Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Biomater ; 171: 166-192, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37797709

RESUMO

Cardiac tissue growth and remodelling (G & R) occur in response to the changing physiological demands of the heart after birth. The early shift to pulmonary circulation produces an immediate increase in ventricular workload, causing microstructural and biomechanical changes that serve to maintain overall physiological homoeostasis. Such cardiac G & R continues throughout life. Quantifying the tissue's mechanical and microstructural changes because of G & R is of increasing interest, dovetailing with the emerging fields of personalised and precision solutions. This study aimed to determine equibiaxial, and non-equibiaxial extension, stress-relaxation, and the underlying microstructure of the passive porcine ventricles tissue at four time points spanning from neonatal to adulthood. The three-dimensional microstructure was investigated via two-photon excited fluorescence and second-harmonic generation microscopy on optically cleared tissues, describing the 3D orientation, rotation and dispersion of the cardiomyocytes and collagen fibrils. The results revealed that during biomechanical testing, myocardial ventricular tissue possessed non-linear, anisotropic, and viscoelastic behaviour. An increase in stiffness and viscoelasticity was noted for the left and right ventricular free walls from neonatal to adulthood. Microstructural analyses revealed concomitant increases in cardiomyocyte rotation and dispersion. This study provides baseline data, describing the biomechanical and microstructural changes in the left and right ventricular myocardial tissue during G & R, which should prove valuable to researchers in developing age-specific, constitutive models for more accurate computational simulations. STATEMENT OF SIGNIFICANCE: There is a dearth of experimental data describing the growth and remodelling of left and right ventricular tissue. The published literature is fragmented, with data reported via different experimental techniques using tissues harvested from a variety of animals, with different gender and ages. This prevents developing a continuum of data spanning birth to death, so limiting the potential that can be leveraged to aid computational modelling and simulations. In this study, equibiaxial, non-equibiaxial, and stress-relaxation data are presented, describing directional-dependent material responses. The biomechanical data is consolidated with equivalent microstructural data, an important element for the development of future material models. Combined, these data describe microstructural and biomechanical changes in the ventricles, spanning G &R from neonatal to adulthood.


Assuntos
Ventrículos do Coração , Miocárdio , Animais , Suínos , Miocárdio/química , Miócitos Cardíacos , Matriz Extracelular , Simulação por Computador , Fenômenos Biomecânicos , Estresse Mecânico
2.
J Mech Behav Biomed Mater ; 137: 105536, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36327651

RESUMO

Antimicrobial 3D printed surfaces made of PLA and TPU polymers loaded with copper (Cu), and silver (Ag) nanoparticles (NPs) were developed via fused deposition modeling (FDM). The potential antimicrobial effect of the 3D printed surfaces against Escherichia coli, Listeria monocytogenes, Salmonella Typhimurium, and Staphylococcus aureus was evaluated. Furthermore, the mechanical characteristics, including surface topology and morphology, tensile test of specimens manufactured in three different orientations (XY, XZ, and ZX), water absorption capacity, and surface wettability were also assessed. The results showed that both Cu and Ag-loaded 3D printed surfaces displayed a higher inhibitory effect against S. aureus and L. monocytogenes biofilms compared to S. Typhimurium and E. coli biofilms. The results of SEM analysis revealed a low void fraction for the TPU and no voids for the PLA samples achieved through optimization and the small height (0.1 mm) of the printed layers. The best performing specimen in terms of its tensile was XY, followed by ZX and XZ orientation, while it indicated that Cu and Ag-loaded material had a slightly stiffer response than plain PLA. Additionally, Cu and Ag-loaded 3D printed surfaces revealed the highest hydrophobicity compared to the plain polymers making them excellent candidates for biomedical and food production settings to prevent initial bacterial colonization. The approach taken in the current study offers new insights for developing antimicrobial 3D printed surfaces and equipment to enable their application towards the inhibition of the most common nosocomial and foodborne pathogens and reduce the risk of cross-contamination and disease outbreaks.


