using a cemented patella of the same implant design. The cementless cohort had a mean age of 65.5 years, body mass index (BMI) of 33.0, and follow-up of 64.4 months. Indications for cementless TKA were based on multiple factors including age, BMI, and bone quality. There were no revisions for loosening or mechanical failure of the cementless patella compared with two cemented patellae revised for aseptic loosening. Eight patients required revisions in the cementless cohort: three for prosthetic joint infection (PJI), two for instability, one periprosthetic femur fracture, one for patella instability, and one for extensor mechanism rupture. Five patients required revisions in the cemented cohort: two for aseptic patellar loosening, one for aseptic femoral loosening, one for PJI, and one for instability. All-cause survivorship at 5 years was 92.2 and 95.1% for the cementless metal-backed implant and cemented implant cohorts, respectively. Use of a compression molded highly porous metal-backed patella component demonstrated excellent clinical and radiographic results at 5-year follow-up. Longer follow-up is required to evaluate the ability of highly porous cementless patella implants to provide durable long-term fixation.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Idoso , Patela/diagnóstico por imagem , Patela/cirurgia , Seguimentos , Porosidade , Artroplastia do Joelho/métodos , Metais , Reoperação , Desenho de Prótese , Resultado do Tratamento , Falha de Prótese
4.
Bone Joint J ; 105-B(12): 1279-1285, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38035601

RESUMO

Aims: The use of cementless total knee arthroplasty (TKA) components has increased during the past decade. The initial design of cementless metal-backed patellar components had shown high failure rates due to many factors. The aim of this study was to evaluate the clinical results of a second-generation cementless, metal-backed patellar component of a modern design. Methods: This was a retrospective review of 707 primary TKAs in 590 patients from a single institution, using a cementless, metal-backed patellar component with a mean follow-up of 6.9 years (2 to 12). A total of 409 TKAs were performed in 338 females and 298 TKAs in 252 males. The mean age of the patients was 63 years (34 to 87) and their mean BMI was 34.3 kg/m2 (18.8 to 64.5). The patients were chosen to undergo a cementless procedure based on age and preoperative radiological and intraoperative bone quality. Outcome was assessed using the Knee Society knee and function scores and range of motion (ROM), complications, and revisions. Results: A total of 24 TKAs (3.4%) in 24 patients failed and required revision surgery, of which five were due to patellar complications (0.71%): one for aseptic patellar loosening (0.14%) and four for polyethylene dissociation (0.57%). A total of 19 revisions (2.7%) were undertaken in 19 patients for indications which did not relate to the patella: four for aseptic tibial loosening (0.57%), one for aseptic femoral loosening (0.14%), nine for periprosthetic infection (1.3%), one for popliteus impingement (0.14%), and four for instability (0.57%). Knee Society knee and function scores, and ROM, improved significantly when comparing pre- and postoperative values. Survival of the metal-backed patellar component for all-cause failure was 97.5% (95% confidence interval 94.9% to 100%) at 12 years. Conclusion: The second-generation cementless TKA design of metal-backed patellar components showed a 97.5% survival at 12 years, with polyethylene dissociation from the metal-backing being the most common cause of patellar failure. In view of the increased use of TKA, especially in younger, more active, or obese patients, these findings are encouraging at mean follow-up of seven years.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Patela/cirurgia , Desenho de Prótese , Reoperação , Metais , Polietileno , Falha de Prótese , Seguimentos , Resultado do Tratamento
5.
Arthroplast Today ; 22: 101169, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37521737

RESUMO

Background: Patient satisfaction and patient-reported outcome measures (PROMs) are important for patients, surgeons, and payers in the current healthcare climate. Morbidly obese patients (body mass index [BMI] >40) have demonstrated higher incidence of complications after total knee arthroplasty (TKA) and can have difficulty obtaining access for their surgical care. The purpose of this study was to evaluate PROMs and patient satisfaction in morbidly obese patients undergoing primary TKA. Methods: A total of 75 patients with BMI >40 kg/m2 undergoing robotic-assisted TKA were retrospectively identified and matched 2:1 to a consecutive cohort of patients with BMI <35. The average BMI of the study cohort was 42.4 kg/m2 (39.5-51.3) compared to 28.6 kg/m2 (18.5-34.9) in the control group. Clinical outcomes, PROMs, and patient satisfaction were evaluated at a minimum 2-year follow-up. Results: The patients of the BMI >40 cohort were less likely to be discharged home (P = .0076), had less active flexion at 2 years (P = .0046), and had worse knee scores at 2 years (0.0497). Despite this, the percentage of patients who were satisfied or very satisfied after surgery was similar between the groups (87.5% vs 91.2%, P = .1943). Conclusions: Morbidly obese patients are less likely to be discharged directly to home and may have functional differences after primary TKA. However, morbidly obese patients have similar PROMs and are as satisfied as nonobese patients at 2 years. Morbidly obese patients with end-stage knee osteoarthritis should also be able to enjoy the benefits of primary TKA following medical and surgical optimization.

