Bioengineering (Basel) ; 11(6)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38927795

RESUMO

INTRODUCTION: In recent years, tooth whitening has become one of the most popular ways of achieving the original tooth color. The effect of whitening gel can be improved through heat, light or laser. The bond strength between the enamel and the composite can be reduced through bleaching and laser radiation. The purpose of this study is to assess the shear bond strength of resin composite to enamel after a bleaching process using hydrogen peroxide, with and without a laser (970 nm and 445 nm lasers). METHOD: This study used 51 extracted anterior teeth without caries that were divided into three groups. A 40% hydrogen peroxide gel was used on the enamel of all teeth. The control group received bleaching without a laser. Both the second and third treatment groups received bleaching with a laser, one with 970 nm and the other with 445 nm. After the bleaching process, all groups had etching, bonding and curing of the composite performed. Lastly, the shear bond strength between the enamel and the composite was measured and the failure modes were recorded. The data were compared using a one-way ANOVA test. RESULTS: The mean shear bond strength between the enamel and the composite in the 445 nm group three (445 nanometer) was significantly lower than the other groups (p < 0.05). There was no significant difference between the control and the 970 nm groups (p = 0.2). CONCLUSION: According to the laser wavelengths and parameters that were used in this study and the results of this study, office bleaching with a 445 nm laser weakened the shear bond strength between the enamel and the composite.

2.
Int J Prosthodont ; 37(2): 173-180, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38648165

RESUMO

PURPOSE: To evaluate the marginal integrity of three inlay-retained fixed dental prosthesis (IRFDP) designs fabricated using monolithic zirconia. MATERIALS AND METHODS: In total, 30 IRFDPs were fabricated using 4-YTZP monolithic zirconia and randomly divided into three groups according to the cavity design. Groups ID2 and ID1.5 received an inlay cavity preparation, which includes a proximal box and an occlusal extension with a depth of 2 mm or 1.5 mm, respectively. Group PB received a proximal box cavity preparation without an occlusal extension. The restorations were fabricated and cemented using a dual-cure resin cement (Panavia V5) and subjected to an equivalent of 5 years of aging. The specimens were evaluated under an SEM to measure marginal continuity before and after the aging process. RESULTS: During the whole 5-year aging process, no specimens showed signs of cracking, fracture, or loss of retention in any restorations. In the SEM analysis, most marginal defects observed in the restorations were areas of microgaps at the tooth/cement interface (TC) or zirconia/cement interface (ZC), resulting in loss of adaptation. There was a significant difference between the groups after the aging process at both the TC (F = 4.762, P < .05) and ZC (F = 6.975, P < .05), with Group ID2 presenting the best performance. There was a significant difference between TC and ZC in all groups (P < .05), with ZC presenting more gaps in all groups. CONCLUSIONS: Inlay cavity designs including a proximal box and an occlusal extension exhibited better marginal stability than a proximal box without occlusal extension.


Assuntos
Restaurações Intracoronárias , Zircônio , Zircônio/química , Humanos , Técnicas In Vitro , Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Planejamento de Dentadura , Prótese Parcial Fixa , Materiais Dentários/química
3.
J Clin Exp Dent ; 16(2): e111-e123, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38496810

RESUMO

Background: The 24-month clinical performance of 3 commercially available flowable bulk-fill resin composites in Class III restorations was evaluated. Material and Methods: Forty-two patients, 27 females (64.3%) and 15 (35.7%) males, received at least 3 Class III restorations that never exceeded 4 mm depth and width. One hundred thirty-eight teeth, divided up into three groups (n=46), were randomly restored with Admira Fusion x-base (AFB), Estelite Bulk Fill Flow (EBF) and SDR flow+ (SDR) in one single increment. A 2-step self-etch adhesive system Clearfil SE Bond (C-SE) with selective enamel etching was used for all restorations. The restorations were clinically evaluated using a slightly modified USPHS criteria at the baseline and every 6 months for 24 months. Success rates of each material between the baseline and at 24 months were compared with the McNemar test. At each timepoint, the comparison of the clinical performance among materials in terms of the ratings of the considered criteria was analyzed by using the Friedman and Cochran's Q tests. Results: At the end of the 24-month follow-up, the overall clinical success rate was 100% for each tested material. However, significant differences among the composites were highlighted for several criteria involving the marginal adaptation, marginal discoloration, surface texture, surface staining and color match. Conclusions: The flowable bulk-fill resin composites tested showed an overall good effectiveness for Class III restorations after the 24 months, although significant rating differences among the materials emerged for some specific clinical criteria. Key words:Bulk-fill, Class III restoration, flowable composite, clinical study, self-etching adhesive.

