Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(6): 10679-10689, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38571273

RESUMO

We present the first mid-infrared optical frequency comb spectrometer employing an absorption cell based on self-fabricated, all-silica antiresonant hollow-core fiber (ARHCF). The spectrometer is capable of measuring sub-mL sample volumes with 26 m interaction length and noise equivalent absorption sensitivity of 8.3 × 10-8 cm-1 Hz-1/2 per spectral element in the range of 2900 cm-1 to 3100 cm-1. Compared to a commercially available multipass cell, the ARHCF offers a similar interaction length in a 1000 times lower gas sample volume and a 2.8 dB lower transmission loss, resulting in better absorption sensitivity. The broad transmission windows of ARHCFs, in combination with a tunable optical frequency comb, make them ideal for multispecies detection, while the prospect of measuring samples in small volumes makes them a competitive technique to photoacoustic spectroscopy along with the robustness and prospect of coiling the ARHCFs open doors for miniaturization and out-of-laboratory applications.

2.
Nat Commun ; 15(1): 161, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167498

RESUMO

Accurate parameters of molecular hot-band transitions, i.e., those starting from vibrationally excited levels, are needed to accurately model high-temperature spectra in astrophysics and combustion, yet laboratory spectra measured at high temperatures are often unresolved and difficult to assign. Optical-optical double-resonance (OODR) spectroscopy allows the measurement and assignment of individual hot-band transitions from selectively pumped energy levels without the need to heat the sample. However, previous demonstrations lacked either sufficient resolution, spectral coverage, absorption sensitivity, or frequency accuracy. Here we demonstrate OODR spectroscopy using a cavity-enhanced frequency comb probe that combines all these advantages. We detect and assign sub-Doppler transitions in the spectral range of the 3ν3 ← ν3 resonance of methane with frequency precision and sensitivity more than an order of magnitude better than before. This technique will provide high-accuracy data about excited states of a wide range of molecules that is urgently needed for theoretical modeling of high-temperature data and cannot be obtained using other methods.

3.
Opt Express ; 31(17): 27667-27676, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37710837

RESUMO

We characterized and analyzed the effect of intracavity spectral filtering in the Er:fiber laser mode-locked with a semiconductor saturable absorber mirror (SESAM). We studied the dispersive properties of bandpass filters and their influence on the characteristics of generated soliton pulses. Our analysis showed that various sideband structures were induced by the filter dispersion profiles and shaped through the interaction of the soliton with the dispersive wave. In addition, intracavity filtering improved the intensity and phase noise of the laser significantly, and we showed optimal filtering conditions for both types of noise. By adding a 10 nm bandpass filter to the laser resonator, the intensity and phase noise were improved 2- and 2.6 times, respectively.

4.
Biomed Opt Express ; 13(4): 1899-1911, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35519271

RESUMO

We report the development of a widely-tunable femtosecond fiber laser system and its application for two-photon vision studies. The source is based on an Er-doped fiber laser with spectral shift up to 2150 nm, followed by a second harmonic generation module to generate a frequency-doubled beam tunable from 872 to 1075 nm. The source delivers sub-230 fs pulses with nearly-constant duration over the entire tuning range, with output powers between 0.68-1.24 mW, which corresponds to a pulse energy of 13.2-24.1 pJ. Such pulse energy is sufficient for employing a system for measurements of two-photon scotopic spectral sensitivity of two-photon vision in humans. The laser parameters allow for very efficient and safe two-photon stimulation of the human visual system, as proved by a good separation between one- and two-photon thresholds for wavelengths below 950 nm, which we have confirmed for 3 healthy subjects.

5.
Sci Rep ; 12(1): 404, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013520

RESUMO

In this work, we show that the nonlinear evolution of femtosecond seed pulses with different parameters (temporal and spectral shapes, repetition rate, pulse energy) in an Yb-fiber amplifier leads to gain-managed nonlinear amplification, enabling robust generation of high-peak-power and nearly transform-limited pulses after external compression. We demonstrate a compressed pulse duration of 33 fs with an energy of 80.5 nJ and a peak power of 2.29 MW for a source with a repetition rate of 30 MHz. For a second seed source with a repetition rate of 125 MHz, we obtained a pulse duration of 51 fs with an energy of 22.8 nJ and a peak power of 420 kW. Numerical simulations incorporating rate equations and nonlinear propagation in the amplifier provide evolutions that agree well with the experimental results. The discrepancies in the amplifier's absorption edge appearing at low repetition rates and higher pump powers are attributed to the temperature dependence of the amplifier's gain cross-sections. Here, we experimentally verify this attribution and thus underline the importance of accounting for the fiber core temperature for precise modelling of the short-wavelength spectral edge of the output pulses in nonlinear Yb-fiber amplifiers. We also measure, for the first time, the relative intensity noise of an amplifier operating in the gain-managed nonlinear regime. The measurements reveal a significant contribution of the amplification process to the overall output noise of the system.

