Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(9): 16090-16102, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38859246

RESUMO

In this study, we developed a rigid-scope system that can perform hyperspectral imaging (HSI) between visible and 1600 nm wavelengths using a supercontinuum light source and an acousto-optic tunable filter to emit specific wavelengths. The system optical performance was verified, and the classification ability was investigated. Consequently, it was demonstrated that HSI (490-1600 nm) could be performed. In addition, seven different targets could be classified by the neural network with an accuracy of 99.6%, recall of 93.7%, and specificity of 99.1% when the wavelength range of over 1000 nm (OTN) was extracted from HSI data as train data.

2.
ACS Appl Bio Mater ; 7(6): 3821-3827, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38787698

RESUMO

Near-infrared fluorescence (NIRF) thermometry is an emerging method for the noncontact measurement of in vivo deep temperatures. Fluorescence-lifetime-based methods are effective because they are unaffected by optical loss due to excitation or detection paths. Moreover, the physiological changes in body temperature in deep tissues and their pharmacological effects are yet to be fully explored. In this study, we investigated the potential application of the NIRF lifetime-based method for temperature measurement of in vivo deep tissues in the abdomen using rare-earth-based particle materials. ß-NaYF4 particles codoped with Nd3+ and Yb3+ (excitation: 808 nm, emission: 980 nm) were used as NIRF thermometers, and their fluorescence decay curves were exponential. Slope linearity analysis (SLA), a screening method, was proposed to extract pixels with valid data. This method involves performing a linearity evaluation of the semilogarithmic plot of the decay curve collected at three delay times after cutting off the pulsed laser irradiation. After intragastric administration of the thermometer, the stomach temperature was monitored by using an NIRF time-gated imaging setup. Concurrently, a heater was attached to the lower abdomens of the mice under anesthesia. A decrease in the stomach temperature under anesthesia and its recovery via the heater indicated changes in the fluorescence lifetime of the thermometer placed inside the body. Thus, NaYF4:Nd3+/Yb3+ functions as a fluorescence thermometer that can measure in vivo temperature based on the temperature dependence of the fluorescence lifetime at 980 nm under 808 nm excitation. This study demonstrated the ability of a rare-earth-based NIRF thermometer to measure deep tissues in live mice, with the proposed SLA method for excluding the noisy deviations from the analysis for measuring temperature using the NIRF lifetime of a rare-earth-based thermometer.


Assuntos
Fluoretos , Imagem Óptica , Itérbio , Ítrio , Animais , Camundongos , Ítrio/química , Itérbio/química , Fluoretos/química , Neodímio/química , Materiais Biocompatíveis/química , Teste de Materiais , Tamanho da Partícula , Temperatura , Termometria/métodos , Raios Infravermelhos
3.
Anal Sci ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619813

RESUMO

Luminescence thermometry is a non-contact method that can measure surface temperatures and the temperature of the area where the fluorescent probe is located, allowing temperature distribution visualizations with a camera. Ratiometric fluorescence thermometry, which uses the intensity ratio of fluorescence peaks at two wavelengths with different fluorescence intensity dependencies, is an excellent method for visualizing temperature distributions independent of the fluorophore spatial concentration, excitation light intensity and absolute fluorescence intensity. Herein, Nd3+/Yb3+/Er3+-doped Y2O3 nanomaterials with a diameter of 200 nm were prepared as phosphors for temperature distribution measurement of fluids at different temperatures. The advantages of this designed fluorescent material include non-aggregation in water and the fact that its near-infrared (NIR) fluorescence excitation (808 nm) is not absorbed by water, thereby minimizing sample heating upon irradiation. Under optical excitation at 808 nm, the ratio of the fluorescence intensities of Yb3+ (IYb; 975 nm) and Er3+ (IEr; 1550 nm), which exhibited different temperature responses, indicated the temperature distribution inside the fluid device. Thus, this technique using Nd3+/Yb3+/Er3+-doped Y2O3 is expected to be applied for temperature distribution mapping analysis inside fluidic devices as a ratiometric NIR fluorescence thermometer, which is unaffected by laser-induced heating.

