Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Environ Manage ; 357: 120851, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38581894

RESUMO

Conventional liquid treatments for large-scale, low-level radioactive wastewater, such as ion exchange and waste solidification, face challenges due to the large amounts of secondary waste and high disposal costs. A new large-scale decontamination method is proposed that uses kapok fiber composites for rapid radionuclide adsorption and high volume reduction to minimize secondary waste. The composite consists of natural zeolite and kapok holocellulose, which has high water-soaking ability and low-temperature pyrolysis. The kapok composites, fabricated using a commercial wet-laid nonwoven manufacturing process, absorbs 99% of low-level radioactive cesium in 20 min, reducing the volume by 98% and the weight by 47% at 300 °C. The low-temperature pyrolysis process below 300 °C prevents cesium desorption and gasification by avoiding zeolite destruction. The mass-producible kapok composites can be used for adsorbing various radionuclides in large-scale wastewater by attaching specific adsorbents for target isotopes to the composites.


Assuntos
Resíduos Radioativos , Zeolitas , Águas Residuárias , Césio , Radioisótopos , Adsorção , Resíduos Radioativos/prevenção & controle
3.
Acta Biomater ; 178: 137-146, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38447810

RESUMO

Endoscopic biliary stent insertion has been widely used for the treatment of benign biliary stricture (BBS). Thus, the development of stent materials in the perspectives of structure, mechanical properties, and biocompatibility has been also studied. However, conventional metal and plastic stents have several disadvantages, such as repeated procedures to remove or exchange them, dislodgment, restenosis, biocompatibility, and poor mechanical properties. Sustainable effectiveness, attenuation and prevention of fibrosis, and biocompatibility are key factors for the clinical application of stents to BBS treatment. In addition, loading drugs could show synergistic effects with stents' own performance. We developed a dexamethasone-eluting biodegradable stent (DBS) consisting of a sheath/core structure with outstanding mechanical properties and sustained release of dexamethasone, which maintained its functions in a BBS duct over 12 weeks in a swine model. The insertion of our DBS not only expanded BBS areas but also healed secondary ulcers as a result of the attenuation of fibrosis. After 16 weeks from the insertion, BBS areas were totally improved, and the DBS was degraded and thoroughly disappeared without re-intervention for stent removal. Our DBS would be an effective clinical tool for non-vascular diseases. STATEMENT OF SIGNIFICANCE: This study describes the insertion of a drug-eluting biodegradable stent (DBS) into the bile duct. The sheath/core structure of DBS confers substantial durability and a sustained drug release profile. Drug released from the DBS exhibited anti-fibrotic effects without inflammatory responses in both in vitro and in vivo experiments. The DBS maintained its function over 12 weeks after insertion into the common bile duct, expanding benign biliary stricture (BBS) and reducing inflammation to heal secondary ulcers in a swine BBS model. After 16 weeks from the DBS insertion, the DBS thoroughly disappeared without re-intervention for stent removal, resulting in totally improved BBS areas. Our findings not only spotlight the understanding of the sheath/core structure of the biodegradable stent, but also pave the way for the further application for non-vascular diseases.


Assuntos
Colestase , Úlcera , Animais , Suínos , Constrição Patológica , Stents , Colestase/terapia , Fibrose , Dexametasona/farmacologia
4.
Ann Surg Treat Res ; 102(2): 90-99, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35198512

RESUMO

PURPOSE: The current drain tubes for preventing surgically biliary anastomotic stricture are not naturally and easily removed. If a drain tube using biodegradable material is easily available and the degradation time of the tube is well controlled, surgical anastomotic stricture and fibrosis could be prevented. The aim of this animal study was to evaluate the preventive effect of novel biodegradable stents (BS) on biliary stricture and fibrosis after duct-to-duct (DD) biliary anastomosis. METHODS: Ten mini-pigs were allocated to the control group (n = 5) and or the stent group (n = 5). The common bile duct was exposed through surgical laparotomy and then resected transversely. In the stent group, a 4-mm or 6-mm polydioxanone/magnesium sheath-core BS was inserted according to the width of the bile duct, followed by DD biliary anastomosis. In the control group, DD biliary anastomosis was performed without BS insertion. RESULTS: In the stent group, stents were observed without deformity for up to 4 weeks in all animals. Eight weeks later, histopathologic examination revealed that the common bile duct of the anastomosis site was relatively narrower in circumference in the control group compared to the stent group. The degree of fibrosis in the control group was more marked than in the stent group (3.84 mm vs. 0.68 mm, respectively; P < 0.05). CONCLUSION: Our study showed that novel BS maintained their original shape and radial force for an adequate time and then disappeared without adverse events. The BS could prevent postoperative complications and strictures after DD biliary anastomosis.

