Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 305: 123561, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37866258

RESUMO

Examining intact kidney stones both qualitatively and quantitatively can be difficult due to their size and fragility. Many modern analysis methods often lead to the destruction of the stone's structure during sample preparation. Preserving the structural integrity is crucial for accurately determining the chemical distribution of the components of kidney stones, which, in turn, improves our understanding of the disease's etiology. Infrared microspectroscopy and imaging play a vital role in revealing the stone's microstructure and component distribution. Consequently, this research focuses on investigating the impact of different sample preparation techniques on kidney stone analysis using infrared microspectroscopy. Specifically, it explores how polishing the surface of cross-sectioned stones influences the results. The polishing was performed utilizing abrasive discs and lapping films. A polishing device was also designed for the optimization of sample preparation. Additionally, this work involved a comparison of reflection infrared imaging with Attenuated Total Internal Reflection (ATR) infrared microspectroscopic imaging for the analysis of the microstructure of urinary stones.


Assuntos
Cálculos Renais , Humanos
2.
Diagnostics (Basel) ; 13(23)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38066814

RESUMO

As the number of coronary computed tomography angiography (CTA) examinations is expected to increase, technologies to optimize the imaging workflow are of great interest. The aim of this study was to investigate the potential of artificial intelligence (AI) to improve clinical workflow and diagnostic accuracy in high-volume cardiac imaging centers. A total of 120 patients (79 men; 62.4 (55.0-72.7) years; 26.7 (24.9-30.3) kg/m2) undergoing coronary CTA were randomly assigned to a standard or an AI-based (human AI) coronary analysis group. Severity of coronary artery disease was graded according to CAD-RADS. Initial reports were reviewed and changes were classified. Both groups were similar with regard to age, sex, body mass index, heart rate, Agatston score, and CAD-RADS. The time for coronary CTA assessment (142.5 (106.5-215.0) s vs. 195.0 (146.0-265.5) s; p < 0.002) and the total reporting time (274.0 (208.0-377.0) s vs. 350 (264.0-445.5) s; p < 0.02) were lower in the human AI than in the standard group. The number of cases with no, minor, or CAD-RADS relevant changes did not differ significantly between groups (52, 7, 1 vs. 50, 8, 2; p = 0.80). AI-based analysis significantly improves clinical workflow, even in a specialized high-volume setting, by reducing CTA analysis and overall reporting time without compromising diagnostic accuracy.

3.
J Biol Chem ; 299(8): 104935, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37331601

RESUMO

Connexin mutant mice develop cataracts containing calcium precipitates. To test whether pathologic mineralization is a general mechanism contributing to the disease, we characterized the lenses from a nonconnexin mutant mouse cataract model. By cosegregation of the phenotype with a satellite marker and genomic sequencing, we identified the mutant as a 5-bp duplication in the γC-crystallin gene (Crygcdup). Homozygous mice developed severe cataracts early, and heterozygous animals developed small cataracts later in life. Immunoblotting studies showed that the mutant lenses contained decreased levels of crystallins, connexin46, and connexin50 but increased levels of resident proteins of the nucleus, endoplasmic reticulum, and mitochondria. The reductions in fiber cell connexins were associated with a scarcity of gap junction punctae as detected by immunofluorescence and significant reductions in gap junction-mediated coupling between fiber cells in Crygcdup lenses. Particles that stained with the calcium deposit dye, Alizarin red, were abundant in the insoluble fraction from homozygous lenses but nearly absent in wild-type and heterozygous lens preparations. Whole-mount homozygous lenses were stained with Alizarin red in the cataract region. Mineralized material with a regional distribution similar to the cataract was detected in homozygous lenses (but not wild-type lenses) by micro-computed tomography. Attenuated total internal reflection Fourier-transform infrared microspectroscopy identified the mineral as apatite. These results are consistent with previous findings that loss of lens fiber cell gap junctional coupling leads to the formation of calcium precipitates. They also support the hypothesis that pathologic mineralization contributes to the formation of cataracts of different etiologies.