4.
J Biomed Mater Res B Appl Biomater ; 112(1): e35327, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37732480

RESUMO

Micelles have been extensively used in biomedicine as potential carriers of hydrophobic fluorescent dyes. Their small diameters can potentially enable them to evade recognition by the reticuloendothelial system, resulting in prolonged circulation. Nevertheless, their lack of stability in physiological environments limits the imaging utility of micelles. In particular, when a dye sensitive to water, such as IR-1061, is encapsulated in the micelle core, the destabilized structure leads to interactions between water and dye, degrading the fluorescence. In this study, we investigated a method to improve micelle stability utilizing the electrical effect of gadolinium (Gd3+ ) and tetraazacyclododecane tetraacetic acid (DOTA), introduced into the micelles. Three micellar structures, one containing a poly(lactic-co-glycolic acid)-block-poly(ethylene glycol) (PLGA-b-PEG) block copolymer, and two other structures, including PLGA-b-PEG with DOTA or Gd-DOTA introduced at the boundary of PLGA and PEG, were prepared with IR-1061 in the core. Structures that contained DOTA at the border of the PLGA core and PEG shell exhibited much higher fluorescence intensity than probes without DOTA. With Gd3+ ions at the DOTA center, fluorescence stability was enhanced remarkably in physiological environments. Most interesting is the finding that fluorescence is enhanced with increased Gd-DOTA concentrations. In conclusion, we found that overall fluorescence and stability are improved by introducing Gd-DOTA at the boundary of the PLGA core and PEG shell. Improving micelle stability is crucial for further biomedical applications of micellar probes such as bimodal fluorescence and magnetic resonance imaging.


Assuntos
Boratos , Compostos Heterocíclicos , Lactatos , Micelas , Compostos Organometálicos , Polietilenoglicóis , Piranos , Fluorescência , Polietilenoglicóis/química , Poliglactina 910/química , Água/química
5.
Sci Rep ; 13(1): 20555, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996472

RESUMO

Fatty acids play various physiological roles owing to their diverse structural characteristics, such as hydrocarbon chain length (HCL) and degree of saturation (DS). Although the distribution of fatty acids in biological tissues is associated with lipid metabolism, in situ imaging tools are still lacking for HCL and DS. Here, we introduce a framework of near-infrared (1000-1400 nm) hyperspectral label-free imaging with machine learning analysis of the fatty acid HCL and DS distribution in the liver at each pixel, in addition to the previously reported total lipid content. The training data of 16 typical fatty acids were obtained by gas chromatography from liver samples of mice fed with various diets. A two-dimensional mapping of these two parameters was successfully performed. Furthermore, the HCL/DS plot exhibited characteristic clustering among the different diet groups. Visualization of fatty acid distribution would provide insights for revealing the pathophysiological conditions of liver diseases and metabolism.


Assuntos
Ácidos Graxos , Imageamento Hiperespectral , Camundongos , Animais , Ácidos Graxos/metabolismo , Fígado/metabolismo
7.
J Biomed Opt ; 28(8): 086001, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37614567

RESUMO

Significance: Determining the extent of gastric cancer (GC) is necessary for evaluating the gastrectomy margin for GC. Additionally, determining the extent of the GC that is not exposed to the mucosal surface remains difficult. However, near-infrared (NIR) can penetrate mucosal tissues highly efficiently. Aim: We investigated the ability of near-infrared hyperspectral imaging (NIR-HSI) to identify GC areas, including exposed and unexposed using surgical specimens, and explored the identifiable characteristics of the GC. Approach: Our study examined 10 patients with diagnosed GC who underwent surgery between 2020 and 2021. Specimen images were captured using NIR-HSI. For the specimens, the exposed area was defined as an area wherein the cancer was exposed on the surface, the unexposed area as an area wherein the cancer was present although the surface was covered by normal tissue, and the normal area as an area wherein the cancer was absent. We estimated the GC (including the exposed and unexposed areas) and normal areas using a support vector machine, which is a machine-learning method for classification. The prediction accuracy of the GC region in every area and normal region was evaluated. Additionally, the tumor thicknesses of the GC were pathologically measured, and their differences in identifiable and unidentifiable areas were compared using NIR-HSI. Results: The average prediction accuracy of the GC regions combined with both areas was 77.2%; with exposed and unexposed areas was 79.7% and 68.5%, respectively; and with normal regions was 79.7%. Additionally, the areas identified as cancerous had a tumor thickness of >2 mm. Conclusions: NIR-HSI identified the GC regions with high rates. As a feature, the exposed and unexposed areas with tumor thicknesses of >2 mm were identified using NIR-HSI.


