Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Hemodial Int ; 22(2): 270-278, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28643378

RESUMO

INTRODUCTION: High ultrafiltration (UF) rates can result in intradialytic hypotension and are associated with increased mortality. The effects of a weight-based UF rate limit on intradialytic hypotension and the potential for unwanted fluid weight gain and hospitalizations for volume overload are unknown. METHODS: This retrospective cohort study examined 123 in-center hemodialysis patients at one facility who transitioned to 13 mL/kg/h maximum UF rates. Patients were studied for an 8 week UF rate limit exposure period and compared to the 8-week period immediately prior, during which the cohort served as its own historical control. The primary outcomes were frequency of intradialytic hypotension events and percentage of treatments with a hypotension event. FINDINGS: The delivered UF rate was lower during the exposure compared to the baseline period (mean UF rate 7.90 ± 4.45 mL/kg/h vs. 8.92 ± 5.64 mL/kg/h; P = 0.0005). The risk of intradialytic hypotension was decreased during the exposure compared to baseline period (event rate per treatment 0.0569 vs. 0.0719, OR 0.78 [95% CI 0.62-1.00]; P = 0.0474), as was the risk of having a treatment with a hypotension event (percentage of treatments with event 5.2% vs. 6.8%, OR 0.75 [95% CI 0.58-0.96]; P = 0.0217). Subgroup analyses demonstrated that these findings were attributable to patients with high baseline UF rates. Statistically significant differences in all-cause or volume overload-related hospitalization were not observed during the exposure period. DISCUSSION: A weight-based UF rate limit of 13 mL/kg/h was associated with a decrease in the rate of intradialytic hypotension events among in-center hemodialysis patients.


Assuntos
Hipotensão/fisiopatologia , Diálise Renal/métodos , Ultrafiltração/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Clin J Am Soc Nephrol ; 6(7): 1635-43, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21597024

RESUMO

BACKGROUND AND OBJECTIVES: Relative to hemoglobin (Hb) A(1c), glycated albumin (GA) more accurately reflects glycemic control in patients with diabetes mellitus and ESRD. We determined the association between GA, HbA(1c), and glucose levels with survival and hospitalizations in diabetic dialysis patients. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Quarterly GA levels were measured for up to 2.33 years in 444 prevalent patients with diabetes and ESRD. Proportional hazard time-dependent covariate models were computed with adjustment for demographic characteristics, comorbidities, and laboratory variables. Similar analyses were performed for available HbA(1c) and monthly random serum glucose determinations. RESULTS: The participants were 53% male, 54% African American, 43% Caucasian, 90% on hemodialysis, with a mean (SD) age of 62 (12) years and median follow-up duration of 2.25 years. GA and HbA(1c) mean ± SD 21.5% ± 6.0%, median 20.4% and mean ± SD 6.9% ± 6.6%, median 1.6%, respectively. There were 156 deaths during the observation period. In best-fit models, predictors of death included increasing GA, increasing age, presence of peripheral vascular disease, decreasing serum albumin, and decreasing hemoglobin concentrations. HbA(1c) and random serum glucose concentrations were not predictive of survival. Increasing GA levels were associated with hospitalization in the 17 days after measurement, whereas HbA(1c) was not. CONCLUSIONS: In contrast to the HbA(1c) and random serum glucose values, GA accurately predicts the risk of death and hospitalizations in patients with diabetes mellitus and ESRD. The GA assay should be considered by clinicians who care for patients with diabetes on dialysis.


Assuntos
Nefropatias Diabéticas/sangue , Nefropatias Diabéticas/terapia , Hospitalização/estatística & dados numéricos , Falência Renal Crônica/sangue , Falência Renal Crônica/terapia , Diálise Renal/mortalidade , Albumina Sérica/metabolismo , Negro ou Afro-Americano/estatística & dados numéricos , Idoso , Biomarcadores/sangue , Glicemia/metabolismo , Distribuição de Qui-Quadrado , Nefropatias Diabéticas/etnologia , Nefropatias Diabéticas/mortalidade , Feminino , Hemoglobinas Glicadas/metabolismo , Produtos Finais de Glicação Avançada , Humanos , Falência Renal Crônica/etnologia , Falência Renal Crônica/mortalidade , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , North Carolina/epidemiologia , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , População Branca/estatística & dados numéricos , Albumina Sérica Glicada
3.
Eur J Echocardiogr ; 5(3): 231-6, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15147667