4.
Pharmaceutics ; 15(11)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38004605

RESUMO

OBJECTIVES: This study investigates the efficacy of antimicrobial photodynamic therapy (aPDT) using riboflavin and a blue diode laser (BDL), combined with shock wave-enhanced emission photoacoustic streaming (SWEEPS), against Enterococcus faecalis. MATERIALS AND METHODS: A total of 48 extracted single-rooted human teeth were used. The root canals were instrumented, sealed at their apices, had the smear layer removed, and then underwent autoclave sterilization. Subsequently, each canal was inoculated with E. faecalis bacterial suspension and allowed to incubate for ten days. After confirming the presence of biofilms through scanning electron microscopy (SEM) in three teeth, the remaining teeth were randomly allocated into nine groups, each containing five teeth: control, 5.25% sodium hypochlorite (NaOCl), BDL, SWEEPS + normal saline, SWEEPS + NaOCl, riboflavin, riboflavin + SWEEPS, riboflavin + BDL, and riboflavin + BDL + SWEEPS. After the treatment, the numbers of colony-forming units (CFUs)/mL were calculated. The data were analysed using one-way ANOVA followed by Tukey's test for comparisons. RESULTS: All groups, with the exception of the BDL group, exhibited a significant reduction in E. faecalis CFU/mL when compared to the control group (p < 0.001). The difference in CFU/mL value between riboflavin + BDL + SWEEPS and riboflavin + SWEEPS was significant (p = 0.029), whereas there was no significant difference between riboflavin + BDL + SWEEPS and riboflavin + BDL (p = 0.397). Moreover, there was no statistically significant difference between the riboflavin + SWEEPS group and the riboflavin + BDL group (p = 0.893). CONCLUSIONS: The results demonstrated that combining the SWEEPS technique with riboflavin as a photosensitizer activated by BDL in aPDT effectively reduced the presence of E. faecalis in root canals.

5.
Int J Prosthodont ; 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37222544

RESUMO

PURPOSE: To evaluate the marginal integrity of three inlay-retained fixed dental prosthesis (IRFDP) designs fabricated using monolithic zirconia. MATERIALS AND METHODS: Thirty inlay-retained fixed dental prostheses were fabricated using a 4-YTZP monolithic zirconia, and divided randomly into 3 groups according to the cavity design. Group ID2 and ID1.5 received an inlay cavity preparation which includes a proximal box and an occlusal extension with a depth of 2 mm or 1.5 mm respectively. Group PB received a proximal box cavity preparation without an occlusal extension. The restorations were fabricated and cemented using a dual cure resin cement (Panava V5) and subjected to an equivalent of 5 years of ageing. The specimens were evaluated under a SEM to measure marginal continuity before and after the ageing process. RESULTS: During the whole 5-year ageing process, no specimens showed signs of cracking,fracture or loss of retention in any of the restorations. In the SEM analysis, most of the marginal defects observed in the restorations were areas of micro-gaps at the TC (tooth/cement interface) or ZC (zirconia/cement interface) resulting in loss of adaptation. There was a significant difference between the groups after the ageing process at both the TC (F=4.762, p<.05) and ZC (F=6.975, p<.05), with group ID2 presenting the best performance. There was a significant difference between TC and ZC in all groups (p<.05) with ZC presenting more gaps in all groups. CONCLUSION: Inlay cavity design including a proximal box and an occlusal extension exhibited better marginal stability than a proximal box without occlusal extension.