Assuntos
Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia , Imageamento Hiperespectral , Diagnóstico por Imagem , Aprendizado de Máquina
8.
ACS Appl Bio Mater ; 6(7): 2644-2650, 2023 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-37345801

RESUMO

We developed a small MRI/NIR-II probe to target HER2 (tetanucleotide) breast cancer cells. The probe is composed of PLGA-b-PEG micelles encapsulated NIR-II, and Gd-DOTA is conjugated at the border of PLGA/PEG. Herceptin was then conjugated to carboxyl residues of PLGA-b-PEG chains. We examined the influence of carboxyl group ratios on the probe property stability and Herceptin concentration and the binding affinity to HER2(+) cells corresponding to the -COOH ratios. The binding assays demonstrated that the optimal surface ratio of -COOH is 5%, which is less affected by fluorescence reduction and which exhibited the highest antigen-capturing activity.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Trastuzumab/farmacologia , Trastuzumab/uso terapêutico , Trastuzumab/química , Micelas , Imageamento por Ressonância Magnética
9.
Biomed Mater Devices ; : 1-13, 2023 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-37363140

RESUMO

Polymeric nanoparticles with a hydrophobic core are valuable biomedical materials with potential applications in in vivo imaging and drug delivery. These materials are effective at protecting vulnerable molecules, enabling them to serve their functions in hydrophilic physiological environments; however, strategies that allow the chemical composition and molecular weight of polymers to be tuned, forming nanoparticles to control the functional molecules, are lacking. In this article, we review strategies for designing core-shell nanoparticles that enable the effective and stable encapsulation of functional molecules for biomedical applications. IR-1061, which changes its optical properties in response to the microenvironment are useful for in vitro screening of the in vivo stability of polymeric nanoparticles. An in vitro screening test can be performed by dispersing IR-1061-encapsulated polymer nanoparticles in water, saline, buffer solution, aqueous protein solution, etc., and measuring the absorption spectral changes. Through the screening, the effects of the polarity, molecular weight, and the chiral structure of polymers consisting of polymer nanoparticles on their stability have been revealed. Based on the findings presented here, more methodologies for the effective application of various biomolecules and macromolecules with complex high-dimensional structures are expected to be developed.

10.
Biomater Sci ; 10(21): 6244-6257, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36106960

RESUMO

Multimodal imaging is attractive in biomedical research because it can provide multidimensional information about objects that individual techniques cannot accomplish. In particular, combining over one-thousand-nanometer near-infrared (OTN-NIR) fluorescence and magnetic resonance (MR) imaging is promising for detecting lesions with high sensitivity and structural information. Herein, we describe the development of a bimodal OTN-NIR/MRI probe from gadolinium-tetraazacyclododecanetetraacetic acid (Gd-DOTA) conjugated poly(lactic-co-glycolic acid)-block-poly(ethylene glycol) copolymer (PLGA-b-PEG) micelle encapsulated IR-1061 at two different locations. One configuration contains Gd-DOTA at the end of the PEG of the hydrophilic shell and the other contains Gd-DOTA at the border of PLGA/PEG. The two structures show remarkable differences in fluorescence and R1 relaxation rates in biological environments; the structure with Gd-DOTA at the border of PLGA/PEG exhibits stable fluorescence and T1 signal distribution in live mice. The introduction ratio of Gd-DOTA to PEG is significant for controlling the properties of both structures; a higher Gd-DOTA ratio is preferable for the contrast enhancement effect. We found that Gd-DOTA ratios higher than 10% degraded the fluorescence intensity when Gd-DOTA was bound to the end of PEG. In contrast, the introduction of 70% Gd-DOTA at the border of PLGA/PEG did not exhibit a degraded signal, and the structural stability was enhanced with higher ratios of Gd-DOTA. In conclusion, we confirmed that the location of Gd-DOTA is a crucial factor in designing high-performance probes. The overall properties improve when Gd-DOTA is set on the border of PLGA/PEG. These improvements in the properties by controlling the probe structures are promising for future biomedical applications.