6.
J Clin Invest ; 132(2)2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34847075

RESUMO

BackgroundNoninvasive assessment of metabolic processes that sustain regeneration of human retinal visual pigments (visual cycle) is essential to improve ophthalmic diagnostics and to accelerate development of new treatments to counter retinal diseases. Fluorescent vitamin A derivatives, which are the chemical intermediates of these processes, are highly sensitive to UV light; thus, safe analyses of these processes in humans are currently beyond the reach of even the most modern ocular imaging modalities.MethodsWe present a compact, 2-photon-excited fluorescence scanning laser ophthalmoscope and spectrally resolved images of the human retina based on 2-photon excitation (TPE) with near-infrared light. A custom Er:fiber laser with integrated pulse selection, along with intelligent postprocessing of data, enables excitation with low laser power and precise measurement of weak signals.ResultsWe demonstrate spectrally resolved TPE fundus images of human subjects. Comparison of TPE data between human and mouse models of retinal diseases revealed similarity with mouse models that rapidly accumulate bisretinoid condensation products. Thus, visual cycle intermediates and toxic byproducts of this metabolic pathway can be measured and quantified by TPE imaging.ConclusionOur work establishes a TPE instrument and measurement method for noninvasive metabolic assessment of the human retina. This approach opens the possibility for monitoring eye diseases in the earliest stages before structural damage to the retina occurs.FundingNIH, Research to Prevent Blindness, Foundation for Polish Science, European Regional Development Fund, Polish National Agency for Academic Exchange, and Polish Ministry of Science and Higher Education.


Assuntos
Oftalmoscópios , Imagem Óptica , Retina , Doenças Retinianas , Animais , Modelos Animais de Doenças , Feminino , Humanos , Masculino , Camundongos , Camundongos Knockout , Pessoa de Meia-Idade , Retina/diagnóstico por imagem , Retina/metabolismo , Doenças Retinianas/diagnóstico por imagem , Doenças Retinianas/genética , Doenças Retinianas/metabolismo
7.
Opt Express ; 29(19): 30155-30167, 2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34614744

RESUMO

We present a new design of a robust cavity-enhanced frequency comb-based spectrometer operating under the continuous-filtering Vernier principle. The spectrometer is based on a compact femtosecond Er-doped fiber laser, a medium finesse cavity, a diffraction grating, a custom-made moving aperture, and two photodetectors. The new design removes the requirement for high-bandwidth active stabilization present in the previous implementations of the technique, and allows scan rates up to 100 Hz. We demonstrate the spectrometer performance over a wide spectral range by detecting CO2 around 1575 nm (1.7 THz bandwidth and 6 GHz resolution) and CH4 around 1650 nm (2.7 THz bandwidth and 13 GHz resolution). We achieve absorption sensitivity of 5 × 10-9 cm-1 Hz-1/2 at 1575 nm, and 1 × 10-7 cm-1 Hz-1/2 cm-1 at 1650 nm. We discuss the influence of the scanning speed above the adiabatic limit on the amplitude of the absorption signal.

8.
Opt Lett ; 46(15): 3677-3680, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34329254

RESUMO

Dual-comb (DC) ranging is an established method for high-precision and high-accuracy distance measurements. It is, however, restricted by an inherent length ambiguity and the requirement for complex control loops for comb stabilization. Here, we present a simple approach for expanding the ambiguity-free measurement length of DC ranging by exploiting the intrinsic intensity modulation of a single-cavity dual-color DC for simultaneous time-of-flight and DC distance measurements. This measurement approach enables the measurement of distances up to several hundred kilometers with the precision and accuracy of a DC interferometric setup while providing a high data acquisition rate (≈2kHz) and requiring only the repetition rate of one of the combs to be stabilized.