6.
J Clin Med ; 12(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36675537

RESUMO

Aim: The aim of the present study was to investigate modifications in electromyographic activity of temporal and masseter muscles before and after surgically assisted rapid maxillary expansion (SARME) in adult subjects. Materials and Methods: Data from 20 patients with unilateral posterior crossbite were selected retrospectively from the Orthodontics Department of the University of Genoa and the Department of Biomedical Surgical and Dental Sciences of the University of Milan, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico Milan. Inclusion criteria were set as skeletal class I; adult patients (age > 18); good general health; patients with a transverse maxillary deficiency with unilateral posterior crossbite and maxillary constriction ≥ 5 mm; Superficial electromyographic (EMG) examinations at T0 and T1. Exclusion criteria were smoking, metabolic bone diseases (e.g., hyperparathyroidism, vitamin C deficiency), chronic use of corticoids before or during treatment, parafunctional habits (e.g., bruxism), and temporomandibular joint dysfunction. The Shapiro−Wilk test was performed to check whether the data were normally distributed. Differences for each variable before and after SARME were analyzed with a paired t-test (p < 0.05). Results: The statistical analysis demonstrated no statistically significant differences between the EMG values taken before and after SARME regarding the standardized electrical activity of the masticatory muscles (masseter and anterior temporalis (p > 0.05)). Conclusions: Considering the specific conditions of this study, it can be concluded that SARME did not alter the EMG activity of the masseter and temporal muscles. The present study has shown that the masticatory musculature evaluated after approximately 8 months of therapy can adapt well to SARME.

7.
Biomedicines ; 10(10)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36289798

RESUMO

The materials available today allow for extensive oral rehabilitations in a non-invasive way, and often an orthodontic preparation is useful and, thanks to the use of clear aligners, is predictable and comfortable. A preliminary study of the wax-up, mock-up, and set-up allow the clinician to plan every aspect of the treatment in detail. Furthermore, the procedure offers the patient an intuitive and understandable view of the expected final result. The new proposed method, called "speed up therapy", allows for the integration of the orthodontic set-up with the mock-up technique, simulating the occlusal and aesthetic components of the planned restoration, in all details. The clinical case presented, demonstrates step by step the predictability and clinical reliability of the proposed procedure. The final clinical result coincides exactly with the initial mock-up and demonstrates that the proposed method is predictable and reliable. The correct execution of the technique is rigorously customized, and its success is operator dependent, both for the clinical aspects and for the dental laboratory. Thus, the visualization of the objectives of the treatment constitutes a decisive support for the clinician and provides the patient with the possibility of benefiting from an immediate improvement by making it easier for them to accept a treatment plan. The visualization also includes an orthodontic phase that potentially lengthens the treatment but makes the realization more conservative and predictable.

8.
J Contemp Dent Pract ; 23(11): 1085-1090, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37073930

RESUMO

AIM: The aim of this in vitro study is to assess the color stability of different esthetic veneer restorative materials (feldspathic ceramic, hybrid ceramic, zirconia-reinforced lithium silicate glass ceramic, and composite resin) after being exposed to commonly consumed beverages that have staining potential. MATERIALS AND METHODS: Sixty specimens were prepared into rectangular blocks with fixed dimensions of 10 × 12 × 2.5 mm. Machinable feldspathic ceramic (FC), zirconia-reinforced lithium silicate glass ceramic (LS), and a hybrid ceramic (HC) were milled using CAD/CAM (n = 15), and specimens of microparticle composite resin (MPC) were manually prepared by with the same dimensions (n = 15). All specimens were randomly divided into three subgroups (= 5) according to immersing solutions used (coffee, black tea, and red wine). All specimens were immersed for a period of 72 hours. A colorimetric evaluation was done for each specimen before and after immersion using a spectrophotometer and the difference in color was calculated according to the CIE-Lab system. To analyze the data, two-way ANOVA and one-way ANOVA tests of significance were used to compare between the different study groups, followed by pairwise comparisons using post hoc test (Tukey). RESULTS: Different restorative materials showed statistical significance regarding color change after staining (p < 0.001); however, no statistical significance in color change (p > 0.05) was found between the different beverages used. CONCLUSION: All tested ceramic materials had better color stability compared with composite resin. All the staining beverages used in the current study might cause a significant color change in the tested restorative materials. CLINICAL SIGNIFICANCE: The color stability of esthetic restorative materials affects their clinical performance in the oral cavity, where the restorative materials are usually exposed to staining beverages that are frequently consumed by patients. Therefore, it is important to understand the staining effect of the different beverages on esthetic restorative materials.