Assuntos
Gadolínio , Micelas , Camundongos , Animais , Gadolínio/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Fluorescência , Polietilenoglicóis/química , Imageamento por Ressonância Magnética/métodos
11.
Biomed Mater Eng ; 33(6): 453-463, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35662100

RESUMO

BACKGROUND: Most orthodontic cases consist of varying degrees of crowding. To manage crowded dentitions, nickel-titanium archwires with various ligation methods are often used. OBJECTIVE: We aimed to investigate the effect of different ligation methods with respect to force and moment and suggest the efficient ligation method for treating rotation and displacement simultaneously. METHODS: We built a model that simulated the three anterior teeth of the maxilla. The teeth on the two ends were fixed, and the middle tooth was set in several different positions by manipulating the amount of displacement in bucco-lingual direction and rotation angle. The measurements were taken with three different ligation methods of self-ligation (SL), elastomeric o-ring ligation on both side wings (EB), and on one side wings (EO). RESULTS: The magnitude of linguo-buccal force exceeded the standard optimal force in each condition examined and was significantly larger in EB than in other ligation methods. Moreover, the magnitude of moment generation with SL was suitable in the 0.0 mm linguo-version, whereas it was suitable with EO in the linguo-version ranging 1.0-3.0 mm. CONCLUSIONS: The ligation method significantly affected the force and moment. SL and EO are recommended in dentitions with light and deep lingual displacements, respectively.


Assuntos
Maxila , Braquetes Ortodônticos , Maxila/cirurgia , Fios Ortodônticos , Desenho de Aparelho Ortodôntico , Técnicas de Movimentação Dentária/métodos , Dentição , Rotação , Incisivo
12.
RSC Adv ; 12(3): 1310-1318, 2022 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-35425212

RESUMO

Over-thousand-nanometer (OTN) near-infrared (NIR) fluorophores are useful for biological deep imaging because of the reduced absorption and scattering of OTN-NIR light in biological tissues. IR-1061, an OTN-NIR fluorescent dye, has a hydrophobic and cationic backbone in its molecular structure, and a non-polar counter ion, BF4 -. Because of its hydrophobicity, IR-1061 needs to be encapsulated in a hydrophobic microenvironment, such as a hydrophobic core of polymer micelles, shielded with a hydrophilic shell for bioimaging applications. Previous studies have shown that the affinity of dyes with hydrophobic core polymers is dependent on the polarity of the core polymer, and that this characteristic is important for designing dye-encapsulated micelles to be used in bioimaging. In this study, the dye-polymer affinity was investigated using hydrophobic polymer films with different chiral structures of poly(lactic acid). IR-1061 showed higher affinity for l- and d-lactic acid copolymers (i.e., poly(dl-lactic acid) (PDLLA)) than to poly(l-lactic acid) (PLLA), as IR-1061 shows less dimerization in PDLLA than in PLLA. In contrast, the stability of IR-1061 in PDLLA was less than that in PLLA due to the influence of hydroxyl groups. Choosing hydrophobic core polymers for their robustness and dye affinity is an effective strategy to prepare OTN-NIR fluorescent probes for in vivo deep imaging.

13.
Anal Sci ; 38(1): 199-205, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35287223

RESUMO

Polymeric micellar nanoparticles (PNPs) composed of an amphiphilic block copolymer formed from hydrophilic and hydrophobic blocks and over-thousand-nanometer (OTN) near-infrared (NIR) fluorescent dye are promising fluorophores for the dynamic imaging of deep tissue. In this study, we examined the effect of the ratio of hydrophilic/hydrophobic blocks of a block copolymer, poly(ethylene glycol) (PEG)-b-poly(lactide-co-glycolide) (PLGA), on the properties of OTN-PNPs encapsulating IR-1061. OTN-PNPs with a higher molecular weight of PLGA cores showed higher emission and stabilities under physiological conditions. The PEG ratio to PLGA in the block copolymer decreased the stability of OTN-PNPs probably due to the invasion of water molecules into the polymer core. The results show that the in vivo stability and fluorescence properties can be tuned by adjusting the chain lengths of block copolymers and estimated using in vitro assays, which evaluates the brightness retention rate of the OTN-PNPs under physiological conditions.