Assuntos
Catarata , Cristalinas , Minerais , Animais , Camundongos , Cálcio/metabolismo , Catarata/genética , Catarata/fisiopatologia , Conexinas/genética , Conexinas/metabolismo , Cristalinas/genética , Cristalinas/metabolismo , Cristalino/patologia , Minerais/metabolismo , Microtomografia por Raio-X , Modelos Animais de Doenças
4.
Eur J Radiol Open ; 10: 100481, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36852255

RESUMO

Purpose: The combined testing for coronary artery and pulmonary diseases is of clinical interest as risk factors are shared. In this study, a novel ECG-gated tin-filtered ultra-low dose chest CT protocol (GCCT) for integrated heart and lung acquisition and the applicability of artificial intelligence (AI)-based coronary artery calcium scoring were assessed. Methods: In a clinical registry of 10481 patients undergoing heart and lung CT, GCCT was applied in 44 patients on a dual-source CT. Coronary calcium scans (CCS) with 120 kVp, 100 kVp, and tin-filtered 100 kVp (Sn100) of controls, matched with regard to age, sex, and body-mass index, were retrieved from the registry (ntotal=176, 66.5 (59.4-74.0) years, 52 men). Automatic tube current modulation was used in all scans. In 20 patients undergoing GCCT and Sn100 CCS, Agatston scores were measured both semi-automatically by experts and by AI, and classified into six groups (0, <10, <100, <400, <1000, ≥1000). Results: Effective dose decreased significantly from 120 kVp CCS (0.50 (0.41-0.61) mSv) to 100 kVp CCS (0.34 (0.26-0.37) mSv) to Sn100 CCS (0.14 (0.11-0.17) mSv). GCCT showed higher values (0.28 (0.21-0.32) mSv) than Sn100 CCS but lower than 120 kVp and 100 kVp CCS (all p < 0.05) despite greater scan length. Agatston scores correlated strongly between GCCT and Sn100 CCS in semi-automatic and AI-based measurements (both ρ = 0.98, p < 0.001) resulting in high agreement in Agatston score classification (κ = 0.97, 95% CI 0.92-1.00; κ = 0.89, 95% CI 0.79-0.99). Regarding chest findings, further diagnostic steps were recommended in 28 patients. Conclusions: GCCT allows for reliable coronary artery disease and lung cancer screening with ultra-low radiation exposure. GCCT-derived Agatston score shows excellent agreement with standard CCS, resulting in equivalent risk stratification.

5.
Front Cell Dev Biol ; 10: 951231, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35938173

RESUMO

Cataracts are lens opacities that are among the most common causes of blindness. It is commonly believed that cataracts develop through the accumulation of damage to lens proteins. However, recent evidence suggests that cataracts can result from calcium ion accumulation and the precipitation of calcium-containing salts. To test for the presence of precipitates and to identify their components, we studied the lenses of mice that develop cataracts due to mutations of connexin46 and connexin50. Micro-computed tomography showed the presence of radio-dense mineral in the mutant lenses, but not in wild-type lenses. Three-dimensional reconstructions of the scans showed that the distribution of the radio-dense mineral closely paralleled the location and morphology of the cataracts. The mutant lens homogenates also contained insoluble particles that stained with Alizarin red (a dye that stains Ca2+ deposits). Using attenuated total internal reflection micro-Fourier transform infrared spectroscopy, we identified the mineral as calcium phosphate in the form of apatite. Taken together, these data support the novel paradigm that cataracts are formed through pathological mineralization within the lens.