6.
J Arthroplasty ; 38(6S): S137-S144, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36791887

RESUMO

BACKGROUND: Historically, 1st generation metal-backed cementless patellar implants demonstrated high failure rates due to multiple factors. The 2nd generation cementless implants were developed with purported improvements in component design and polyethylene wear characteristics. This study evaluated clinical results of a current generation cementless metal-backed patellar implant with a minimum 5-year follow-up. METHODS: One hundred and thirty-six primary total knee arthroplasties (TKAs) with metal-backed cementless patellae were compared to 183 cemented patellae with the same implant design. The cementless group mean age was 61 years (range, 40 to 81), mean body mass index (BMI) of 34.9 (range, 22.6 to 64.5), and mean follow-up of 10 years (range, 5 to 13). The cemented group mean age was 65 years (range, 32 to 89), mean BMI of 32.5 (range, 18.2 to 56.6), and mean follow-up of 10 years (range, 5 to 12). Significant demographic differences of age (P < .001), BMI (P < .01), and sex (P < .001) were found, with cementless patients being younger, heavier, and with more men. RESULTS: There were no statistical differences in non-revision procedures (P = .214), TKA revisions (P = .639), patellar revisions (P = .151), and patellar aseptic loosening (P = .737). The 10-year survivorship of the cementless metal-backed patella was 95.9% with all-cause failure as the endpoint. The 10-year survivorship of the cemented patellar component was 98.9%. CONCLUSION: This study demonstrated noninferiority of a 2nd generation HA-coated cementless metal-backed patellar implant in primary TKA compared to cemented patellae with 10-year survivorship of 95.9%. Advances in implant design and polyethylene wear properties have led to improved clinical results with metal-backed patellar components in primary TKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Patela , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Seguimentos , Metais , Patela/cirurgia , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
7.
J Knee Surg ; 36(9): 995-1000, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35679852

RESUMO

Morbidly obese patients undergoing cemented primary total knee arthroplasty (TKA) can pose a challenging problem with implant survivorship due to greater stress at the cement-bone interface. With the advent of additive manufacturing (three-dimensional printing), highly porous implants are now readily available. The purpose of this study was to review the results of primary TKA in the morbidly obese (body mass index [BMI] ≥ 40) patient using a highly porous cementless tibial baseplate. This is a retrospective study of 167 TKAs in patients with morbid obesity undergoing primary cementless TKA with a minimum 5-year follow-up. A total of 6 patients died and 14 were lost to follow-up, leaving 147 TKAs in 136 patients with a mean follow-up of 66 months (range 60-79 months). The average age was 59 years (range 36-84 years) and average BMI was 45 kg/m2 (range 39.5-63.9). Clinical results, patient-reported outcome measures, radiographs, and complications were reviewed. There were 9 failures requiring revision, including 3 for aseptic tibial loosening (2.0%), 2 for deep infection (1.4%), 2 for patellar resurfacing (1.4%), 1 for patella instability (0.7%), and 1 for extensor mechanism rupture (0.7%). Knee Society Score (KSS) improved from 48 to 90 at 2- and 5-year follow-up. KSS function score improved from 49 to 68 and 79 at 2- and 5-year follow-up, respectively. Survivorship with aseptic loosening as the endpoint was 98.0% at 5 years. Cementless TKA using a highly porous tibial baseplate in morbidly obese patients demonstrated excellent clinical results with 98% survivorship at 5 years and appears to offer durable long-term biologic fixation as an alternative to mechanical cement fixation in this challenging group of patients.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Obesidade Mórbida , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Seguimentos , Porosidade , Reoperação , Desenho de Prótese , Cimentos Ósseos , Falha de Prótese , Resultado do Tratamento
8.
Orthopedics ; 46(2): e111-e117, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36476288