Assuntos
Micelas , Nanopartículas , Fluorescência , Corantes Fluorescentes , Nanopartículas/química , Polietilenoglicóis/química , Polímeros/química
14.
ACS Omega ; 7(7): 5817-5824, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35224342

RESUMO

Organic molecules that emit near-infrared (NIR) fluorescence at wavelengths above 1000 nm, also known as the second NIR (NIR-II) biological window, are expected to be applied to optical in vivo imaging of deep tissues. The study of molecular states of NIR-II dye and its optical properties are important to yield well-controlled fluorescent probes; however, no such study has been conducted yet. Among the two major absorption peaks of the NIR-II dye, IR-1061, the ratio of the shorter wavelength (900 nm) to the longer one (1060 nm) increased with an increase in the dye concentration in tetrahydrofuran, suggesting that the 900 nm peak is due to the dimer formation of IR-1061. Both absorption peaks are also observed when IR-1061 is encapsulated in the hydrophobic (stearyl) core of micellar nanoparticles (MNPs) of a phospholipid-poly(ethylene glycol). The dimers in the MNP cores decreased via dimer dissociation by enhancing the mobility of the hydrophobic stearyl chains by heat treatment of the dye-encapsulating MNPs at 50-70 °C. The MNPs maintained the dissociated IR-1061 monomers in the core after recooling to 25 °C and showed a higher NIR-II fluorescence intensity than those before heat treatment. This concept will provide better protocols for the preparation of NIR-II fluorescent probes with well-controlled fluorescence properties.

15.
Appl Opt ; 61(2): 638-644, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35200907

RESUMO

The refraction of fluorescence from the inside of a sample at the surface results in fluctuations in fluorescence computed tomography (CT). We evaluated the influence of the difference in refractive index (RI) between the sample body and the surroundings on fluorescence CT results. The brightest fluorescent point is away from the correct point on the tomograms owing to the refraction. The speculated position is determined as the exact point if the RI ratio ranges between 0.97 and 1.03 by immersing the body in an RI matching liquid. The results can help in experimental settings of fluorescence CT for acquiring three-dimensional positional information.


Assuntos
Refratometria , Tomografia , Refração Ocular , Tomografia Computadorizada por Raios X
16.
Biomater Sci ; 10(5): 1217-1230, 2022 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-35072181

RESUMO

Multimodal imaging can provide multidimensional information for understanding concealed microstructures or bioprocesses in biological objects. The combination of over-1000 nm near-infrared (OTN-NIR) fluorescence imaging and magnetic resonance (MR) imaging is promising in providing high sensitivity and structural information of lesions. This combination can be facilitated by the development of an imaging probe. The OTN-NIR and MR bimodal fluorescence probes reported to date primarily involve ceramic particles for fluorescence and MRI contrast enhancement effect. In this study, we designed a new bimodal OTN-NIR/MR imaging probe from organic components including an OTN-NIR fluorescent organic dye (IR-1061) encapsulated in the core of a micelle composed of poly(lactic-co-glycolic acid)-block-poly(ethylene glycol) copolymer (PLGA-PEG). For the MRI contrast, gadobutrol (Gd-DOTA) was introduced at the end of the PEG chain at various ratios. Thereafter, the OTN-NIR fluorescence and MR bimodal imaging probes of ca. 20 nm in size were successfully prepared and applied in mouse imaging. The probe exhibited absorption and emission in the OTN-NIR, and T1 contrast enhancement effects on MRI. Moreover, it demonstrated bright OTN-NIR fluorescence and MRI contrast enhancement to depict veins and observe the organs in live mice. The imaging results revealed that the Gd-DOTA introduction ratio is of great importance for controlling the biological response of the probe without reducing the contrast enhancement effect.


