Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Heart Valve Dis ; 5(6): 647-55, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8953443

RESUMO

BACKGROUND AND AIMS OF THE STUDY: No prior studies have defined pre- versus postoperative hemodynamics of large numbers of patients with low mean transvalvular gradients. This was our objective. METHODS: Retrospective analysis was undertaken of preoperative and postoperative echo/Doppler data in 294 patients who underwent aortic valve replacement (AVR) for aortic stenosis (AS). Some 136 patients had a preoperative mean gradient of < 50 mmHg. The relationship of preoperative to pre- minus postoperative (delta) mean gradient (GRAD), peak valvular velocity (V2), left ventricular outflow tract velocity (V1), V1/V2 ratio, V2-V1, and aortic valve area (AVA) were plotted and analyzed such that a 'zero-benefit threshold' from surgery could be estimated. RESULTS: Strong relationships (r > 0.80) were noted for GRAD to delta GRAD, V2 to delta V2, and (V2-V1) to delta (V2-V1) with zero-benefit thresholds of 16 mmHg for GRAD, 2.6 m/s for V2 and 1.7 m/s for V2-V1. These thresholds were lower in patients who received homografts (11 mmHg, 2.2 m/s, and 1.1 m/s respectively), p < 0.02. The relationship of pre operative V1/V2 to delta V1/V2 and AVA-delta AVA were weaker (r = 0.52 and 0.33 respectively) with zero-benefit thresholds of 0.41 and 2.0 cm2. Among patients with depressed preoperative fractional shortening, improvement was confined to those without coexistent coronary artery disease. CONCLUSION: This analysis of thresholds of mean gradient benefit suggests that most patients with low gradient AS improve hemodynamically from AVR. The hemodynamic 'break-even' point averages a mean gradient of 16 mmHg.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/transplante , Próteses Valvulares Cardíacas , Hemodinâmica , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Bioprótese , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Transplante Homólogo , Resultado do Tratamento , Ultrassonografia
2.
Ann Thorac Surg ; 46(4): 389-90, 1988 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3263092

RESUMO

"Redo" operations for coronary artery disease have become commonplace. One of the major complications that occurs is perioperative infarction due to embolization of atheromatous material from diseased veins into the distal coronary arteries. Because of this, we began using retrograde coronary sinus perfusion (RCSP) for delivery of cardioplegia to prevent the embolization of grumous material. It is our belief that retrograde flow through the coronary arteries is an effective preventive measure. In addition, RCSP is a simple method of delivery in redo operations such as aortic valve replacement where the majority of coronary flow is through patent vein grafts. Sixty-five of approximately 3,100 patients in our practice in the past three years underwent a cardiac operation in which RCSP was used for cardioplegia delivery. Ventricular function in all patients was well preserved, and all survived. There were no complications associated with the use of this method.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Soluções Cardioplégicas/administração & dosagem , Ponte de Artéria Coronária , Embolia/prevenção & controle , Feminino , Valvas Cardíacas/cirurgia , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Reoperação
5.
8.
Appl Microbiol ; 22(6): 1034-40, 1971 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-5137578

RESUMO

Heat treatment of highly purified staphylococcal enterotoxin B causes a more rapid loss of immunological activity at 70 to 80 C than at 90 to 100 C. Toxicological results based on intravenous injection of dogs paralleled the results obtained by immunological means (single gel diffusion). The loss of immunological activity did not follow first-order kinetics. Results are given on the effects on heat inactivation of changing pH, ionic strength, and initial concentration of enterotoxin. Disc-gel electrophoresis of purified enterotoxin B showed a major and minor band. The minor band was a size isomer of the major band.


Assuntos
Enterotoxinas/toxicidade , Temperatura Alta , Concentração de Íons de Hidrogênio , Staphylococcus , Animais , Soluções Tampão , Sistema Livre de Células , Cromatografia , Cães , Eletroforese Descontínua , Enterotoxinas/análise , Enterotoxinas/biossíntese , Enterotoxinas/isolamento & purificação , Enterotoxinas/metabolismo , Liofilização , Injeções Intravenosas , Fosfatos , Desnaturação Proteica , Sorotipagem , Staphylococcus/metabolismo , Vômito/induzido quimicamente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...