RESUMO

Highly cross-linked polyethylene (HXLPE) has become the preferred bearing surface in total hip arthroplasty. However, its acceptance in total knee arthroplasty (TKA) has not been as robust because of concerns pertaining to wear and its impact on implant failure. Therefore, this multicenter study was purposed to evaluate the 10-year (1) radiographic outcomes; (2) complications; and (3) implant survivorship in patients with TKA receiving a sequentially irradiated and annealed HXLPE. A retrospective, multi-center study was performed on 139 patients (171 TKAs) who underwent primary TKA with HXLPE and possessed a minimum of 10-year follow-up. Radiographs were analyzed for radiolucencies along the implant-fixation interface using the Modern Knee Society Radiographic Evaluation System. Kaplan-Meier analysis determined implant survivorship when the end points were revision for polyethylene wear and polyethylene revision for any reason. Sixteen TKAs (9.9%) demonstrated periprosthetic linear radio-lucencies. Seventeen TKAs (9.9%) required additional surgeries, 9 (5.3%) of which were revisions, with 1 (0.6%) TKA requiring revision because of polyethylene wear. Other causes of revision included instability (1.8%), infection (1.6%), and arthrofibrosis (1.6%). The mean time to revision was 5.9 years (range, 0.1-11.1 years). Survivorship pertaining to polyethylene revision for wear was 99.4%, whereas all-cause polyethylene revision was 94.7%. This study in patients undergoing primary TKA using a second-generation HXLPE demonstrated excellent results with respect to polyethylene wear characteristics and strength with a 99.4% survivorship at 10 years. [Orthopedics. 2023;46(2):e111-e117.].


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Polietileno , Estudos Retrospectivos , Seguimentos , Falha de Prótese , Desenho de Prótese , Reoperação
9.
J Arthroplasty ; 38(3): 567-572.e1, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36191695

RESUMO

BACKGROUND: Stiffness following total knee arthroplasty (TKA) is a disabling complication and manipulation under anesthesia (MUA) is often performed as an early intervention. Few studies have focused on the revision risk, infection risk, demographics, and clinical outcomes in Medicare patients undergoing MUA following primary TKA. METHODS: We reviewed 142,440 patients who had primary TKA from a national database and identified 3,652 patients (2.6%) who underwent MUA. Patient demographics and comorbid conditions were evaluated to identify risk factors. Incidence of revision and periprosthetic joint infection (PJI) at 1-, 2-, and 5-year time points in a cohort of MUA patients was compared to patients who did not undergo MUA. Multivariate Cox regressions were used for statistical analyses. RESULTS: The incidence of MUA was higher in Black versus White individuals (4.1 versus 2.5%, P < .001). Revision risk was significantly greater in the MUA group at 1-, 2-, and 5-year time points with a hazard ratio (HR) of, 3.81, 3.90, and 3.22 respectively, P < .001. One- and 2-year revision risk was significantly greater when MUA occurred at 6 to 12 months post-TKA when compared to <3 months, P < .05. Risk of PJI was significantly greater in the MUA group with a HR of 2.2, 2.2, and 2.1 at 1, 2, and 5 years, respectively P < .001. CONCLUSION: The incidence of MUA was 2.6%. There was an increased incidence of revision surgery and PJI in patients undergoing MUA. Patients at increased risk for stiffness following TKA should be closely monitored and treated with early intervention to minimize risk of poor outcomes.


Assuntos
Artrite Infecciosa , Artroplastia do Joelho , Humanos , Idoso , Estados Unidos , Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Medicare , Fatores de Risco , Incidência , Artrite Infecciosa/etiologia , Estudos Retrospectivos , Reoperação
10.
J Knee Surg ; 36(13): 1374-1379, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36116441