Assuntos
Porcelana Dentária , Lítio , Humanos , Bebidas , Cerâmica , Cor , Resinas Compostas , Desenho Assistido por Computador , Materiais Dentários , Estética Dentária , Teste de Materiais , Propriedades de Superfície
9.
J Contemp Dent Pract ; 22(8): 856-859, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34753835

RESUMO

AIM AND OBJECTIVE: The objective of this study was to monitor the pH stability over a period of 6 months of two-bottle self-etching (SE) primers. MATERIALS AND METHODS: Four commercially available two-bottle SE primer solutions, Adhese SE (Ivoclar Vivadent; Schaan, Liechtenstein), Clearfil SE (Kuraray; Tokyo, Japan), Contax Primer (DMG; Hamburg, Germany), and Enabond SE (Micerium; Avegno (Ge), Italy), containing water as the main solvent were selected. The pH values during a 6-month storage period at intermittent temperature were daily measured by means of a microprocessor-based pH/temperature meter and hence recorded, tabulated, and analyzed. RESULTS: The mean values of overall pH measurements and standard deviation for Adhese SE, Clearfil SE, Contax Primer, and Enabond SE are, respectively, 1.70 (±0.01), 1.72 (±0.01), 1.20 (±0.01), 1.80 (±0.01). One-way ANOVA did not detect any significant change of the mean pH values of all measurements over time. CONCLUSION: The conventional 6-months storage did not affect the pH values of the water-containing primers of two-bottle SE adhesives. CLINICAL SIGNIFICANCE: This study provides evidence that conventional storage under adequate conditions did not affect the pH values of the water-containing primers of two-bottle SE adhesives with different monomer formulations. Clinicians may rely on the known pH value of the selected SE adhesive during shelf-life.


Assuntos
Colagem Dentária , Cimentos de Resina , Condicionamento Ácido do Dente , Análise do Estresse Dentário , Dentina , Adesivos Dentinários , Concentração de Íons de Hidrogênio , Teste de Materiais , Resistência ao Cisalhamento , Água
10.
J Clin Med ; 10(21)2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34768483

RESUMO

(1) Background. Dental implant placement in the anterior region requires extreme precision due to relatively high aesthetic demand. This narrative review aimed to analyse some of the available clinical studies of the socket-shield technique and determine its viability for dental implant survival/success and complication rates. (2) Methods. An electronic search for publications was performed using the Cochrane, PubMed-MEDLINE, Web of Science, and Google Scholar databases. All electronic searches included human clinical and animal studies and were performed by three independent examiners. (3) Results. A total of 1383 records were identified with the initial search strategies, but only 25 full texts + five abstracts clinical studies were kept after the recruitment criteria screening. The technical details, advantages, and limitations of the techniques were illustrated. (4) Conclusion. Within the limitations of the present review, it would be merely justified that immediate dental implant placement in conjunction with the socket-shield technique can be a promising strategy for dental implant therapy.

11.
J Clin Exp Dent ; 13(8): e835-e844, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34512924

RESUMO

BACKGROUND: Marginal seal of a nanohybrid bulk-fill composite compared to a nanohybrid conventional composite, using a universal adhesive (UA) applied in etch-and-rinse (ER) and self-etch (SE) mode was investigated. MATERIAL AND METHODS: Thirty-six intact molars were selected and two standardized cavities in each tooth were prepared and allocated into four groups according to restorative material and etching strategy. All samples were placed in a 1% methylene blue solution for 24 h, then cut in the middle of the restorations obtaining two parts (n=144) and used for microscopic evaluation (50x) for dye penetration measurements. RESULTS: The data were analysed by ANOVA and Tukey post-hoc test (p<0.05). Marginal seal was influenced by adhesive strategy (p<0.05) but not from the composite used (p>0.05). CONCLUSIONS: Simplified restorations with nanohybrid bulk-fill composite showed comparable marginal leakage to incrementally placed nanohybrid composite. The UA used with a ER technique resulted in better marginal seal irrespective of the restorative material used. Key words:Bulk-fill composite, universal adhesive, self-etching, etch-and-rinse, marginal seal.