Assuntos
Anti-Infecciosos , Infecção Hospitalar , Humanos , Staphylococcus aureus , Escherichia coli , Polímeros , Antibacterianos/farmacologia , Anti-Infecciosos/farmacologia , Poliésteres/farmacologia , Impressão Tridimensional
3.
Biomech Model Mechanobiol ; 18(4): 1213-1232, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30945052

RESUMO

Constitutive laws that describe the mechanical responses of cardiac tissue under loading hold the key to accurately model the biomechanical behaviour of the heart. There have been ample choices of phenomenological constitutive laws derived from experiments, some of which are quite sophisticated and include effects of microscopic fibre structures of the myocardium. A typical example is the strain-invariant-based Holzapfel-Ogden 2009 model that is excellently fitted to simple shear tests. It has been widely used and regarded as the state-of-the-art constitutive law for myocardium. However, there has been no analysis to show if it has both adequate descriptive and predictive capabilities for other tissue tests of myocardium. Indeed, such an analysis is important for any constitutive laws for clinically useful computational simulations. In this work, we perform such an analysis using combinations of tissue tests, uniaxial tension, biaxial tension and simple shear from three different sets of myocardial tissue studies. Starting from the general 14-parameter myocardial constitutive law developed by Holzapfel and Ogden, denoted as the general HO model, we show that this model has good descriptive and predictive capabilities for all the experimental tests. However, to reliably determine all 14 parameters of the model from experiments remains a great challenge. Our aim is to reduce the constitutive law using Akaike information criterion, to maintain its mechanical integrity whilst achieving minimal computational cost. A competent constitutive law should have descriptive and predictive capabilities for different tissue tests. By competent, we mean the model has least terms but is still able to describe and predict experimental data. We also investigate the optimal combinations of tissue tests for a given constitutive model. For example, our results show that using one of the reduced HO models, one may need just one shear response (along normal-fibre direction) and one biaxial stretch (ratio of 1 mean fibre : 1 cross-fibre) to satisfactorily describe Sommer et al. human myocardial mechanical properties. Our study suggests that single-state tests (i.e. simple shear or stretching only) are insufficient to determine the myocardium responses. We also found it is important to consider transmural fibre rotations within each myocardial sample of tests during the fitting process. This is done by excluding un-stretched fibres using an "effective fibre ratio", which depends on the sample size, shape, local myofibre architecture and loading conditions. We conclude that a competent myocardium material model can be obtained from the general HO model using AIC analysis and a suitable combination of tissue tests.


Assuntos
Modelos Biológicos , Miocárdio/patologia , Algoritmos , Animais , Análise de Elementos Finitos , Humanos , Estresse Mecânico , Sus scrofa
4.
J Mech Behav Biomed Mater ; 88: 18-28, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30118921

RESUMO

Neonatal heart disorders represent a major clinical challenge, with congenital heart disease alone affecting 36,000 new-borns annually within the European Union. Surgical intervention to restore normal function includes the implantation of synthetic and biological materials; however, a lack of experimental data describing the mechanical behaviour of neonatal cardiac tissue is likely to contribute to the relatively poor short- and long-term outcome of these implants. This study focused on characterising the mechanical behaviour of neonatal cardiac tissue using a porcine model, to enhance the understanding of how this differs to the equivalent mature tissue. The biomechanical properties of neonatal porcine cardiac tissue were characterised by uniaxial tensile, biaxial tensile, and simple shear loading modes, using samples collected from the anterior and posterior walls of the right and left ventricles. Histological images were prepared using Masson's trichrome staining, to enable assessment of the microstructure and correlation with tissue behaviour. The mechanical tests demonstrated that the neonatal cardiac tissue is non-linear, anisotropic, viscoelastic and heterogeneous. Our data provide a baseline describing the biomechanical behaviour of immature porcine cardiac tissue. Comparison with published data also indicated that the neonatal porcine cardiac tissue exhibits one-half the stiffness of mature porcine tissue in uniaxial extension testing, one-third in biaxial extension testing, and one-fourth stiffness in simple shear testing; hence, it provides an indication as to the relative change in characteristics associated with tissue maturation. These data may prove valuable to researchers investigating neonatal cardiac mechanics.


Assuntos
Ventrículos do Coração , Fenômenos Mecânicos , Animais , Animais Recém-Nascidos , Fenômenos Biomecânicos , Resistência ao Cisalhamento , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...