1.
IEEE Int Conf Robot Autom ; 2023: 4724-4731, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125032

RESUMO

In the last decade, various robotic platforms have been introduced that could support delicate retinal surgeries. Concurrently, to provide semantic understanding of the surgical area, recent advances have enabled microscope-integrated intraoperative Optical Coherent Tomography (iOCT) with high-resolution 3D imaging at near video rate. The combination of robotics and semantic understanding enables task autonomy in robotic retinal surgery, such as for subretinal injection. This procedure requires precise needle insertion for best treatment outcomes. However, merging robotic systems with iOCT introduces new challenges. These include, but are not limited to high demands on data processing rates and dynamic registration of these systems during the procedure. In this work, we propose a framework for autonomous robotic navigation for subretinal injection, based on intelligent real-time processing of iOCT volumes. Our method consists of an instrument pose estimation method, an online registration between the robotic and the iOCT system, and trajectory planning tailored for navigation to an injection target. We also introduce intelligent virtual B-scans, a volume slicing approach for rapid instrument pose estimation, which is enabled by Convolutional Neural Networks (CNNs). Our experiments on ex-vivo porcine eyes demonstrate the precision and repeatability of the method. Finally, we discuss identified challenges in this work and suggest potential solutions to further the development of such systems.

2.
J Imaging ; 8(11)2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36354875

RESUMO

Correct positioning of the endoscope is crucial for successful hip arthroscopy. Only with adequate alignment can the anatomical target area be visualized and the procedure be successfully performed. Conventionally, surgeons rely on anatomical landmarks such as bone structure, and on intraoperative X-ray imaging, to correctly place the surgical trocar and insert the endoscope to gain access to the surgical site. One factor complicating the placement is deformable soft tissue, as it can obscure important anatomical landmarks. In addition, the commonly used endoscopes with an angled camera complicate hand-eye coordination and, thus, navigation to the target area. Adjusting for an incorrectly positioned endoscope prolongs surgery time, requires a further incision and increases the radiation exposure as well as the risk of infection. In this work, we propose an augmented reality system to support endoscope placement during arthroscopy. Our method comprises the augmentation of a tracked endoscope with a virtual augmented frustum to indicate the reachable working volume. This is further combined with an in situ visualization of the patient anatomy to improve perception of the target area. For this purpose, we highlight the anatomy that is visible in the endoscopic camera frustum and use an automatic colorization method to improve spatial perception. Our system was implemented and visualized on a head-mounted display. The results of our user study indicate the benefit of the proposed system compared to baseline positioning without additional support, such as an increased alignment speed, improved positioning error and reduced mental effort. The proposed approach might aid in the positioning of an angled endoscope, and may result in better access to the surgical area, reduced surgery time, less patient trauma, and less X-ray exposure during surgery.

3.
IEEE Int Conf Robot Autom ; 2022: 7717-7723, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-36128019

RESUMO

Retinal surgery is a complex medical procedure that requires exceptional expertise and dexterity. For this purpose, several robotic platforms are currently under development to enable or improve the outcome of microsurgical tasks. Since the control of such robots is often designed for navigation inside the eye in proximity to the retina, successful trocar docking and insertion of the instrument into the eye represents an additional cognitive effort, and is therefore one of the open challenges in robotic retinal surgery. For this purpose, we present a platform for autonomous trocar docking that combines computer vision and a robotic setup. Inspired by the Cuban Colibri (hummingbird) aligning its beak to a flower using only vision, we mount a camera onto the endeffector of a robotic system. By estimating the position and pose of the trocar, the robot is able to autonomously align and navigate the instrument towards the Trocar Entry Point (TEP) and finally perform the insertion. Our experiments show that the proposed method is able to accurately estimate the position and pose of the trocar and achieve repeatable autonomous docking. The aim of this work is to reduce the complexity of the robotic setup prior to the surgical task and therefore, increase the intuitiveness of the system integration into clinical workflow.

4.
Biomed Opt Express ; 13(4): 2414-2430, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35519277

RESUMO

The development and integration of intraoperative optical coherence tomography (iOCT) into modern operating rooms has motivated novel procedures directed at improving the outcome of ophthalmic surgeries. Although computer-assisted algorithms could further advance such interventions, the limited availability and accessibility of iOCT systems constrains the generation of dedicated data sets. This paper introduces a novel framework combining a virtual setup and deep learning algorithms to generate synthetic iOCT data in a simulated environment. The virtual setup reproduces the geometry of retinal layers extracted from real data and allows the integration of virtual microsurgical instrument models. Our scene rendering approach extracts information from the environment and considers iOCT typical imaging artifacts to generate cross-sectional label maps, which in turn are used to synthesize iOCT B-scans via a generative adversarial network. In our experiments we investigate the similarity between real and synthetic images, show the relevance of using the generated data for image-guided interventions and demonstrate the potential of 3D iOCT data synthesis.

