1.
J Am Chem Soc ; 131(6): 2078-9, 2009 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-19161257

RESUMO

The atypical 1:2 complexation between an electron-rich crown ether host and electron-deficient naphthalene diimide-based guests led to the formation of alternative donor-acceptor (ADA) stacks. The ADA stacks can be expediently obtained in high yield as polycrystalline aggregates from solution. More remarkably, the high degree of organization has also been realized in a simple solid-to-solid mechanical grinding process. The solid-state structures have been verified by solid-state NMR spectroscopy, single crystal, and powder X-ray diffraction analysis. The current findings not only provide convenient ways of obtaining novel donor-acceptor stacks involving a macrocyclic host but also represent an important step in transferring electroactive host-guest systems from solution to the solid state.

2.
Anal Chem ; 79(13): 5097-102, 2007 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-17530818

RESUMO

A generic method for the rapid, reproducible, and robust bonding of microfluidic chips fabricated from plastics has been developed and optimized. One of the bonding surfaces is exposed to solvent vapor prior to bringing the mating parts into contact and applying a load. Nanoindentation measurements performed by atomic force microscopy show that a reversible material softening occurs upon exposure to solvent vapor. Subsequent exposure of the bonded chip to UV light then strengthens the bond between mating parts and increases the burst pressure by 50% due to partial cross-linking and chain scission reactions as measured by size exclusion chromatography-multiangle light scattering (SEC-MALS). Performing all steps of this procedure at room temperature eliminates channel distortion observed during thermal bonding and affords channels with highly uniform cross-sectional dimensions. Our technique enables chips resistant to pressures as high as 34.6 MPa.


Assuntos
Teste de Materiais , Microfluídica/métodos , Plásticos/química , Reagentes de Ligações Cruzadas/química , Gases , Microfluídica/instrumentação , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Pressão , Solventes/química , Propriedades de Superfície , Temperatura , Fatores de Tempo , Raios Ultravioleta
3.
Anal Chem ; 78(14): 4969-75, 2006 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-16841919

RESUMO

With the use of the copper(I)-catalyzed (3 + 2) azide-alkyne cycloaddition, an element of "click chemistry," stationary phases carrying long alkyl chains or soybean trypsin inhibitor have been prepared for use in HPLC separations in the reversed-phase and affinity modes, respectively. The ligands were attached via a triazole ring to size monodisperse porous beads containing either alkyne or azide pendant functionalities. Alkyne-containing beads prepared by direct copolymerization of propargyl acrylate with ethylene dimethacrylate were allowed to react with azidooctadecane to give a reversed-phase sorbent. Azide-functionalized beads were prepared by chemical modification of glycidyl methacrylate particles. Subsequent reaction with a terminal aliphatic alkyne produced a reversed-phase sorbent similar to that obtained from the alkyne beads. Soybean trypsin inhibitor was functionalized with N-(4-pentynoyloxy)succinimide to carry alkyne groups and then allowed to react with the azide-containing beads to produce an affinity sorbent for trypsin. The performance of these stationary phases was demonstrated with the HPLC separations of a variety of peptides and proteins.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Peptídeos/química , Polímeros/química , Proteínas/química , Alcinos/química , Azidas/química , Interações Hidrofóbicas e Hidrofílicas , Modelos Moleculares , Estrutura Molecular , Estrutura Terciária de Proteína , Proteínas/metabolismo , Tripsina/metabolismo
4.
J Sep Sci ; 28(16): 2094-103, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16318205

RESUMO

LC of polymers under limiting conditions of adsorption (LC LCA) is a novel method based on different mobility of (pore excluded) macromolecules compared to (pore permeating) solvent molecules. Polymer sample is injected in a solvent preventing its adsorption within the column. Eluent promotes sample adsorption. Under these conditions, macromolecules cannot leave its initial solvent and elute from the column independently of their molar mass. In contrast, a less interactive simultaneously injected polymer leaves its initial solvent zone and is eluted in the size exclusion mode. As a result, chemically different polymer species can be discriminated. The effect of selected experimental conditions was studied on the LC LCA behavior of poly(methyl methacrylate)s eluted from bare silica gel columns. The parameters were packing pore diameter, injected sample volume and concentration, as well as column temperature. The size independent elution was only little affected by the above parameters and LC LCA produced well-focused peaks. The LC LCA mechanism was operative even at a very large sample of both volume and concentration. This makes LC LCA a robust and user-friendly method, likely suitable also for characterization of minor components of polymer mixtures.