6.
BMJ Open ; 12(8): e058304, 2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35940836

RESUMO

OBJECTIVES: Since the safety of coronary CT angiography (CTA) is of great importance, especially with regard to widening indications and increasing morbidity, the aim of this study was to assess influencing factors. METHODS: Patients undergoing coronary CTA in a third-generation dual-source CT in a radiological centre were included in a clinical registry. Up to 20 mg metoprolol was administered intravenously to attain a heart rate ≤65/min. Glyceryl trinitrate (GTN) was administered in doses of 0.8 mg and 0.4 mg. Blood pressure was measured before the administration and after the CTA. RESULTS: Out of 5500 consecutive patients (3194 men, 62.3 (54.9-70.0) years), adverse events occurred in 68 patients (1.2%) with mild anaphylactoid reactions (0.4%), vasovagal symptoms (0.3%) and extravasation (0.3%) being most frequent. Anti-allergic drugs were given in 17 patients, atropine in 3 patients and volume in 1 patient. Drug administration resulted in a significant mean arterial pressure decline (96.0 (88.3-106.0) vs 108.7 (99.7-117.3) mmHg; p<0.001). Patients who suffered systolic blood pressure drops >20 mmHg or >40 mmHg were older (66.5 (58.6-73.3) vs 60.5 (53.6-68.3) years; 70.2 (63.3-76.5) vs 62.1 (54.7-69.6) years), more often male (65.1% vs 54.4%; 68.9% vs 57.3%) and had higher Agatston score equivalents (83.0 (2.0-432.0) vs 15.0 (0.0-172.0); 163.0 (16.3-830.8) vs 25.0 (0.0-220.0); all p<0.001). GTN dose reduction lowered the fraction of patients suffering from blood pressure drops >20 mmHg or >40 mmHg from 34.5% to 27.4% and from 6.1% to 3.5% (both p<0.001), respectively. The proportion of coronary segments with impaired image quality did not differ significantly. CONCLUSIONS: Coronary CTA with intravenous beta-blocker administration is a safe procedure in an outpatient setting as adverse events are rare and mostly mild. Reduced GTN doses can further improve safety by lowering the rate of significant blood pressure drops, which occurred especially in elderly men with increased plaque burden. TRIAL REGISTRATION NUMBER: NCT03815123.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Idoso , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Masculino , Nitroglicerina/efeitos adversos , Pacientes Ambulatoriais , Sistema de Registros , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
7.
BMC Cardiovasc Disord ; 22(1): 34, 2022 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-35120459

RESUMO

BACKGROUND: Machine-Learning Computed Tomography-Based Fractional Flow Reserve (CT-FFRML) is a novel tool for the assessment of hemodynamic relevance of coronary artery stenoses. We examined the diagnostic performance of CT-FFRML compared to stress perfusion cardiovascular magnetic resonance (CMR) and tested if there is an additional value of CT-FFRML over coronary computed tomography angiography (cCTA). METHODS: Our retrospective analysis included 269 vessels in 141 patients (mean age 67 ± 9 years, 78% males) who underwent clinically indicated cCTA and subsequent stress perfusion CMR within a period of 2 months. CT-FFRML values were calculated from standard cCTA. RESULTS: CT-FFRML revealed no hemodynamic significance in 79% of the patients having ≥ 50% stenosis in cCTA. Chi2 values for the statistical relationship between CT-FFRML and stress perfusion CMR was significant (p < 0.0001). CT-FFRML and cCTA (≥ 70% stenosis) provided a per patient sensitivity of 88% (95%CI 64-99%) and 59% (95%CI 33-82%); specificity of 90% (95%CI 84-95%) and 85% (95%CI 78-91%); positive predictive value of 56% (95%CI 42-69%) and 36% (95%CI 24-50%); negative predictive value of 98% (95%CI 94-100%) and 94% (95%CI 90-96%); accuracy of 90% (95%CI 84-94%) and 82% (95%CI 75-88%) when compared to stress perfusion CMR. The accuracy of cCTA (≥ 50% stenosis) was 19% (95%CI 13-27%). The AUCs were 0.89 for CT-FFRML and 0.74 for cCTA (≥ 70% stenosis) and therefore significantly different (p < 0.05). CONCLUSION: CT-FFRML compared to stress perfusion CMR as the reference standard shows high diagnostic power in the identification of patients with hemodynamically significant coronary artery stenosis. This could support the role of cCTA as gatekeeper for further downstream testing and may reduce the number of patients undergoing unnecessary invasive workup.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Aprendizado de Máquina , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Idoso , Vasos Coronários/fisiopatologia , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Estudos Retrospectivos
8.
Front Cardiovasc Med ; 8: 691665, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434975

