Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Neurosci ; 90: 199-205, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34275549

RESUMO

OBJECTIVE: To evaluate the safety and efficacy of the low-profile Acandis Acclino microstent for embolization of recurrent and residual intracranial aneurysms. METHODS: Consecutive patients treated with the Acclino for aneurysm remnants at three German neurovascular centers were enrolled. The technical success, complications, angiographic and clinical outcome were investigated. RESULTS: Nineteen patients (median age: 53 years) with 19 aneurysm remnants (median size: 5 mm, anterior circulation: 14) were included. Initial aneurysm treatment consisted of stand-alone coiling in 14 cases, stent-assisted coiling in 4 and clipping in 1. Acclino stent-assisted coil embolization was performed technically successfully in all patients. Morbidity occurred in one patient (5.3%) due to aneurysm perforation. At the angiographic follow-up with a median follow-up duration of 21 months (range: 5-37 months), complete occlusion was obtained in 76.9%. The retreatment rate was 7.7%. CONCLUSIONS: Retreatment of aneurysm remnants with the Acclino microstent was associated with high aneurysm occlusion rates and acceptable morbidity. Further studies will be necessary to draw a definite conclusion.


Assuntos
Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Retratamento , Estudos Retrospectivos , Resultado do Tratamento
2.
Clin Neuroradiol ; 31(1): 107-115, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31970465

RESUMO

PURPOSE: Low-profile intracranial stents are characterized by a miniaturized design that enables deployment via a 0.0165″ or 0.017″ internal diameter microcatheter, which is typically intended for coil delivery. This study analyzed the incidence, clinical relevance and risk factors of thromboembolic events (TEE) occurring during low-profile stent-assisted coiling of intracranial aneurysms. METHODS: This was a retrospective, multicenter analysis of consecutive patients who underwent stent-assisted aneurysm coiling (SAC) with the laser-cut Acandis Acclino and Neuroform Atlas stents. The study evaluated the incidence of symptomatic and asymptomatic TEEs and the impact on functional outcome. Risk factors for TEEs were determined by univariate and bivariate logistic regression analyses. RESULTS: Among 131 procedures (mean patient age 56.5 ± 12.8 years, mean aneurysm size: 6.7 ± 3.9 mm) TEEs occurred in 14 cases (10.7%) of which 2 patients (1.5%) developed ischemic stroke, while the remaining TEEs remained asymptomatic. Multivariate analysis revealed Y­stenting as potential risk factor for TEEs (odds ratio: 3.9, 95% confidence interval: 1.0-16.5; p = 0.08). CONCLUSION: The use of SAC with low-profile intracranial stents is associated with a favorable safety profile; however, Y­stenting may carry an increased risk of TEEs, which needs to be considered during treatment planning.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Angiografia Cerebral , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Incidência , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/epidemiologia , Aneurisma Intracraniano/terapia , Lasers , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...