RESUMO

Chronic opioid use prior to total knee arthroplasty (TKA) has been implicated in adverse outcomes. The purpose of this study was to evaluate clinical outcome measures and patient satisfaction in patients with a history of preoperative chronic opioid use undergoing primary TKA. A retrospective cohort study was performed on 296 consecutive patients undergoing primary TKA. Seventy-four (25%) patients were identified with chronic preoperative opioid use (study group; 22 males, 52 females). A 3:1 matched cohort ratio of control versus study group was utilized resulting in a control group consisting of 222 patients (97 males, 125 females) without chronic opioid use prior to surgery. There was no statistically significant difference in age, BMI, or follow-up. Average follow-up was 23.4 months in the control group and 23.6 months in the study group (p = 0.87). Clinical data including patient satisfaction (Likert score), Knee Society (KS) Knee scores, KS Function scores, Forgotten Joint Score (FJS), length of stay (LOS), and complications were evaluated. Patient satisfaction at the most recent visit was 92.8% in the control group versus 83.8% in the chronic opioid group (p = 0.0016). Differences in patient-reported outcomes measures comparing the control and study cohorts included KS Function Score of 83.23 versus 75.31 (p = 0.0034). The FJS of 63.7 versus 58 (p = 0.1883) and the KS Knee Score of 89.5 versus 88.1 (p = 0.4075) were not significant. Postoperative opioid usage for the control versus the study group was 62/222 (27.9%) versus 56/74 (75.7%) at 4 to 8 weeks (p <0.0001), and 4/222 (1.80%) versus 27/74 (36.5%) at 12 months (p <0.0001). Overall complication occurrence was 18.9% in the study group versus 11.3% in the control group (p = 0.11). Patients with history of chronic preoperative opioid use had significantly lower patient satisfaction and KS Function scores and increased postoperative opioid usage at 12 months compared with patients without a history of opioid use prior to TKA.


Assuntos
Artroplastia do Joelho , Transtornos Relacionados ao Uso de Opioides , Osteoartrite do Joelho , Masculino , Feminino , Humanos , Artroplastia do Joelho/efeitos adversos , Satisfação do Paciente , Analgésicos Opioides/uso terapêutico , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento
11.
J Arthroplasty ; 38(3): 484-490, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36122689

RESUMO

BACKGROUND: Alternative alignment concepts have garnered great interest in an effort to improve patient satisfaction following primary total knee arthroplasty (TKA). The purpose of this study is to determine variation or deviation from an individual's native joint line in primary TKA using neutral mechanical versus a restricted kinematic technique. METHODS: An institutional review board-approved prospective cohort study was performed evaluating the effect of neutral mechanical alignment (nMA) versus a restricted kinematic alignment (rKA) on the native joint line in 100 consecutive patients undergoing primary TKA. Using preoperative computed tomography and intraoperative 3-dimensional software, 2 virtual preoperative plans were created: nMA and rKA. Templated bone resections were recorded. Change in joint line was calculated using known implant planar thickness and planned bone resection. RESULTS: nMA yielded significantly greater deviation from the patient's native joint line along the lateral compartment of the knee (lateral distal femoral condyle, lateral posterior femoral condyle, lateral tibial resection). With nMA, the lateral distal femoral joint line was distalized by a mean 4.3 versus 2.6 mm using rKA technique (P < .001). In rKA, >60% of knees had <3 mm of deviation from the native lateral posterior femoral offset, whereas in nMA, >95% of knees had ≥3 mm change in the lateral posterior femoral condylar offset. CONCLUSION: nMA-TKA resulted in statistically larger joint line deviations compared to rKA-TKA, most notably along the lateral distal femoral condyle joint line. Further analysis is needed to determine the clinical consequences of joint line deviation from the native anatomy using nMA as the target for primary TKA.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Prospectivos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Fenômenos Biomecânicos
12.
J Arthroplasty ; 37(7S): S588-S591, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35276279