5.
Sci Rep ; 11(1): 22418, 2021 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-34789784

RESUMO

Lead, which has been used for radiation shielding in medicine, is currently sought to be replaced by an eco-friendly shielding material. Therefore, it should be replaced with shielding materials possessing excellent processability and radiation shielding performance similar to that of lead. In this study, a new process technology was developed focusing on the processability of tungsten, a representative eco-friendly shielding material. It is difficult to reproduce the shielding performance when using the method of coating nonwoven fabrics with a liquid using tungsten powder on a polymer material, which is adopted to ensure the flexibility of the shielding fabric. To address this, tungsten powder was sprayed on the fabric using a plasma thermal spray coating process and coated to a thickness of 0.2 mm to evaluate the shielding performance. Compared to standard lead with a thickness of 0.2 mm, the shielding efficiency differed by approximately 15%. Since the developed process can maintain the amount of injection in an area, it is possible to ensure the reproducibility of the shielding performance and automated process for mass production. This approach is economically feasible as it does not entail the mixing of polymer materials; hence, it can be used for preparing radiation shielding clothing for medical institutions.

6.
Materials (Basel) ; 14(5)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802544

RESUMO

This study investigates the potential of propolis-embedded zeolite nanocomposites for dental implant application. Propolis-embedded zeolite nanocomposites were fabricated by complexation of propolis and zeolites. Then, they were pelleted with Poly(L-lactide) (PLA)/poly(ε-caprolactone) (PCL) polymer for the fabrication of a dental implant. The chemical properties of propolis were not changed during the fabrication of propolis-embedded zeolite nanocomposites in attenuated total reflection-fourier transform infra-red (ATR FT-IR) spectroscopy measurements. Propolis was continuously released from propolis-embedded zeolite nanocomposites over one month. PLA/PCL pellets containing propolis-embedded zeolite nanocomposites showed longer sustained release behavior compared to propolis-embedded zeolite nanocomposites. Propolis-embedded zeolite nanocomposite powder showed similar antibacterial activity against C. albicans in an agar plate and formed an inhibition zone as well as chlorohexidine (CHX) powder. Eluted propolis solution from PLA/PCL pellets also maintained antibacterial activity as well as CHX solution. Furthermore, eluted propolis solution from PLA/PCL pellets showed significant antibacterial efficacy against C. albicans, S. mutans and S. sobrinus. Dental implants fabricated from PLA/PCl polymer and propolis-embedded zeolite nanocomposites also have antibacterial efficacy and negligible cytotoxicity against normal cells. We suggest that PLA/PCl pellets containing propolis-embedded zeolite nanocomposites are promising candidates for dental implants.

7.
Sci Rep ; 11(1): 3676, 2021 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-33574471

RESUMO

Natural and medical radiation are the most frequent sources of daily low-dose radiation exposure for the general public, but these radiation levels are generally acceptable. Among various occupations, aviation crew members and medical workers are exposed to high levels of radiation from scattered rays. This study focused on developing clothing for shielding aviation crew members from natural radiation during air travel. Materials were selected considering their radiation-shielding properties. A tungsten double-layered composite yarn and a polyethylene terephthalate (PET) fiber fabric containing BaSO4 were manufactured. The characteristics and shielding performances of the products were analyzed. Prototypes of a protective scarf (for shielding the thyroid gland) and apron (for shielding the torso) for flight attendants were produced. A lightweight fabric was produced that neither restricts the movement of the wearer nor causes them skin discomfort. The shielding performances of the tungsten composite and PET fiber fabrics containing BaSO4 were 0.018 mmPb and 0.03 mmPb, respectively, demonstrating low-dose shielding that may be useful for protecting aviation crew members from scattered rays. The characteristics of the developed fibers are comparable to those of materials used in clothing production; therefore, low-dose radiation-shielding clothing could be manufactured for use in aviation, medical, and other industries.

