Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 44(4): 1545-1551, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28094855

RESUMO

PURPOSE: In this work, we develop a methodology for using Fricke gel dosimeters for dose distribution measurements surrounding high-density implants which circumvents artifact production by removing the obstruction during imaging. METHODS: Custom 3D printed molds were used to set cavities in Fricke gel phantoms to allow for the suspension of high-density implants in different geometries. This allowed for the metal valve extracted from a temporary tissue expander to be suspended during irradiation, and removed during optical-CT scanning. RESULTS: The removal of the metal implant and subsequent backfilling of the remaining cavity with optically matched fluid prior to dose evaluation enables accurate optical-CT scanning of the gel dosimeters. Results have shown very good agreement between measured and calculated doses within 2 mm from the surface of the implant. Slight deviations are present within 1 mm of the interface. CONCLUSIONS: Artifacts in the form of radial streaking, cold spots, and hot spots were all reduced using this technique, enabling the broader and more accurate use of optical-CT for the imaging of gels containing opaque objects.


Assuntos
Próteses e Implantes , Dosímetros de Radiação , Artefatos , Géis , Fenômenos Ópticos , Imagens de Fantasmas , Impressão Tridimensional , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...