RESUMO

Background: Coronary artery disease (CAD) shows a chronic but heterogeneous clinical course. Coronary CT angiography (CTA) allows for the visualization of the entire coronary tree and the detection of early stages of CAD. The aim of this study was to assess short-time changes in non-calcified and mixed plaques and their clinical impact using coronary CTA in a real-world setting. Methods: Between 11/2014 and 07/2019, 6,701 patients had a coronary CTA with a third-generation dual-source CT, of whom 77 patients (57 males, 63.8 ± 10.8 years) with a chronic CAD received clinically indicated follow-up CTA. Non-calcified and mixed plaques were analyzed in 1,211 coronary segments. Patients were divided into groups: stable, progressive, or regressive plaques. Results: Within the follow-up period of 22.3 ± 10.4 months, 44 patients (58%) showed stable plaques, 27 (36%) showed progression, 5 (7%) showed regression. One patient was excluded due to an undetermined CAD course showing both, progressive and regressive plaques. Age did not differ significantly between groups. Patients with plaque regression were predominantly female (80 vs. 20%), whereas patients showing progression were mainly male (85 vs. 15%; p < 0.01 for both). Regression was only observed in patients with mild CAD or one-vessel disease. The follow-up CTA led to changes in patient management in the majority of subjects (n = 50; 66%). Conclusions: Changes in coronary artery plaques can be observed within a short period resulting in an adjustment of the clinical management in the majority of CAD patients. Follow-up coronary CTA renders the non-invasive assessment of plaque development possible and allows for an individualized diagnostics and therapy optimization.

9.
Urolithiasis ; 49(2): 123-135, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33026465

RESUMO

Kidney stones frequently develop as an overgrowth on Randall's plaque (RP) which is formed in the papillary interstitium. The organic composition of RP is distinct from stone matrix in that RP contains fibrillar collagen; RP in tissue has also been shown to have two proteins that are also found in stones, but otherwise the molecular constituents of RP are unstudied. We hypothesized that RP contains unique organic molecules that can be differentiated from the stone overgrowth by fluorescence. To test this, we used micro-CT-guided polishing to expose the interior of kidney stones for multimodal imaging with multiphoton, confocal and infrared microscopy. We detected a blue autofluorescence signature unique to RP, the specificity of which was also confirmed in papillary tissue from patients with stone disease. High-resolution mineral mapping of the stone also showed a transition from the apatite within RP to the calcium oxalate in the overgrowth, demonstrating the molecular and spatial transition from the tissue to the urine. This work provides a systematic and practical approach to uncover specific fluorescence signatures which correlate with mineral type, verifies previous observations regarding mineral overgrowth onto RP and identifies a novel autofluorescence signature of RP demonstrating RP's unique molecular composition.


Assuntos
Apatitas/análise , Oxalato de Cálcio/análise , Cálculos Renais/química , Medula Renal/patologia , Imagem Óptica/métodos , Biópsia , Feminino , Humanos , Cálculos Renais/cirurgia , Medula Renal/química , Medula Renal/diagnóstico por imagem , Masculino , Microscopia Confocal/métodos , Imagem Multimodal/métodos , Nefrolitotomia Percutânea , Espectroscopia de Infravermelho com Transformada de Fourier , Ureteroscopia , Microtomografia por Raio-X/métodos
10.
J Clin Invest ; 130(4): 1948-1960, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32149733