8.
Dig Endosc ; 33(7): 1158-1169, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33319399

RESUMO

OBJECTIVES: The clinical outcomes and prevalence of adverse events associated with biliary biodegradable stents (BS) can differ according to degradation process and time. The aim of this study was to observe the degradation process and time of different BS prototypes, and to evaluate sequential changes in their mechanical properties. METHODS: Using an in vitro bile flow phantom model, we compared degradation time, radial force changes, and morphologic changes among four different BS prototypes: polydioxanone (PDO) BS, polyglycolide (PGA) BS, polydioxanone/poly-l-lactic acid (PDO/PLLA) sheath-core BS, and polydioxaone/magnesium (PDO/Mg) sheath-core BS. Using an in vivo swine bile duct dilation model, we performed a direct peroral cholangioscopy (DPOC) examination to observe the biodegradation process and related adverse events at regular intervals. RESULTS: In the bile flow phantom model, the PGA BS and PDO/Mg BS prototypes showed rapid radial force reduction and morphological changes and complete degradation within six weeks. PDO/PLLA BS maintained high radial force and kept their original shape for longer than the PDO BS, up to 16 weeks. A total of 24 BS were inserted into the dilated bile ducts of 12 swine. In this animal model, DPOC examination revealed that PDO BS and PDO/PLLA BS maintained their original shapes for approximately 12 weeks, but PDO BS showed a greater degree of fragmentation and induced biliary stones and bile duct obstruction. CONCLUSION: Our results showed that PDO/PLLA BS maintained their original shape and radial force for a relatively long time and minimized adverse events.


Assuntos
Procedimentos Cirúrgicos do Sistema Biliar , Colestase , Animais , Ductos Biliares/cirurgia , Colangiopancreatografia Retrógrada Endoscópica , Colestase/etiologia , Colestase/cirurgia , Dilatação , Stents , Suínos
9.
J Nanosci Nanotechnol ; 20(7): 4529-4532, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31968513

RESUMO

A new effective oxidative solution for titanium (Ti) surface etching was recently developed. The present in vitro study was aimed at determining the influence of shorter (than 240 min) treatment time on the surface characteristics of the Ti nano/micro hierarchical structures. Cylinder-shaped Ti grade 5 alloys were etched for 30, 60, 120, and 240 min at room temperature and cleaned successively with acetone, ethanol, and distilled water in an ultrasonic bath. The micro- and nanostructures, surface roughness, dynamic wettability, and the surface elemental composition of the etched surfaces were evaluated. Nano/micro hierarchical structures, composed of micro-pits and nano-channels, were formed on the Ti surface through simple immersion in the oxidative solution. The findings suggest that the 120-min immersion yielded significant enhancement in the roughness and wettability of the Ti surfaces.

10.
J Nanosci Nanotechnol ; 19(2): 1044-1047, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30360197

RESUMO

Recently, a simple surface modification treatment of titanium (Ti) was developed to produce nano-and micro-scale features on the surfaces via simple immersion in an oxidative aqueous solution (30% hydrogen peroxide/5% sodium bicarbonate). However, this treatment method of Ti surfaces requires a relatively long immersion time (4 h) in the oxidative solution. In this study, we investigated whether an increase in the temperature of the oxidative etching solution can shorten the immersion time of Ti effectively. Polished grade 5 dental Ti (Ti-6Al-4V) discs were immersed in the oxidative aqueous solution either for 30 or 60 min. The temperature of the etching solution was maintained at 25 (similar to room temperature), 35, or 45 °C during etching. The etched surfaces were studied in terms of micro- and nano-structures, surface roughness, and wettability (surface energy). The increase in the temperature of the solution accelerated the etching effect of Ti and created both micro- and nano-structures on the surfaces more effectively. In particular, immersion for 60 min at the solution temperature of 35 °C significantly increased the surface roughness and wettability, although the etching effect was enhanced further at the solution temperature of 45 °C.