5.
Sensors (Basel) ; 22(3)2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35161880

RESUMO

Optical coherence tomography (OCT) is a medical imaging modality that is commonly used to diagnose retinal diseases. In recent years, linear and radial scanning patterns have been proposed to acquire three-dimensional OCT data. These patterns show differences in A-scan acquisition density across the generated volumes, and thus differ in their suitability for the diagnosis of retinal diseases. While radial OCT volumes exhibit a higher A-scan sampling rate around the scan center, linear scans contain more information in the peripheral scan areas. In this paper, we propose a method to combine a linearly and radially acquired OCT volume to generate a single compound volume, which merges the advantages of both scanning patterns to increase the information that can be gained from the three-dimensional OCT data. We initially generate 3D point clouds of the linearly and radially acquired OCT volumes and use an Iterative Closest Point (ICP) variant to register both volumes. After registration, the compound volume is created by selectively exploiting linear and radial scanning data, depending on the A-scan density of the individual scans. Fusing regions from both volumes with respect to their local A-scan sampling density, we achieve improved overall anatomical OCT information in a high-resolution compound volume. We demonstrate our method on linear and radial OCT volumes for the visualization and analysis of macular holes and the surrounding anatomical structures.


Assuntos
Perfurações Retinianas , Tomografia de Coerência Óptica , Humanos
6.
J Imaging ; 9(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36662102

RESUMO

Three decades after the first set of work on Medical Augmented Reality (MAR) was presented to the international community, and ten years after the deployment of the first MAR solutions into operating rooms, its exact definition, basic components, systematic design, and validation still lack a detailed discussion. This paper defines the basic components of any Augmented Reality (AR) solution and extends them to exemplary Medical Augmented Reality Systems (MARS). We use some of the original MARS applications developed at the Chair for Computer Aided Medical Procedures and deployed into medical schools for teaching anatomy and into operating rooms for telemedicine and surgical guidance throughout the last decades to identify the corresponding basic components. In this regard, the paper is not discussing all past or existing solutions but only aims at defining the principle components and discussing the particular domain modeling for MAR and its design-development-validation process, and providing exemplary cases through the past in-house developments of such solutions.

7.
Biomed Opt Express ; 12(2): 1085-1104, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33680560

RESUMO

The emergence of robotics could enable ophthalmic microsurgical procedures that were previously not feasible due to the precision limits of manual delivery, for example, targeted subretinal injection. Determining the distance between the needle tip, the internal limiting membrane (ILM), and the retinal pigment epithelium (RPE) both precisely and reproducibly is required for safe and successful robotic retinal interventions. Recent advances in intraoperative optical coherence tomography (iOCT) have opened the path for 4D image-guided surgery by providing near video-rate imaging with micron-level resolution to visualize retinal structures, surgical instruments, and tool-tissue interactions. In this work, we present a novel pipeline to precisely estimate the distance between the injection needle and the surface boundaries of two retinal layers, the ILM and the RPE, from iOCT volumes. To achieve high computational efficiency, we reduce the analysis to the relevant area around the needle tip. We employ a convolutional neural network (CNN) to segment the tool surface, as well as the retinal layer boundaries from selected iOCT B-scans within this tip area. This results in the generation and processing of 3D surface point clouds for the tool, ILM and RPE from the B-scan segmentation maps, which in turn allows the estimation of the minimum distance between the resulting tool and layer point clouds. The proposed method is evaluated on iOCT volumes from ex-vivo porcine eyes and achieves an average error of 9.24 µm and 8.61 µm measuring the distance from the needle tip to the ILM and the RPE, respectively. The results demonstrate that this approach is robust to the high levels of noise present in iOCT B-scans and is suitable for the interventional use case by providing distance feedback at an average update rate of 15.66 Hz.

8.
Med Image Comput Comput Assist Interv ; 12265: 267-276, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34085059

RESUMO

Intraoperative Optical Coherence Tomography (iOCT) has advanced in recent years to provide real-time high resolution volumetric imaging for ophthalmic surgery. It enables real-time 3D feedback during precise surgical maneuvers. Intraoperative 4D OCT generally exhibits lower signal-to-noise ratio compared to diagnostic OCT and visualization is complicated by instrument shadows occluding retinal tissue. Additional constraints of processing data rates upwards of 6GB/s create unique challenges for advanced visualization of 4D OCT. Prior approaches for real-time 4D iOCT rendering have been limited to applying simple denoising filters and colorization to improve visualization. We present a novel real-time rendering pipeline that provides enhanced intraoperative visualization and is specifically designed for the high data rates of 4D iOCT. We decompose the volume into a static part consisting of the retinal tissue and a dynamic part including the instrument. Aligning the static parts over time allows temporal compounding of these structures for improved image quality. We employ a translational motion model and use axial projection images to reduce the dimensionality of the alignment. A model-based instrument segmentation on the projections discriminates static from dynamic parts and is used to exclude instruments from the compounding. Our real-time rendering method combines the compounded static information with the latest iOCT data to provide a visualization which compensates instrument shadows and improves instrument visibility. We evaluate the individual parts of our pipeline on pre-recorded OCT volumes and demonstrate the effectiveness of our method on a recorded volume sequence with a moving retinal forceps.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...