RESUMO

The major risk factor for kidney stone disease is idiopathic hypercalciuria. Recent evidence implicates a role for defective calcium reabsorption in the renal proximal tubule. We hypothesized that claudin-2, a paracellular cation channel protein, mediates proximal tubule calcium reabsorption. We found that claudin-2-null mice have hypercalciuria due to a primary defect in renal tubule calcium transport and papillary nephrocalcinosis that resembles the intratubular plugs in kidney stone formers. Our findings suggest that a proximal tubule defect in calcium reabsorption predisposes to papillary calcification, providing support for the vas washdown hypothesis. Claudin-2-null mice were also found to have increased net intestinal calcium absorption, but reduced paracellular calcium permeability in the colon, suggesting that this was due to reduced intestinal calcium secretion. Common genetic variants in the claudin-2 gene were associated with decreased tissue expression of claudin-2 and increased risk of kidney stones in 2 large population-based studies. Finally, we describe a family in which males with a rare missense variant in claudin-2 have marked hypercalciuria and kidney stone disease. Our findings indicate that claudin-2 is a key regulator of calcium excretion and a potential target for therapies to prevent kidney stones.


Assuntos
Claudinas , Regulação da Expressão Gênica , Variação Genética , Hipercalciúria , Cálculos Renais , Túbulos Renais Proximais , Animais , Cálcio/urina , Claudinas/deficiência , Claudinas/metabolismo , Hipercalciúria/genética , Hipercalciúria/patologia , Hipercalciúria/urina , Cálculos Renais/genética , Cálculos Renais/patologia , Cálculos Renais/urina , Túbulos Renais Proximais/metabolismo , Túbulos Renais Proximais/patologia , Camundongos , Camundongos Knockout
11.
J Endourol ; 34(3): 385-393, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31880949

RESUMO

Objectives: To describe the papillary pathology found in uric acid (UA) stone formers, and to investigate the mineral form of tissue deposits. Materials and Methods: We studied eight UA stone formers treated with percutaneous nephrolithotomy. Papillae were imaged intraoperatively using digital endoscopy, and cortical and papillary biopsies were taken. Biopsies were analyzed by light microscopy, micro-CT, and microinfrared spectroscopy. Results: As expected, urine pH was generally low. UA supersaturation exceeded one in all but one case, compatible with the stone material. By intraoperative imaging, the renal papillae displayed a heterogeneous mixture of plaque and plugging, ranging from normal to severe. All patients had mineral in ducts of Bellini and inner medullary collecting ducts, mainly apatite with lesser amounts of urate and/or calcium oxalate in some specimens. Papillary and cortical interstitial tissue injury was modest despite the tubule plugging. No instance was found of a stone growing attached to either plaque or plugs. Conclusions: UA stone formers resemble those with ileostomy in having rather low urine pH while forming tubule plugs that contain crystals that can only form at pH values above those of their bulk urine. This discrepancy between tissue mineral deposits and stone type suggests that local tubular pH exceeds that of the bulk urine, perhaps because of localized tubule injury. The manner in which UA stones form and the discordance between tubule crystals and stone type remain open research questions.


Assuntos
Cálculos Renais/cirurgia , Ácido Úrico/química , Adulto , Idoso , Biópsia , Feminino , Humanos , Cálculos Renais/patologia , Masculino , Pessoa de Meia-Idade , Nefrolitotomia Percutânea
12.
J Org Chem ; 85(2): 682-690, 2020 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-31834799

RESUMO

The design of dissipative systems, which operate out-of-equilibrium by consuming chemical fuels, is challenging. As yet, there are a few examples of privileged fuel chemistries that can be broadly applied in abiotic systems in the same way that ATP hydrolysis is exploited throughout biochemistry. The key issue is that designing nonequilibrium systems is inherently about balancing the relative rates of coupled reactions. The use of carbodiimides as fuels to generate transient aqueous carboxylic anhydrides has recently been used in examples of new nonequilibrium materials and supramolecular assemblies. Here, we explore the kinetics of formation and decomposition of a series of benzoic anhydrides generated from the corresponding acids and EDC under typical conditions (EDC = N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride). The reactions can be described by a simple mechanism that merges known behavior for the two processes independently. Structure-property effects in these systems are dominated by differences in the anhydride decomposition rate. The kinetic parameters allow trends in concentration-dependent properties to be simulated, such as reaction lifetimes, peak anhydride concentrations, and yields. For key properties, there are diminishing returns with the addition of increasing amounts of fuel. These results should provide useful guidelines for the design of functional systems making use of this chemistry.

