Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 50(1): 424-439, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36412161

RESUMO

BACKGROUND: Boron Neutron Capture Therapy (BNCT) has recently been used in clinical oncology thanks to recent developments of accelerator-based BNCT systems. Although there are some specific processes for BNCT, they have not yet been discussed in detail. PURPOSE: The aim of this study is to provide comprehensive data on the risk of accelerator-based BNCT system to institutions planning to implement an accelerator-based BNCT system. METHODS: In this study, failure mode and effects analysis (FMEA) was performed based on a treatment process map prepared for the accelerator-based BNCT system. A multidisciplinary team consisting of a medical doctor (MD), a registered nurse (RN), two medical physicists (MP), and three radiologic technologists (RT) identified the failure modes (FMs). Occurrence (O), severity (S), and detectability (D) were scored on a scale of 10, respectively. For each failure mode (FM), risk priority number (RPN) was calculated by multiplying the values of O, S, and D, and it was then categorized as high risk, very high risk, and other. Additionally, FMs were statistically compared in terms of countermeasures, associated occupations, and whether or not they were the patient-derived. RESULTS: The identified FMs for BNCT were 165 in which 30 and 17 FMs were classified as high risk and very high risk, respectively. Additionally, 71 FMs were accelerator-based BNCT-specific FMs in which 18 and 5 FMs were classified as high risk and very high risk, respectively. The FMs for which countermeasures were "Education" or "Confirmation" were statistically significantly higher for S than the others (p = 0.019). As the number of BNCT facilities is expected to increase, staff education is even more important. Comparing patient-derived and other FMs, O tended to be higher in patient-derived FMs. This could be because the non-patient-derived FMs included events that could be controlled by software, whereas the patient-derived FMs were impossible to prevent and might also depend on the patient's condition. Alternatively, there were non-patient-derived FMs with higher D, which were difficult to detect mechanically and were classified as more than high risk. In O, significantly higher values (p = 0.096) were found for FMs from MD and RN associated with much patient intervention compared to FMs from MP and RT less patient intervention. Comparing conventional radiotherapy and accelerator-based BNCT, although there were events with comparable risk in same FMs, there were also events with different risk in same FMs. They could be related to differences in the physical characteristics of the two modalities. CONCLUSIONS: This study is the first report for conducting a risk analysis for BNCT using FMEA. Thus, this study provides comprehensive data needed for quality assurance/quality control (QA/QC) in the treatment process for facilities considering the implementation of accelerator-based BNCT in the future. Because many BNCT-specific risks were discussed, it is important to understand the characteristics of BNCT and to take adequate measures in advance. If the effects of all FMs and countermeasures are discussed by multidisciplinary team, it will be possible to take countermeasures against individual FMs from many perspectives and provide BNCT more safely and effectively.


Assuntos
Terapia por Captura de Nêutron de Boro , Análise do Modo e do Efeito de Falhas na Assistência à Saúde , Humanos , Medição de Risco , Controle de Qualidade
2.
J Radiat Res ; 64(1): 186-194, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36316958

RESUMO

This study aimed to clarify the differences in radiotherapy dose characteristics and delivery efficiency between the supine and prone positions in patients with prostate cancer using the CyberKnife. The planning computed tomography (CT) and delineations of the prone position were obtained by rotating the supine CT images with delineations of 180° using image processing software. The optimization parameters for planning target volume (PTV) and organs at risk (OARs) were based on the prone position. The optimization parameters determined for the prone position were applied to the supine position for optimization and dose calculation. The dosimetric characteristics of the PTV and OARs, and delivery efficiency were compared between the two different patient positions. The plans in the prone position resulted in better PTV conformity index (nCI), rectum V90%, V80%, V75%, V50% and bladder V50%. A significant difference was observed in treatment time and depth along the central axis (dCAX) between the two plans. The mean treatment time per fraction and dCAX for the supine and prone positions were 20.9 ± 1.7 min versus 19.8 ± 1.3 min (P = 0.019) and 151.1 ± 33.6 mm versus 233.2 ± 8.8 mm (P < 0.001), respectively. In this study the prone position was found to improve dosimetric characteristics and delivery efficiency compared with the supine position during prostate cancer treatment with the CyberKnife.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Masculino , Humanos , Próstata , Radioterapia Conformacional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Decúbito Dorsal , Dosagem Radioterapêutica , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Órgãos em Risco , Decúbito Ventral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...