RESUMO

Two-dimensional echocardiography is a valuable tool in visualizing and monitoring aortic valve and root abnormalities. We present a rare case of a patient with massive aortic regurgitation due to cusp aneurysm, which was accurately diagnosed by echocardiography and treated by valve replacement. A complicated course with recurrent aneurysms of the aortic wall after aortic valve replacement was remarkable in this case. Although different possible etiologies could not be determined, endocarditis and/or aortitis may be the most likely explanation of the complicated and finally fatal course of this patient.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Aneurisma Aórtico/complicações , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia , Evolução Fatal , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Pessoa de Meia-Idade , Recidiva
4.
Pediatr Allergy Immunol ; 14(4): 266-71, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12911503

RESUMO

Levels of exhaled nitric oxide (eNO) are flow-dependent, and the choice of an optimal flow rate for off-line and on-line eNO measurement has raised much debate. Recently, a flow rate of 50 ml/s was recommended, but children younger than 5-6 years are not capable of stabilizing their expiratory flow at low flow rates. The power of off-line eNO values to discriminate between normal and atopic children was therefore evaluated at different exhalation flow rates. At flow rates of both 8.3 ml/s and of 350 ml/s, children (8-12 years) sensitive to house dust mite have two-fold higher eNO values (p < 0.001) as compared with children lacking such a sensitivity. The power of eNO to discriminate between normal and atopic subjects was similar at the two flow rates (no difference in AUC of receiver operation curves, p = 0.89). All children from 4.5 to 5 years of age (n = 29) could perform a single off-line exhalation manoeuvre at high (>350 ml/s) but not at low (8.3 ml/s) flow rates. At high exhalation flow rate, eNO was 7.1 +/- 2.4 (mean +/- SD) median, 6.5 p.p.b. with a mean variation coefficient of 5.5%. Depending on their developmental level, about half of the younger children (35-46 months of age) could perform an off-line exhalation manoeuvre at high flow rate with good reproducibility (mean variation coefficient of 6.6%). It is concluded that an exhalation flow rate of 350 ml/s is feasible to determine off-line eNO-values in children from 3.5 years of age, and that this high flow rate does not compromise the power of eNO to detect allergic disease.


Assuntos
Expiração/fisiologia , Fluxo Expiratório Forçado/fisiologia , Óxido Nítrico/metabolismo , Adulto , Fatores Etários , Área Sob a Curva , Criança , Proteção da Criança , Pré-Escolar , Feminino , Humanos , Hipersensibilidade Imediata/metabolismo , Hipersensibilidade Imediata/fisiopatologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Ensaios Clínicos Controlados Aleatórios como Assunto , Reprodutibilidade dos Testes
5.
Cancer Nurs ; 24(6): 436-45, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11762506

RESUMO

This study aims to discover (1) how relatives adjust to their new life situations following the death of a patient with cancer in hospice and (2) how those relatives have been supported by healthcare professionals both before and after the patient's death. The data were collected with a structured questionnaire administered to relatives of patients with cancer who died in a Finnish hospice in 1998 and 1999. The questionnaires were administered by the hospice staff to all family members who met the criteria specified (n = 589). The final sample comprised 258 family members, most of whom were the deceased patients' spouses. The Mann-Whitney U-test and the Kruskal-Wallis test were used to analyze the data. Instrument reliability was ascertained by the Cronbach alpha coefficient. The relatives had little difficulty accepting their new life situation and adjusting to their new role. The main factors affecting adjustment were being the patient's spouse and the age of both patient and relative. Relatives believed that they received a moderate amount of support from healthcare professionals, both before and after the patient's death. Most of the information they received concerned the patient's illness and treatment and daily condition. Communication was honest and based upon the relatives' needs. Emotional support before the patient's death consisted mainly of accepting the relative and listening to what relatives had to say.


Assuntos
Adaptação Psicológica , Luto , Família/psicologia , Neoplasias , Relações Profissional-Família , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Finlândia , Hospitais para Doentes Terminais , Humanos , Masculino , Pessoa de Meia-Idade , Apoio Social , Estatísticas não Paramétricas
6.
Int J Cardiol ; 44(3): 285-7, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8077075

RESUMO

Two hours after taking 100 mg of flecainide, a patient developed gastrointestinal complaints, dizziness and shortness of breath. The ECG demonstrated novel prolonged JT interval with negative T wave in the precordial leads. During admission, several attacks of non-sustained ventricular tachycardia occurred. The plasma drug concentration was 814 mg/l. Although the tachycardia was non-sustained, cardiovascular collapse developed. Serum electrolytes were normal and myocardial infarction was excluded. The patient is now free of symptoms without medications.


Assuntos
Fibrilação Atrial/terapia , Flecainida/efeitos adversos , Sistema de Condução Cardíaco/efeitos dos fármacos , Taquicardia Ventricular/induzido quimicamente , Idoso , Fibrilação Atrial/tratamento farmacológico , Cardioversão Elétrica , Eletrocardiografia , Feminino , Flecainida/uso terapêutico , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...