11.
J Nanosci Nanotechnol ; 18(2): 848-852, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29448504

RESUMO

In this in vitro study, nystatin-alginate microparticles were successfully fabricated to control the release of nystatin from a commercial dental tissue conditioner. These nystatin-alginate microparticles were spherical and had a slightly rough surface. The microparticles incorporated into the tissue conditioner were distributed homogeneously throughout the tissue conditioner matrix. The incorporation of the microparticles did not deteriorate the mechanical properties of the original material. The agar diffusion test results showed that the tissue conditioner containing the microparticles had a good antifungal effect against Candida albicans. The nystatin-alginate microparticles efficiently controlled the release of nystatin from the tissue conditioner matrix over the experimental period of 14 days. Moreover, the nystatin-alginate microparticles incorporated in the tissue conditioner showed effective antifungal function even at lower concentrations of nystatin. The current study suggests that the tissue conditioner containing the nystatin-alginate microparticle carrier system has potential as an effective antifungal material.


Assuntos
Alginatos/farmacologia , Antifúngicos/farmacologia , Nistatina/farmacologia , Condicionamento de Tecido Mole Oral , Candida albicans/efeitos dos fármacos , Reembasadores de Dentadura , Ácido Glucurônico/farmacologia , Ácidos Hexurônicos/farmacologia
12.
J Nanosci Nanotechnol ; 18(2): 1308-1311, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29448579

RESUMO

Self-assembled monolayers of thiols have been used to link a range of materials to planar gold surfaces or gold nanoparticles in nanoscience and nanotechnology. Novel mercapto silane systems are a promising alternative to dental noble metal alloys for enhanced resin bonding durability Goldbased alloys for full-cast restorations contain various base metal elements, which may bond to acidic functional monomers chemically, in addition to noble metal elements. This study examined how the additional incorporation of a phosphate monomer (di-2-hydroxyethyl methacryl hydrogenphosphate, DHP) into novel mercapto silane primer systems affected the resin bond strength to a type IV gold alloy pretreated with the primers. One of three commercial primers (Alloy Primer and M. L. Primer) and three experimental primer systems ((1) blend of γ-mercaptopropyltrimethoxysilane (SPS) and γ-methacryloxypropyltrimethoxysilane (MPS) (both 1.0 wt%), (2) 1.0 wt% DHP-containing primer, and (3) blend of SPS, MPS, and DHP (each 1.0 wt%)) was applied to the alloy surfaces after sandblasting. Resin cylinders (diameter: 2.38 mm) were bonded to the surfaces and light-cured. All bonded specimens were stored in water at 37 °C for 24 h and then half of them additionally water immersed for 7 days (37 °C) and thermocycled 10,000 times before the shear bond strength test (n = 10). The mercapto silane systems (SPS + MPS) were found to show superior resin bonding durability to the commercial primers and the only DHP-containing primer, regardless of additional incorporation of the phosphate monomer.

13.
J Nanosci Nanotechnol ; 18(3): 2037-2040, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29448707

RESUMO

The selective laser melting (SLM) process parameters, which directly determine the melting behavior of the metallic powders, greatly affect the nanostructure and surface roughness of the resulting 3D object. This study investigated the effect of various laser process parameters (laser power, scan rate, and scan line spacing) on the surface roughness of a nickel-chromium (Ni-Cr) alloy that was three-dimensionally (3D) constructed using SLM. Single-line formation tests were used to determine the optimal laser power of 200 W and scan rate of 98.8 mm/s, which resulted in beads with an optimal profile. In the subsequent multi-layer formation tests, the 3D object with the smoothest surface (Ra = 1.3 µm) was fabricated at a scan line spacing of 60 µm (overlap ratio = 73%). Narrow scan line spacing (and thus large overlap ratios) was preferred over wide scan line spacing to reduce the surface roughness of the 3D body. The findings of this study suggest that the laser power, scan rate, and scan line spacing are the key factors that control the surface quality of Ni-Cr alloys produced by SLM.