9.
Opt Express ; 29(12): 18122-18138, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34154078

RESUMO

We present a direct comparison between two types of femtosecond 2 µm sources used for seeding of an ultrafast thulium-doped fiber amplifier based on all-normal dispersion supercontinuum and soliton self-frequency shift. Both nonlinear effects were generated in microstructured silica fibers, pumped with low-power femtosecond pulses at 1.56 µm originating from an erbium-doped fiber laser. We performed a full characterization of both nonlinear processes, including their shot-to-shot stability, phase coherence, and relative intensity noise. The results revealed that the solitons show comparable performance to supercontinuum in terms of relative intensity noise and shot-to-shot stability, despite the anomalous dispersion regime. Both sources can be successfully used as seeds for Tm-doped fiber amplifiers as an alternative to Tm-doped oscillators. The results show that the sign of chromatic dispersion of the fiber is not crucial for obtaining a stable, high-quality, and low-noise spectral conversion process when pumped with sub-50 fs laser pulses.

10.
Opt Express ; 29(2): 2690-2702, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33726460

RESUMO

We report an investigation of dispersion management of an all-polarization-maintaining Er-fiber oscillator mode-locked via a nonlinear amplification loop mirror in a figure-nine cavity configuration with two output ports. The performance of the laser was investigated within the net cavity dispersion ranging from -0.034 ps2 to +0.006 ps2. We show that the spectral and temporal phase of the pulses at both figure-nine outputs have clearly different characteristics. One of the laser outputs provides pulses with significantly better quality; nonetheless, the rejection output also offers ultrashort pulses with broad spectra. Pulses as short as 79 fs with an energy of 83 pJ were generated directly from the laser in the near-zero dispersion regime.

11.
Phys Rev Lett ; 126(6): 063001, 2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33635699

RESUMO

We report the first measurement of sub-Doppler molecular response using a frequency comb by employing the comb as a probe in optical-optical double-resonance spectroscopy. We use a 3.3 µm continuous wave pump and a 1.67 µm comb probe to detect sub-Doppler transitions to the 2ν_{3} and 3ν_{3} bands of methane with ∼1.7 MHz center frequency accuracy. These measurements provide the first verification of the accuracy of theoretical predictions from highly vibrationally excited states, needed to model the high-temperature spectra of exoplanets. Transition frequencies to the 3ν_{3} band show good agreement with the TheoReTS line list.

12.
Biomed Opt Express ; 11(8): 4431-4442, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32923054

RESUMO

A femtosecond frequency-doubled erbium-doped fiber laser with an adjustable pulse repetition rate is developed and applied in two-photon excited fluorescence microscopy. The all-fiber laser system provides the fundamental pulse at 1560 nm wavelength with 22 fs duration for the second harmonic generation, resulting in 1.35 nJ, 60 fs pulses at 780 nm. The repetition rate is adjusted by a pulse picker unit built-in within the amplifier chain, directly providing transform-limited pulses for any chosen repetition rate between 1 and 12 MHz. We employed the laser source to drive a scanning two-photon excited fluorescence microscope for ex vivo rat skin and other samples' imaging at various pulse repetition rates. Due to compactness, ease of operation, and suitable pulse characteristics, the laser source can be considered as an attractive alternative for Ti:Sapphire laser in biomedical imaging.

13.
Opt Express ; 27(26): 37435-37445, 2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-31878523

RESUMO

A compact and robust all-fiber difference frequency generation-based source of broadband mid-infrared radiation is presented. The source emits tunable radiation in the range between 6.5 µm and 9 µm with an average output power up to 5 mW at 125 MHz repetition frequency. The all-in-fiber construction of the source along with active stabilization techniques results in long-term repetition rate stability of 3 Hz per 10 h and a standard deviation of the output power better than 0.8% per 1 h. The applicability of the presented source to laser spectroscopy is demonstrated by measuring the absorption spectrum of nitrous oxide (N2O) around 7.8 µm. The robustness and good long- and short-term stability of the source opens up for applications outside the laboratory.

14.
Sci Rep ; 9(1): 12313, 2019 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-31444393

RESUMO

We report the generation of coherent octave-spanning supercontinuum in an all-fiber system, without any free-space optical components. The setup uses the femtosecond fiber laser as a pump and an all-normal dispersion microstructured fiber as a medium for supercontinuum generation. The generated spectrum is characterized both experimentally and numerically and shows a broad bandwidth (1.1-2.2 µm), a high signal to noise ratio reaching 100 at maximum, a high coherence (closing to 1), linear polarization and average output power up to 57 mW. The source is characterized by exceptional simplicity and does not require any alignment (the nonlinear fiber is spliced to the pump) which finally opens the path to outside-lab applications of supercontinuum radiation.