RESUMO

BACKGROUND: Large femoral head sizes are commonly used in total hip arthroplasty (THA) to minimize the risk of instability. With small acetabular cup-size, large femoral head diameter often results in the use of thin polyethylene liners. The purpose of this study was to evaluate clinical and radiographic results of large femoral heads against thin polyethylene liners with minimum 5-year follow-up. METHODS: This was a retrospective review identifying 58 primary THAs utilizing thin polyethylene inserts from one manufacturer (X3 polyethylene, Stryker, Mahwah, NJ) and large femoral heads (36 mm or greater) with minimum 5-year follow-up. A total of 3 patients were deceased and 11 lost to follow-up, leaving 44 patients for review. All patients were female with mean age 65.7 (range 26-85) and mean body mass index (BMI) 29.9 (range 19.6-45.4). Average length of follow-up was 8.5 years (range 5.1-11.3). Outcome measures included survivorship, complications, PROMs and radiographic analysis. RESULTS: There were four revisions: two aseptic loosening, one prosthetic joint infection, and one recurrent dislocation. Average HOOS-Jr, FJS-12, and patient satisfaction using Likert score was 94.3/100, 92.9/100, and 4.69/5.00, respectively, with 94% of patients reporting being satisfied or very satisfied. Radiographic analysis at average of 8.5 years demonstrated well-fixed implants without evidence of progressive radiolucent lines, osteolysis, or failure of the polyethylene liner. Survivorship using failure of the thin polyethylene liner as the endpoint was 100% at an average of 8.5 years. CONCLUSION: Thin polyethylene liners used with large femoral head sizes in small acetabular cups demonstrated excellent results at average 8.5-year follow-up with no cases of liner fracture or osteolysis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Cabeça do Fêmur/cirurgia , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Osteólise/etiologia , Polietileno , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos
13.
J Robot Surg ; 16(5): 1209-1217, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34997477

RESUMO

The purpose of this study was to determine if significant clinical differences exist in patient-reported outcome measures (PROMs) between PS and CR TKAs implanted using robotic-assisted technology. This was an IRB-approved retrospective study from an institutional database evaluating 214 knees in 190 patients. Inclusion criteria included: primary RA-TKA, age 22-89 at the time of surgery, preoperative coronal limb deformity within 15º of neutral alignment, and minimum 1-year follow-up. The PS cohort consisted of 103 patients with 107 RA-TKAs, whereas the CR cohort consisted of 87 patients with 107 RA-TKAs. Cohorts were compared on the basis of demographics and PROMs (KSS knee, KSS function, FJS-12, KOOS-JR, WOMAC, and 5-point satisfaction Likert scale) collected preoperatively and at 1-year follow-up. Statistical analyses comparing measures were conducted via Student's t tests for continuous data and Chi-squared analyses for categorical data. There were no significant differences identified in short-term PROMs at 1-year follow-up between cohorts (all p values > 0.05). 93.1% of patients with CR knees and 94.7% of patients with PS knees reported a satisfaction level of "very satisfied" or "satisfied". Revision arthroplasty occurred in six knees (2.8%, 3 knees in CR cohort, 3 knees in PS cohort) with no differences in overall complications between groups. The use of RA-TKA technology promoted high patient satisfaction scores within this study, independent of CR or PS implant type with no significant differences in PROMs, satisfaction, revisions, or complications between the two groups.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Procedimentos Cirúrgicos Robóticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Adulto Jovem
14.
Arthroplast Today ; 11: 140-145, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34541267

RESUMO

BACKGROUND: There is a paucity of data on the long-term performance of highly cross-linked polyethylene (HXLPE). Therefore, this study evaluated 10-year 1) functional, 2) radiographic, and 3) surgical outcomes in patients who underwent total hip arthroplasty with sequentially irradiated and annealed HXLPE. METHODS: A retrospective, multicenter study was conducted on patients who underwent primary total hip arthroplasty and received HXLPE polymer (n = 151). Two-dimensional radiographic linear and volumetric wear analyses were quantified using the Martell Hip Analysis software, while functional outcomes were assessed by analyzing postoperative Short-Form-12 (SF-12) Physical and Mental Health Surveys and Harris Hip Scores. Radiographic outcomes included yearly linear (mm/y) and volumetric (mm3/y) wear rates. Surgical outcomes included additional operations and survivorship. RESULTS: SF-12 scores were within 1 standard deviation (SD) of the normal population (SF-12 Physical: 47.0; SF-12 Mental: 52.0), while the Harris Hip Scores of 89.5 was borderline between "good" and "excellent." Total and annual linear wear rates were 0.164 mm (SD: 0.199 mm) and 0.015 mm/y (SD: 0.018 mm/y), respectively. The mean total volumetric wear rate was 141.4 mm3 (SD: 165.0) and 12.6 mm3/y (SD: 14.9 mm3/y) when broken down into a yearly rate. Eleven patients required revisions, resulting in an all-cause polyethylene survivorship of 92.7%, with a polyethylene wear survivorship of 100.0%. CONCLUSIONS: Our results demonstrate clinically undetectable linear and volumetric wear rates after 10 years in those who received the unique sequentially irradiated and annealed HXLPE. Furthermore, high rates of survivorship coupled with low all-cause revision rates illustrate the polymers' capability to potentially increase implant longevity.