14.
Materials (Basel) ; 10(2)2017 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-28772489

RESUMO

This study investigated the influence of curing mode (dual- or self-cure) on the surface energy and sorption/solubility of four self-adhesive resin cements (SARCs) and one conventional resin cement. The degree of conversion (DC) and surface energy parameters including degree of hydrophilicity (DH) were determined using Fourier transform infrared spectroscopy and contact angle measurements, respectively (n = 5). Sorption and solubility were assessed by mass gain or loss after storage in distilled water or lactic acid for 60 days (n = 5). A linear regression model was used to correlate between the results (%DC vs. DH and %DC/DH vs. sorption/solubility). For all materials, the dual-curing consistently produced significantly higher %DC values than the self-curing (p < 0.05). Significant negative linear regressions were established between the %DC and DH in both curing modes (p < 0.05). Overall, the SARCs showed higher sorption/solubility values, in particular when immersed in lactic acid, than the conventional resin cement. Linear regression revealed that %DC and DH were negatively and positively correlated with the sorption/solubility values, respectively. Dual-curing of SARCs seems to lower the sorption and/or solubility in comparison with self-curing by increased %DC and occasionally decreased hydrophilicity.

15.
In Vivo ; 31(3): 335-341, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28438860

RESUMO

This study was undertaken to assess bone regeneration using hydroxyapatite (HA). The primary focus was comparison of bone regeneration between granular HA (gHA) forms and porous HA (pHA) scaffold. The extracted canine alveolar sockets were divided with three groups: control, gHA and pHA. Osteogenic effect in the gHA and pHA groups showed bone-specific surface and bone mineral density to be significantly higher than that of the control group (p<0.01). Bone volume fraction, bone mineral density, and amount of connective tissue related to disturbing osseointegration of the gHA group was higher than in the pHA group. Quantity of new bone formation of the pHA group was higher than that of the gHA group. This study demonstrated that gHA and pHA are potentially good bone substitutes for alveolar socket healing. For new bone formation during 8 weeks' post-implantation, HA with porous scaffold was superior to the granular form of HA.


Assuntos
Regeneração Óssea/efeitos dos fármacos , Regeneração Óssea/fisiologia , Substitutos Ósseos/farmacologia , Durapatita/farmacologia , Osteogênese/efeitos dos fármacos , Alvéolo Dental/efeitos dos fármacos , Animais , Tecido Conjuntivo/efeitos dos fármacos , Tecido Conjuntivo/fisiologia , Cães , Masculino , Osseointegração/efeitos dos fármacos , Osseointegração/fisiologia , Osteogênese/fisiologia , Alvéolo Dental/fisiologia , Cicatrização/efeitos dos fármacos , Cicatrização/fisiologia
16.
In Vivo ; 31(3): 373-379, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28438865

RESUMO

BACKGROUND/AIM: As an alternative material to the autogenous bone, duck-beak bone particle for bone substitute have been attracting great attention due to their biological properties. To deliver the most favorable outcome of medical treatment, it is essential to study the effect of various processing methods of the duck-beak bone. In this study, we compared the two deproteinizing agents for manufacturing duck-beak bone. Group 1 was treated by a conventional chemical agent (ethylenediamine) and Group 2 by hydrogen dioxide (H2O2). In vitro and in vivo experiments were conducted in parallel to compare the cytocompatibility and osteogenic capability between two processing methods. For in vitro tests, human adipose-derived mesenchymal stem cells (hAD-MSCs) were planted onto each sample and their attachment and growing were evaluated. For in vivo biocompatibility and osteogenic properties, the samples were applied on the critical-sized calvarial bone defect of rats. Group 2 showed significantly higher cell attachment but Group1 showed slightly higher cell proliferation. In in vivo tests, all groups have shown biocompatibility and increased level of osteogenic potential. However, Group 2 had significantly higher bone regeneration (p<0.05). This experiment confirmed that H2O2 can be an optimal processing method for duck-beak bone particle.