13.
Clin Res Cardiol ; 106(7): 485-492, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28168514

RESUMO

BACKGROUND: The usage of coronary CT angiography (CTA) is appropriate in patients with acute or chronic chest pain; however the diagnostic accuracy may be challenged with increased Agatston score (AS), increased heart rate, arrhythmia and severe obesity. Thus, we aim to determine the potential of the recently introduced third-generation dual-source CT (DSCT) for CTA in a 'real-life' clinical setting. METHODS: Two hundred and sixty-eight consecutive patients (age: 67 ± 10 years; BMI: 27 ± 5 kg/m²; 61% male) undergoing clinically indicated CTA with DSCT were included in the retrospective single-center analysis. A contrast-enhanced volume dataset was acquired in sequential (SSM) (n = 151) or helical scan mode (HSM) (n = 117). Coronary segments were classified in diagnostic or non-diagnostic image quality. A subset underwent invasive angiography to determine the diagnostic accuracy of CTA. RESULTS: SSM (96.8 ± 6%) and HSM (97.5 ± 8%) provided no significant differences in the overall diagnostic image quality. However, AS had significant influence on diagnostic image quality exclusively in SSM (B = 0.003; p = 0.0001), but not in HSM. Diagnostic image quality significantly decreased in SSM in patients with AS ≥2,000 (p = 0.03). SSM (sensitivity: 93.9%; specificity: 96.7%; PPV: 88.6%; NPV: 98.3%) and HSM (sensitivity: 97.4%; specificity: 94.3%; PPV: 86.0%; NPV: 99.0%) provided comparable diagnostic accuracy (p = n.s.). SSM yielded significantly lower radiation doses as compared to HSM (2.1 ± 2.0 vs. 5.1 ± 3.3 mSv; p = 0.0001) in age and BMI-matched cohorts. CONCLUSION: SSM in third-generation DSCT enables significant dose savings and provides robust diagnostic image quality in patients with AS ≤2000 independent of heart rate, heart rhythm or obesity.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos
14.
Microsc Microanal ; 22(3): 649-55, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27068491

RESUMO

An effective method for detecting and characterizing counterfeit finished dosage forms and packaging materials is described in this study. Using attenuated total internal reflection Fourier transform infrared spectroscopic imaging, suspect tablet coating and core formulations as well as multi-layered foil safety seals, bottle labels, and cigarette tear tapes were analyzed and compared directly with those of a stored authentic product. The approach was effective for obtaining molecular information from structures as small as 6 µm.

15.
Microsc Microanal ; 21(3): 626-36, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25980473

RESUMO

Until recently, the analysis of polymer laminates using infrared microspectroscopy involved the painstaking separation of individual layers by dissection or by obtaining micrometer thin cross-sections. The latter usually requires the expertise of an individual trained in microtomy and even then, the very structure of the laminate could affect the outcome of the spectral results. The recent development of attenuated total internal reflection (ATR) infrared microspectroscopy imaging has provided a new avenue for the analysis of these multilayer structures. This report compares ATR infrared microspectroscopy imaging with conventional transmission infrared microspectroscopy imaging. The results demonstrate that the ATR method offers improved spatial resolution, eliminates a variety of competing optical processes, and requires minimal sample preparation relative to transmission measurements. These advantages were illustrated using a polymer laminate consisting of 11 different layers whose thickness ranged in size from 4-20 µm. The spatial resolution achieved by using an ATR-FTIR (Fourier transform infrared spectroscopy) imaging technique was diffraction limited. Contrast in the ATR images was enhanced by principal component analysis.