15.
Bone Joint J ; 103-B(6 Supple A): 59-66, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34053299

RESUMO

AIMS: Alternative alignment concepts, including kinematic and restricted kinematic, have been introduced to help improve clinical outcomes following total knee arthroplasty (TKA). The purpose of this study was to evaluate the clinical results, along with patient satisfaction, following TKA using the concept of restricted kinematic alignment. METHODS: A total of 121 consecutive TKAs performed between 11 February 2018 to 11 June 2019 with preoperative varus deformity were reviewed at minimum one-year follow-up. Three knees were excluded due to severe preoperative varus deformity greater than 15°, and a further three due to requiring revision surgery, leaving 109 patients and 115 knees to undergo primary TKA using the concept of restricted kinematic alignment with advanced technology. Patients were stratified into three groups based on the preoperative limb varus deformity: Group A with 1° to 5° varus (43 knees); Group B between 6° and 10° varus (56 knees); and Group C with varus greater than 10° (16 knees). This study group was compared with a matched cohort of 115 TKAs and 115 patients using a neutral mechanical alignment target with manual instruments performed from 24 October 2016 to 14 January 2019. RESULTS: Mean overall patient satisfaction for the entire cohort was 4.7 (SE 0.1) on a 5-point Likert scale, with 93% being either very satisfied or satisfied compared with a Likert of 4.3 and patient satisfaction of 81% in the mechanical alignment group (p < 0.001 and p < 0.006 respectively). At mean follow-up of 17 months (11 to 27), the mean overall Likert, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, Western Ontario and McMaster Universities Osteoarthritis Index, Forgotten Joint Score, and Knee Society Knee and Function Scores were significantly better in the kinematic group than in the neutral mechanical alignment group. The most common complication in both groups was contracture requiring manipulation under anaesthesia, involving seven knees (6.1%) in the kinematic group and nine knees (7.8%) in the mechanical alignment group. CONCLUSION: With the advent of advanced technology, and the ability to obtain accurate bone cuts, the target limb alignment, and soft-tissue balance within millimetres, using a restricted kinematic alignment concept demonstrated excellent patient satisfaction following primary TKA. Longer-term analysis is required as to the durability of this method. Cite this article: Bone Joint J 2021;103-B(6 Supple A):59-66.


Assuntos
Artroplastia do Joelho/métodos , Genu Varum/cirurgia , Satisfação do Paciente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos
16.
J Arthroplasty ; 36(7): 2331-2334, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33602588

RESUMO

BACKGROUND: Tourniquet use is common in total knee arthroplasty (TKA), but debate exists regarding its use and effect on patient outcomes. The study purpose was to compare the effect of short tourniquet (ST) time vs long tourniquet (LT) time on pain, opioid consumption, and patient outcomes. METHODS: Patients were prospectively randomized to an ST time of 10 min vs LT time. A total of 100 consecutive patients undergoing primary cementless robotic-assisted TKA underwent randomization, with 5 patients unable to complete follow-up, leaving 49 in the ST group and 46 in the LT cohort. Visual analog scale pain scores, morphine equivalent, serum creatine kinase, distance walked, range of motion, length of stay (LOS), surgical time, hemoglobin (Hgb), and Knee Society Scores (KSS) were prospectively collected. RESULTS: Visual analog scale pain was statistically equivalent at 24, 48, and 72 hours and at 2 and 6 weeks postoperatively. Morphine equivalent consumption was 36 vs 44 (P = .03), 48 vs 50 (P = .72), 31 vs 28 (P = .57), and 4.7 vs 5.5 (P = .75) in the LT vs ST cohorts at 24 hours, 48 hours, 2weeks, and 6weeks postoperatively. Change in Hgb postoperative day 1 was 2.7 in both groups (P = .975). Postoperative day 1 creatine kinase-MB was 3.7 and 3.0 (P = .30) in LT and ST cohorts. Six-week postoperative KSS Knee and Function scores were 82.4 and 70.5 in LT group vs 80.8 and 72.3 in ST group (P = .61 and P = .63). Postoperative range of motion, LOS, and surgical time were equivalent. CONCLUSION: This study demonstrates no significant advantage of ST use in primary TKA with respect to opioid consumption, patient-reported pain, KSS scores, LOS, or postoperative Hgb level.