12.
J Contemp Dent Pract ; 22(5): 568-571, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34318779

RESUMO

AIM: To present the healing, development, and long-term clinical results after a combined gingival-bone graft as an alternative treatment for the management of critical extraction sites in the esthetic zone. BACKGROUND: To enhance the knowledge of in vivo soft and hard tissue remodeling, in this case report, we observed the healing, development, and long-term clinical results after a case of a combined gingival-bone graft as an alternative treatment for the management of critical extraction sites. CASE DESCRIPTION: Autogenous grafts of gingival and bone tissue were placed in a 56-year-old female patient, where a hopeless upper left central incisor with an evident loss of both the buccal and the palatal bony plates and with endodontic problems was due for extraction. In order to obtain enough autogenous tissue for filling the defect, a cylindrical free gingival and bone graft was retrieved from the retromolar area with a trephine drill, to obtain hard and soft tissues for grafting the postextraction defect. After 6 months, following soft tissue maturation and once esthetic and natural gingival contours were achieved, the surgical site was prosthetically restored with a porcelain fused to a metal bridge and scheduled for regular follow-up. CONCLUSION: No complications were observed either from the donor site or from the recipient site. The post-treatment result was esthetically pleasing, based upon successful architectural stability of both hard and soft tissues. Although more studies are needed to confirm the beneficial use of this approach, the procedure can be considered a viable option in the management of soft and hard tissue remodeling in esthetically compromised cases. CLINICAL SIGNIFICANCE: The gingival-bone graft may be considered as an alternative treatment for the management of critical extraction sites in the esthetic area. How to cite this article: Signore A, Stepanov M, Angelis ND, et al. Free Gingival-Bone Graft in the Anterior Maxilla: A Clinical Case Report. J Contemp Dent Pract 2021;22(5):568-571.


Assuntos
Estética Dentária , Maxila , Transplante Ósseo , Implantação Dentária Endóssea , Feminino , Humanos , Maxila/cirurgia , Pessoa de Meia-Idade , Extração Dentária , Alvéolo Dental/cirurgia
13.
Int J Mol Sci ; 22(9)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-33919443

RESUMO

BACKGROUND: Injury of the trigeminal nerve in oral and maxillofacial surgery can occur. Schwann cell mitochondria are regulators in the development, maintenance and regeneration of peripheral nerve axons. Evidence shows that after the nerve injury, mitochondrial bioenergetic dysfunction occurs and is associated with pain, neuropathy and nerve regeneration deficit. A challenge for research is to individuate new therapies able to normalise mitochondrial and energetic metabolism to aid nerve recovery after damage. Photobiomodulation therapy can be an interesting candidate, because it is a technique involving cell manipulation through the photonic energy of a non-ionising light source (visible and NIR light), which produces a nonthermal therapeutic effect on the stressed tissue. METHODS: The review was based on the following questions: (1) Can photo-biomodulation by red and NIR light affect mitochondrial bioenergetics? (2) Can photobiomodulation support damage to the trigeminal nerve branches? (preclinical and clinical studies), and, if yes, (3) What is the best photobiomodulatory therapy for the recovery of the trigeminal nerve branches? The papers were searched using the PubMed, Scopus and Cochrane databases. This review followed the ARRIVE-2.0, PRISMA and Cochrane RoB-2 guidelines. RESULTS AND CONCLUSIONS: The reliability of photobiomodulatory event strongly bases on biological and physical-chemical evidence. Its principal player is the mitochondrion, whether its cytochromes are directly involved as a photoacceptor or indirectly through a vibrational and energetic variation of bound water: water as the photoacceptor. The 808-nm and 100 J/cm2 (0.07 W; 2.5 W/cm2; pulsed 50 Hz; 27 J per point; 80 s) on rats and 800-nm and 0.2 W/cm2 (0.2 W; 12 J/cm2; 12 J per point; 60 s, CW) on humans resulted as trustworthy therapies, which could be supported by extensive studies.