16.
Appl Spectrosc ; 69(2): 230-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25587997

RESUMO

Two methods commonly employed for molecular surface analysis and thin-film analysis of microscopic areas are attenuated total reflection infrared (ATR-IR) microspectroscopy and confocal Raman microspectroscopy. In the former method, the depth of the evanescent probe beam can be controlled by the wavelength of light, the angle of incidence, or the refractive index of the internal reflection element. Because the penetration depth is proportional to the wavelength of light, one could interrogate a smaller film thickness by moving from the mid-infrared region to the visible region employing Raman spectroscopy. The investigation of ATR Raman microspectroscopy, a largely unexplored technique available to Raman microspectroscopy, was carried out. A Renishaw inVia Raman microscope was externally modified and used in conjunction with a solid immersion lens (SIL) to perform ATR Raman experiments. Thin-film polymer samples were analyzed to explore the theoretical sampling depth for experiments conducted without the SIL, with the SIL, and with the SIL using evanescent excitation. The feasibility of micro-ATR Raman was examined by collecting ATR spectra from films whose thickness measured from 200 to 60 nm. Films of these thicknesses were present on a much thicker substrate, and features from the underlying substrate did not become visible until the thin film reached a thickness of 68 nm.


Assuntos
Polímeros/análise , Análise Espectral Raman/métodos , Desenho de Equipamento , Lasers , Cimento de Policarboxilato/química , Polímeros/química , Reprodutibilidade dos Testes , Compostos de Selênio/química , Razão Sinal-Ruído , Análise Espectral Raman/instrumentação , Compostos de Zinco/química
17.
Anat Rec (Hoboken) ; 298(5): 865-77, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25615853

RESUMO

Medullary sponge kidney (MSK) is associated with recurrent stone formation, but the clinical phenotype is unclear because patients with other disorders may be incorrectly labeled MSK. We studied 12 patients with histologic findings pathognomonic of MSK. All patients had an endoscopically recognizable pattern of papillary malformation, which may be segmental or diffuse. Affected papillae are enlarged and billowy, due to markedly enlarged inner medullary collecting ducts (IMCD), which contain small, mobile ductal stones. Patients had frequent dilation of Bellini ducts, with occasional mineral plugs. Stones may form over white (Randall's) plaque, but most renal pelvic stones are not attached, and have a similar morphology as ductal stones, which are a mixture of calcium oxalate and apatite. Patients had no abnormalities of urinary acidification or acid excretion; the most frequent metabolic abnormality was idiopathic hypercalciuria. Although both Runx2 and Osterix are expressed in papillae of MSK patients, no mineral deposition was seen at the sites of gene expression, arguing against a role of these genes in this process. Similar studies in idiopathic calcium stone formers showed no expression of these genes at sites of Randall's plaque. The most likely mechanism for stone formation in MSK appears to be crystallization due to urinary stasis in dilated IMCD with subsequent passage of ductal stones into the renal pelvis where they may serve as nuclei for stone formation.


Assuntos
Cálculos Renais/patologia , Rim em Esponja Medular/patologia , Osteogênese/fisiologia , Adulto , Idoso , Biópsia , Oxalato de Cálcio/metabolismo , Feminino , Humanos , Cálculos Renais/metabolismo , Masculino , Rim em Esponja Medular/metabolismo , Pessoa de Meia-Idade
18.
Anat Rec (Hoboken) ; 297(4): 731-48, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24478243