Assuntos
Artroplastia do Joelho , Artroplastia do Joelho/efeitos adversos , Perda Sanguínea Cirúrgica , Humanos , Articulação do Joelho/cirurgia , Dor Pós-Operatória/epidemiologia , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Amplitude de Movimento Articular , Torniquetes , Resultado do Tratamento
17.
J Knee Surg ; 34(7): 730-738, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31731324

RESUMO

Approximately 20% of the patients are dissatisfied with their total knee arthroplasty (TKA). Computer technology has been introduced for TKA to provide real time intraoperative information on limb alignment and exact flexion/extension gap measurements. The purpose of this study was to determine if patient satisfaction could be improved with the use of robotic-assisted (RA) technology following primary TKA. A total of 120 consecutive patients undergoing RA-TKA with real time intraoperative alignment and gap balancing information were compared with a prospective cohort of 103 consecutive patients undergoing TKA with manual jig-based instruments during the same time period. There were no differences between groups with age, gender, baseline Knee Society Score (KSS) knee and function scores, follow-up, and ASA scores. TKAs were performed using same technique, implant design, anesthesia, and postoperative treatment protocols. Patient satisfaction survey using KSS and Likert scoring system were obtained at 1-year follow-up. Likert scoring system demonstrated 94% of the patients in the RA group were either very satisfied or satisfied versus 82% in the manual instruments TKA group (p = 0.005). RA-TKA group had better average scores of all five satisfaction questions although not significant. RA-TKA group had a better average overall satisfaction score of 7.1 versus 6.6 in the manual instrument group, p = 0.03. KSS function scores were significantly better at 6 weeks and 1 year postoperatively (p = 0.02, 0.005), and KSS knee scores were significantly better at 1 year postoperatively (p = 0.046). There are multiple reasons for patient dissatisfaction following primary TKA. Using intraoperative computer technology with RA surgery for patients undergoing a primary TKA, a significant improvement in patient satisfaction was demonstrated compared with TKA using conventional manual jig-based instruments. RA surgery provides several advantages in TKA including real time information in millimeters to help obtain balanced gaps, accurate bone cuts, reduced soft tissue injury, and achieve the target alignment which may lead to improved patient satisfaction.


Assuntos
Artroplastia do Joelho/métodos , Satisfação do Paciente , Procedimentos Cirúrgicos Robóticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Joelho/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Lesões dos Tecidos Moles/cirurgia
18.
J Knee Surg ; 34(7): 705-711, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31683348

RESUMO

Peripheral nerve blocks such as a femoral + sciatic block have demonstrated significant pain relief following TKA. However, these nerve blocks have residual motor deficits which prevent immediate postoperative ambulation. The purpose of this study was to compare outcomes in patients undergoing primary TKA with femoral and sciatic (Fem + Sci) motor nerve blocks versus an adductor canal and the interspace between the popliteal artery and the capsule of the posterior knee and adductor canal block (IPACK + ACB) sensory nerve blocks. A total of 100 consecutive patients were reviewed, 50 received Fem + Sci nerve blocks and 50 received IPACK + ACB blocks preoperatively. There were no differences in the two groups with respect to surgical technique, implant type, postoperative pain, and physical therapy protocols. Differences in opioid requirements, length of stay (LOS), distance walked, and common knee scoring systems were analyzed. Among them, 62% IPACK + ACB patients were discharged on postoperative day 1 compared with 14% in the Fem + Sci group (p < 0.0001). The IPACK + ACB patients had a shorter LOS (mean 1.48 days vs. 2.02 days, p < 0.001), ambulated further on postoperative day 0 (mean 21.4 feet vs. 5.3 feet, p < 0.001), and required less narcotics the day after surgery (mean, 15.7 vs. 24.0 morphine equivalents p < 0.0001) and at 2 weeks (mean, 6.2 vs. 9.3 morphine equivalents, p = 0.025). The use of this combination IPACK and ACB demonstrated improved early ambulation with a decrease in opioid use and length of stay compared with a femoral and sciatic motor nerve block in patients undergoing primary TKA.