15.
Opt Express ; 26(9): 11756-11763, 2018 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-29716094

RESUMO

We report the first fully fiberized difference frequency generation (DFG) source, delivering a broadly tunable idler in the 6 to 9 µm spectral range, using an orientation-patterned gallium phosphide (OP-GaP) crystals with different quasi-phase matching periods (QPM). The mid-infrared radiation (MIR) is obtained via mixing of the output of a graphene-based Er-doped fiber laser at 1.55 µm with coherent frequency-shifted solitons at 1.9 µm generated in a highly nonlinear fiber using the same seed. The presented setup is the first truly all-fiber, all-polarization maintaining, alignment-free DFG source reported so far. Its application to laser spectroscopy was demonstrated by the absorption spectrum measurement of ν4 band of methane in 7.5 - 8.3 µm spectral range. The system simplicity and compactness paves the way for applications in field-deployable optical frequency comb spectroscopy systems for gas sensing.

16.
Sci Rep ; 7: 45491, 2017 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-28368014

RESUMO

In this work, we demonstrate a comprehensive study on the nonlinear parameters of carbon nanotube (CNT) saturable absorbers (SA) as a function of the nanotube film thickness. We have fabricated a set of four saturable absorbers with different CNT thickness, ranging from 50 to 200 nm. The CNTs were fabricated via a vacuum filtration technique and deposited on fiber connector end facets. Each SA was characterized in terms of nonlinear transmittance (i.e. optical modulation depth) and tested in a Thulium-doped fiber laser. We show, that increasing the thickness of the CNT layer significantly increases the modulation depth (up to 17.3% with 200 nm thick layer), which strongly influences the central wavelength of the laser, but moderately affects the pulse duration. It means, that choosing the SA with defined CNT thickness might be an efficient method for wavelength-tuning of the laser, without degrading the pulse duration. In our setup, the best performance in terms of bandwidth and pulse duration (8.5 nm and 501 fs, respectively) were obtained with 100 nm thick CNT layer. This is also, to our knowledge, the first demonstration of a fully polarization-maintaining mode-locked Tm-doped laser based on CNT saturable absorber.

17.
Opt Lett ; 42(9): 1748-1751, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28454151

RESUMO

We demonstrate a broadband mid-infrared (MIR) frequency comb source based on difference frequency generation (DFG) in periodically poled lithium niobate crystal. MIR radiation is obtained via mixing of the output of a 125 MHz repetition rate Yb-doped fiber laser with Raman-shifted solitons generated from the same source in a highly nonlinear fiber. The resulting idler is tunable in the range of 2.7-4.2 µm, with average output power reaching 237 mW and pulses as short as 115 fs. The coherence of the MIR comb is confirmed by spectral interferometry and heterodyne beat measurements. Applicability of the developed DFG source for laser spectroscopy is demonstrated by measuring absorption spectrum of acetylene at 3.0-3.1 µm.

18.
Opt Lett ; 42(8): 1592-1595, 2017 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-28409806

RESUMO

In this Letter, we demonstrate an all-polarization-maintaining, stretched-pulse Tm-doped fiber laser generating ∼200 fs pulses centered at 1945 nm. As a saturable absorber, a graphene/poly(methyl methacrylate) composite was used. To the best of our knowledge, this is the first demonstration of stretched-pulse operation of a graphene-based fiber laser at 2 µm.

19.
Opt Express ; 24(18): 20359-64, 2016 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-27607642

RESUMO

We report on the generation of noise-like pulse (NLP) trains in a Tm-doped fiber laser mode-locked by multilayer graphene saturable absorber. The spectral bandwidth obtained directly from the oscillator exceeds 60 nm, centered at 1950 nm, with 23.5 MHz repetition rate. The pulses were also amplified in a fully fiberized amplifier based on a double-cladding Tm-doped fiber. The system was capable of delivering 1.21 W of average power, which corresponds to 51.5 nJ energy stored in the noise-like bundle. We believe that the presented source might serve as a pump for supercontinuum generation in highly nonlinear fibers.

20.
Opt Lett ; 41(11): 2592-5, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27244422

RESUMO

In this Letter, we demonstrate a graphene mode-locked, all-fiber Ho-doped fiber laser generating 1.3 nJ energy pulses directly from the oscillator. The graphene used as a saturable absorber was obtained via chemical vapor deposition on copper substrate and immersed in a poly(methyl methacrylate) support. The laser generated ultrashort soliton pulses at 2080 nm with bandwidth up to 6.1 nm. The influence of the output coupling ratio and the SA modulation depth on the mode-locking performance was also investigated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...