Assuntos
Metabolismo Energético , Terapia com Luz de Baixa Intensidade/métodos , Mitocôndrias/efeitos da radiação , Regeneração Nervosa , Recuperação de Função Fisiológica , Traumatismos do Nervo Trigêmeo/radioterapia , Animais , Humanos , Traumatismos do Nervo Trigêmeo/patologia
14.
Int J Prosthodont ; 34(3): 324­333, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33616557

RESUMO

PURPOSE: To assess the short-term outcomes of two different conservative preparation designs for posterior zirconia inlay-retained fixed dental prostheses (IRFDPs) and to analyze the marginal integrity of such restorations. MATERIALS AND METHODS: Thirty patients with a missing maxillary first molar participated in this study and were divided randomly into two groups: one that received abutment preparations for inlay retainers (ID group, n = 20), including a proximal box and an occlusal extension, and one that received only proximal box preparations (PB group, n = 10). Zirconia IRFDPs were bonded in position and followed up after 2 weeks, 6 months, 1 year, and then annually. The in situ restorations were duplicated utilizing a single-step putty/wash impression technique at the 2-week and 2-year follow-up visits. Restoration margins were evaluated under scanning electron microscopy, and marginal continuity was calculated as a percentage of the whole margin at the tooth-cement (TC) interface and the zirconia-cement (ZC) interface. RESULTS: After a mean observation period of 26.2 months, all restorations were still in function. The only complication encountered was debonding of restorations; however, they were re-bonded back in place without issue. The cumulative Kaplan-Meier 2-year survival rate for the IRFDPs was 86.6%. There was a significant difference between the two groups regarding percentage of continuous margins (P < .05) after 2 years, with the percentage of continuous margins in the ID group at 92.8% and 91.5% at the TC and ZC interfaces, respectively, and in the PB group at 84.1% and 78.6% at the TC and ZC interfaces, respectively. CONCLUSION: Zirconia-based monolithic IRFDPs can be recommended for short-term replacement of a single maxillary molar.


Assuntos
Prótese Parcial Fixa , Restaurações Intracoronárias , Porcelana Dentária , Falha de Restauração Dentária , Humanos , Zircônio
15.
J Contemp Dent Pract ; 22(9): 979-984, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35000939

RESUMO

AIM: The carrier-based obturation is a reliable technique for sealing the endodontic space. The GuttaCore with a pink internal core of cross-linked gutta-percha, named GuttaCore Pink, has been recently introduced into the market. The aim of this in vitro study was to compare the quality of the apical seal of two-carrier-based system, Soft Core and the GuttaCore Pink, through the measurement of apical dye leakage. MATERIALS AND METHODS: Eighty-six extracted human teeth with single canals were used. Samples were shaped using ProTaper Universal rotary files up to a #30 apical size and randomly divided into four groups. Group SC (n = 40) was obturated with #30 Soft Core Obturators; Group GCP (n = 40) was obturated with #30 GuttaCore Pink obturators; Group CT+ (n = 3) and CT- (n = 3) left nonobturated used as positive and negative controls, respectively. The samples underwent a process of passive/active dye penetration and after a clearing procedure. The extent of the dye was measured under stereomicroscope. RESULTS: The Mann-Whitney U test showed a statistically significant difference (p <0.05) between Soft Core and GuttaCore Pink in terms of apical dye leakage, both considering the mean and the maximum infiltration value with a greater infiltration rate for Soft Core. CONCLUSION: In vitro GuttaCore Pink showed less apical dye leakage than Soft Core. CLINICAL SIGNIFICANCE: The apical leakage of carrier-based obturation materials, observed in both GuttaCore Pink and Soft Core, may be considered material-dependent.


Assuntos
Infiltração Dentária , Materiais Restauradores do Canal Radicular , Guta-Percha , Humanos , Obturação do Canal Radicular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...