Assuntos
Analgésicos Opioides , Artroplastia do Joelho/efeitos adversos , Tempo de Internação , Idoso , Idoso de 80 Anos ou mais , Anestésicos Locais , Feminino , Nervo Femoral/cirurgia , Humanos , Joelho/cirurgia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Morfina , Bloqueio Nervoso/métodos , Manejo da Dor , Dor Pós-Operatória/etiologia , Alta do Paciente , Artéria Poplítea
19.
J Arthroplasty ; 35(8): 2097-2100, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32402579

RESUMO

BACKGROUND: Obese and morbidly obese patients undergoing primary total knee arthroplasty (TKA) place significant stress at the bone-cement-implant interface over the life of the patient. The purpose of this study is to evaluate results of cemented, posterior-stabilized TKA in obese and morbidly obese patients at an average follow-up of 10 years. METHODS: Retrospective study of 181 patients who had a cemented, posterior-stabilized TKA between 2000 and 2013 with body mass index >35 at the time of surgery was conducted. Clinical data and radiographs were evaluated along with survivorship, complications, and revisions. Minimum follow-up was 5 years with an average follow-up of 10 years. RESULTS: There were 135 women and 46 men in the study, with mean age of 60.2 years (range 43-80), mean body mass index of 42.0 (range 35.1-66.1), and an average follow-up of 10 years (range 5-18). There were a total of 39 failures (22%) that underwent revision TKA surgery with mean time to revision of 8 years. Failures included 25 (14%) cases of aseptic loosening; 9 (5%) polyethylene wear; 2 (1%) prosthetic joint infection; and 3 additional revisions for instability, pain, and stiffness. There were a total of 11 cases of isolated tibial component loosening and 13 for both tibial and femoral loosening. Survivorship at 15 years with aseptic loosening as the endpoint was 86.7%, and for all causes 79.6% at 15 years. CONCLUSION: Aseptic loosening is the leading cause of failure following TKA in obese and morbidly obese patients with decreasing survivorship from 96.1% to 91.2% and 86.7% at 5, 10, and 15 years, respectively.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Obesidade Mórbida , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação , Estudos Retrospectivos
20.
Surg Technol Int ; 36: 399-403, 2020 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32243564

RESUMO

INTRODUCTION: Proximally coated, morphometric wedge femoral stems illustrated excellent survivorship and clinical outcomes at a minimum five-year postoperative follow up. MATERIALS AND METHODS: We completed a retrospective review of 186 THA patients from three high-volume surgeons to assess clinical- and patient-reported outcomes five years after implantation with a cementless, proximally coated morphometric wedge femoral stem. We reviewed Gruen zones on early postoperative and mid-term radiographs for signs of osteolysis, loosening, and wear. Clinical- and patient-reported outcomes were compared with previously published two-year outcomes for these femoral stems. RESULTS: No progression of radiolucencies or loosening was observed radiographically when comparing minimum one-year and five-year follow up. Reactive radiodense lines were observed in 23 cases (12.64%), and 13 cases (7.14%) exhibited true radiolucencies of 1-3mm, and all remained unchanged between follow ups or were no longer present on the five-year film. Cortical hypertrophy was noted in Gruen zones 3 and/or 5 in 11 cases (6.04%). No stems were revised for mechanical loosening or for periprosthetic fracture. Nine (9) patients (4.87%) underwent revisions during the follow-up period for periprosthetic infection, femoral head and/or acetabular component revisions, and impingement requiring release and femoral head change. Average Harris Hip Scores were excellent at five years and improved slightly when compared to a two-year follow up; however, this change was not statistically significant. Health-related quality of life mental component and physical component scores were a mean of 48.45 and 43.10 at 5 years, respectively. All cause Kaplan-Meier survivorship of the femoral stem was calculated at 98.4% at an average 65.7 months post implantation. Additionally, this cohort exhibited 100% aseptic survivorship during the follow-up period. CONCLUSION: Newer-generation morphometric wedge femoral stems for THA exhibit excellent radiographic stability, patient satisfaction, and clinical outcomes five years post implantation.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Desenho de Prótese , Falha de Prótese , Qualidade de Vida , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...