Assuntos
Cromatografia Líquida/métodos , Polímeros/isolamento & purificação , Adsorção , Cromatografia Líquida/instrumentação , Temperatura
5.
J Chromatogr A ; 1094(1-2): 42-8, 2005 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-16257287

RESUMO

Liquid chromatography under limiting conditions of desorption (LC LCD) is a method which allows molar mass independent elution of various synthetic polymers. A narrow, slowly moving zone of small molecules, which promotes full adsorption of one kind of polymer species within column (an adsorli) acts as an impermeable barrier for the fast moving macromolecules. The latter accumulate on the barrier edge and elute nearly in total volume of liquid within column. At the same time, transport of less adsorptive macromolecules is not hampered so that these are eluted in the size exclusion (SEC) mode. As result, polymers differing in their polarity and adsorptivity can be easily separated without molar mass interference. Three methods of barrier creation are discussed and compared. It is shown that a fraction of sample may elute unretained if the adsorli sample solvent is used as a barrier in connection with a narrow-pore column packing. One part of excluded macromolecules likely breaks-out from the adsorli zone and this results in partial loss of sample and distortion of the LC LCD peaks. This problem can be avoided if the adsorli zone is injected immediately before sample solution. Applicability of the LC LCD method for polymer separation has been demonstrated with a model mixture of poly(methyl methacrylate) (adsorbing polymer) and polystyrene (non adsorbing polymer) using bare silica gel as a column packing with a combination of tetrahydrofuran (a desorption promoting liquid -a desorli) and toluene (adsorli). It has been shown that the LC LCD procedure with tandem injection allows simple and fast discrimination of polymer blend components with good repeatability and high sample recovery. For quantitative determination of molar masses of both LC LCD and SEC eluted polymers, an additional size exclusion chromatographic column can be applied either in a conventional way or in combination with a multi-angle light scattering detector. A single eluent is used in the latter column, which separates the mixed mobile phase, system peaks and the desorli zone from the polymer peaks so that measurements are free from disturbances caused by the changing eluent composition. The resulting LC LCD x SEC procedure has been successfully applied to poly(methyl methacrylate) samples.


Assuntos
Cromatografia Líquida/métodos , Polímeros/isolamento & purificação , Peso Molecular , Espalhamento de Radiação , Soluções
6.
J Chromatogr A ; 1084(1-2): 173-9, 2005 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-16114251

RESUMO

The high performance liquid chromatography of polymers under limiting conditions of adsorption (LC LCA) separates macromolecules, either according to their chemical structure or physical architecture, while molar mass effect is suppressed. A polymer sample is injected into an adsorption-active column flushed with an adsorption promoting eluent. The sample solvent is a strong solvent which prevents sample adsorption. As a result, macromolecules of sample elute within the zone of their original solvent to be discriminated from other, non-adsorbing polymer species, which elute in the exclusion mode. LC LCA sample recovery has been studied in detail for poly (methyl methacrylate)s using a bare silica gel column and an eluent comprised toluene (adsorli) and tetrahydrofuran (desorli). Sample solvent was tetrahydrofuran. It was found that a large part of injected sample may be fully retained within the LC LCA columns. The amount of retained polymer increases with decreasing packing pore size and with higher sample molar masses and, likely, also with the column diameter. The extent of full retention of sample does not depend of sample volume. An additional portion of the injected desorli sample solvent (a tandem injection) does not fully eliminate full retention of the sample fraction and the reduced recovery associated with it. The injected sample is retained along the entire LC LCA column. The reduced sample recovery restricts applicability of many LC LCA systems to oligomers and to discrimination of the non-adsorbing minor macromolecular components of complex polymer mixtures from the adsorbing major component(s). The full retention of sample molecules within columns may also complicate the application of other liquid chromatographic methods, which combine entropic and enthalpic retention mechanisms for separation of macromolecules.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Polimetil Metacrilato/isolamento & purificação , Adsorção