Assuntos
Imageamento por Ressonância Magnética , Micelas , Animais , Boratos , Corantes Fluorescentes/química , Compostos Heterocíclicos , Imageamento por Ressonância Magnética/métodos , Camundongos , Compostos Organometálicos , Piranos
17.
Biomedicines ; 9(11)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34829811

RESUMO

Near infrared (NIR) light offers high transparency in biological tissue. Recent advances in NIR fluorophores including organic dyes and lanthanide-doped inorganic nanoparticles have realized the effective use of the NIR optical window for in vivo bioimaging and photodynamic therapy. The narrow energy level intervals used for electronic transition that involves NIR light, however, give rise to a need for guidelines for reducing heat emission in luminescence systems, especially in the development of organic/inorganic hybrid structures. This review presents an approach for employing the polarity and vibrational energy of ions and molecules that surround the luminescence centers for the development of such hybrid nanostructures. Multiphonon relaxation theory, formulated for dealing with heat release in ionic solids, is applied to describe the vibrational energy in organic or molecular systems, referred to as phonon in this review, and we conclude that surrounding the luminescence centers either with ions with low vibrational energy or molecules with small chemical polarity is the key to bright luminescence. NIR photoexcited phosphors and nanostructures in organic/inorganic mixed systems, designed based on the guidelines, for photodynamic therapy are reviewed.

19.
Mucosal Immunol ; 14(6): 1335-1346, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34326478

RESUMO

Intestinal inflammation can be accompanied by osteoporosis, but their relationship, mediated by immune responses, remains unclear. Here, we investigated a non-IgE-mediated food-allergic enteropathy model of ovalbumin (OVA) 23-3 mice expressing OVA-specific T-cell-receptor transgenes. Mesenteric lymph nodes (MLNs) and their pathogenic CD4+T cells were important to enteropathy occurrence and exacerbation when the mice were fed an egg-white (EW) diet. EW-fed OVA23-3 mice also developed bone loss and increased CD44hiCD62LloCD4+T cells in the MLNs and bone marrow (BM); these changes were attenuated by MLN, but not spleen, resection. We fed an EW diet to F1 cross offspring from OVA23-3 mice and a mouse line expressing the photoconvertible protein KikGR to track MLN CD4+T cells. Photoconverted MLN CD44hiCD62LloCD4+T cells migrated predominantly to the BM; pit formation assay proved their ability to promote bone damage via osteoclasts. Significantly greater expression of IL-4 mRNA in MLN CD44hiCD62LloCD4+T cells and bone was observed in EW-fed OVA23-3 mice. Anti-IL-4 monoclonal antibody injection canceled bone loss in the primary inflammation phase in EW-fed mice, but less so in the chronic phase. This novel report shows the specific inflammatory relationship, via Th2-dominant-OVA-specific T cells and IL-4 production, between MLNs and bone, a distant organ, in food-allergic enteropathy.


Assuntos
Reabsorção Óssea/etiologia , Linfócitos T CD4-Positivos/fisiologia , Hipersensibilidade Alimentar/complicações , Hipersensibilidade Alimentar/imunologia , Interleucina-4/genética , Enteropatias/imunologia , Linfonodos/imunologia , Células T de Memória/fisiologia , Animais , Biomarcadores , Reabsorção Óssea/diagnóstico por imagem , Reabsorção Óssea/metabolismo , Reabsorção Óssea/patologia , Citocinas/genética , Citocinas/metabolismo , Modelos Animais de Doenças , Suscetibilidade a Doenças , Hipersensibilidade Alimentar/metabolismo , Imunofenotipagem , Interleucina-4/metabolismo , Enteropatias/complicações , Enteropatias/metabolismo , Linfonodos/metabolismo , Mesentério , Camundongos , Modelos Biológicos
20.
Sensors (Basel) ; 21(8)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918935

RESUMO

In this study, a laparoscopic imaging device and a light source able to select wavelengths by bandpass filters were developed to perform multispectral imaging (MSI) using over 1000 nm near-infrared (OTN-NIR) on regions under a laparoscope. Subsequently, MSI (wavelengths: 1000-1400 nm) was performed using the built device on nine live mice before and after tumor implantation. The normal and tumor pixels captured within the mice were used as teaching data sets, and the tumor-implanted mice data were classified using a neural network applied following a leave-one-out cross-validation procedure. The system provided a specificity of 89.5%, a sensitivity of 53.5%, and an accuracy of 87.8% for subcutaneous tumor discrimination. Aggregated true-positive (TP) pixels were confirmed in all tumor-implanted mice, which indicated that the laparoscopic OTN-NIR MSI could potentially be applied in vivo for classifying target lesions such as cancer in deep tissues.


Assuntos
Laparoscopia , Espectroscopia de Luz Próxima ao Infravermelho , Animais , Laparoscópios , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...