RESUMO

Our previous work has shown that stone formers who form calcium phosphate (CaP) stones that contain any brushite (BRSF) have a distinctive renal histopathology and surgical anatomy when compared with idiopathic calcium oxalate stone formers (ICSF). Here we report on another group of idiopathic CaP stone formers, those forming stone containing primarily hydroxyapatite, in order to clarify in what ways their pathology differs from BRSF and ICSF. Eleven hydroxyapatite stone formers (HASF) (2 males, 9 females) were studied using intra-operative digital photography and biopsy of papillary and cortical regions to measure tissue changes associated with stone formation. Our main finding is that HASF and BRSF differ significantly from each other and that both differ greatly from ICSF. Both BRSF and ICSF patients have significant levels of Randall's plaque compared with HASF. Intra-tubular deposit number is greater in HASF than BRSF and nonexistent in ICSF while deposit size is smaller in HASF than BRSF. Cortical pathology is distinctly greater in BRSF than HASF. Four attached stones were observed in HASF, three in 25 BRSF and 5-10 per ICSF patient. HASF and BRSF differ clinically in that both have higher average urine pH, supersaturation of CaP, and calcium excretion than ICSF. Our work suggests that HASF and BRSF are two distinct and separate diseases and both differ greatly from ICSF.


Assuntos
Oxalato de Cálcio/metabolismo , Fosfatos de Cálcio/metabolismo , Durapatita/metabolismo , Cálculos Renais/patologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Cálculos Renais/metabolismo , Masculino , Microscopia Eletrônica de Transmissão , Pessoa de Meia-Idade , Microtomografia por Raio-X , Adulto Jovem
19.
Appl Spectrosc ; 67(11): 1252-63, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24160876

RESUMO

Advances in fiber optic materials have allowed for the construction of fibers and waveguides capable of transmitting infrared radiation. An investigation of the transmission characteristics associated with two commonly used types of infrared-transmitting fibers/waveguides for prospective use in a fiber/waveguide-coupled attenuated total internal reflection (ATR) probe was performed. Characterization of silver halide polycrystalline fiber optics and hollow silica waveguides was done on the basis of the transmission of infrared light using a conventional fiber optic coupling accessory and an infrared microscope. Using the fiber optic coupling accessory, the average percent transmission for three silver halide fibers was 18.1 ± 6.1% relative to a benchtop reflection accessory. The average transmission for two hollow waveguides (HWGs) using the coupling accessory was 8.0 ± 0.3%. (Uncertainties in the relative percent transmission represent the standard deviations.) Reduced transmission observed for the HWGs was attributed to the high numerical aperture of the coupling accessory. Characterization of the fibers/waveguides using a zinc selenide lens objective on an infrared microscope indicated 24.1 ± 7.2% of the initial light input into the silver halide fibers was transmitted. Percent transmission obtained for the HWGs was 98.7 ± 0.1%. Increased transmission using the HWGs resulted from the absence or minimization of insertion and scattering losses due to the hollow air core and a better-matched numerical aperture. The effect of bending on the transmission characteristics of the fibers/waveguides was also investigated. Significant deviations in the transmission of infrared light by the solid-core silver halide fibers were observed for various bending angles. Percent transmission greater than 98% was consistently observed for the HWGs at the bending angles. The combined benefits of high percent transmission, reproducible instrument responses, and increased bending tolerance indicated HWGs should be preferred in the construction of a fiber/waveguide-coupled ATR probe.

20.
Appl Spectrosc ; 66(3): 304-11, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22449308

RESUMO

Several prism-based spectrographs employing a mercury cadmium telluride (MCT) focal plane array detector have been interfaced to an infrared microscope. In the combined system, the area-defining aperture of the microscope also served as the entrance slit to the spectrograph. This investigation considered the fundamental limits of diffraction for both the spectrograph and microscope in order to determine both the spatial and spectral resolution of the system as a whole. Experimental results for spectral resolution, spectral range, and peak-to-peak noise have been presented. Finally, the dynamic capabilities of one spectrograph/microscope combination were investigated.


Assuntos
Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos , Compostos de Cádmio/química , Fluoreto de Cálcio/química , Compostos de Mercúrio/química , Polímeros/química , Cloreto de Sódio/química , Xilenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...