Assuntos
Bico/efeitos dos fármacos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Regeneração Óssea/efeitos dos fármacos , Peróxido de Hidrogênio/química , Osteogênese/efeitos dos fármacos , Tecido Adiposo/efeitos dos fármacos , Animais , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Patos , Etilenodiaminas/química , Humanos , Masculino , Células-Tronco Mesenquimais/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Alicerces Teciduais
17.
Implant Dent ; 26(3): 378-387, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28157816

RESUMO

PURPOSE: To develop a methodology for the synthesis of ß-tricalcium phosphate (ß-TCP, Ca3(PO4)2) from the shell of Haliotis sp. (abalone shell) and to verify its characterization and biocompatibility. MATERIALS AND METHODS: Calcium oxide (CaO) was synthesized from abalone shell by sintering and was suspended in distilled water to prepare calcium hydroxide (Ca(OH)2). For the synthesis of calcium carbonate (CaCO3), carbon dioxide was used to infuse Ca(OH)2 at pH 7.4. CaCO3 was reacted with phosphoric acid at pH 6.0 to obtain dicalcium phosphate (CaHPO4). Subsequently, ß-TCP was synthesized by a chemical reaction between CaHPO4 and CaO at 950°C to 1100°C for 3 hours. Fourier transform infrared spectroscopy (FT-IR) and x-ray diffraction (XRD) was performed to verify the physiochemical characteristics of the composite synthesized from abalone shell. RESULTS: FT-IR and XRD results showed that ß-TCP was successfully synthesized from abalone shell. The synthesized ß-TCP did not affect cell viability of either normal human oral keratinocytes or osteoblastic MG-63 cells. These data indicate that ß-TCP synthesized from abalone shell is biologically safe. CONCLUSIONS: ß-TCP (Ca3(PO4)2) synthesized from abalone shell can be used as a potential source of bone grafting material.


Assuntos
Exoesqueleto/química , Materiais Biocompatíveis/síntese química , Fosfatos de Cálcio/síntese química , Gastrópodes/química , Animais , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
18.
J Nanosci Nanotechnol ; 16(2): 1450-3, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27433603

RESUMO

A functional dental restorative system with antimicrobial properties was developed using zeolite (ZE) nanoparticles (NPs) as a drug delivery carrier. ZE NPs loaded with chlorhexidine (CHX) were prepared using the ionic immobilization method. The resulting CHX-loaded ZE NPs were then incorporated into commercial dental glass ionomer cement (GIC). The average size of the CHX-loaded ZE NPs was about 100 to 200 nm, and the NPs were dispersed homogeneously in the GIC. The in vitro release profile of encapsulated GIC containing CHX showed an early release burst of approximately 30% of the total CHX by day 7, whereas GIC containing CHX-loaded ZE NPs showed a sustained release of CHX without the early release burst in a 4-week immersion study. The agar diffusion test results showed that the GIC incorporated with CHX-loaded ZE NPs showed a larger growth inhibition zone of Streptococcus mutans than GIC alone, indicating that this innovative delivery platform potently imparted antimicrobial activity to the GIC. Moreover, these findings suggest that a range of antimicrobial drugs that inhibit the growth of oral bacteria can be incorporated efficiently into dental GIC using CHX-loaded ZE NPs.


Assuntos
Anti-Infecciosos , Clorexidina , Cimentos de Ionômeros de Vidro , Nanopartículas/química , Streptococcus mutans/crescimento & desenvolvimento , Zeolitas , Anti-Infecciosos/química , Anti-Infecciosos/farmacocinética , Anti-Infecciosos/farmacologia , Clorexidina/química , Clorexidina/farmacocinética , Clorexidina/farmacologia , Preparações de Ação Retardada/química , Preparações de Ação Retardada/farmacocinética , Preparações de Ação Retardada/farmacologia , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/farmacocinética , Cimentos de Ionômeros de Vidro/farmacologia , Zeolitas/química , Zeolitas/farmacocinética , Zeolitas/farmacologia
19.
J Nanosci Nanotechnol ; 16(2): 1883-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27433692

RESUMO

A simple and scalable surface modification treatment is demonstrated, in which nano- and microscale features are introduced into the surface of titanium (Ti) substrates by means of a novel and eco-friendly oxidative aqueous solution composed of hydrogen peroxide (H202) and sodium bicarbonate (NaHCO3). By immersing mirror-polished Ti discs in an aqueous mixture of 30 wt% H2O2/5 wt% NaHCO3 at 23 +/- 3 degrees C for 4 h, it was confirmed that this mixture is capable of generating microscale topographies on Ti surfaces. It also simultaneously formed nanochannels that were regularly arranged in a comb-like pattern on the Ti surface, thus forming a hierarchical surface structure. Further, these nano/micro-textured Ti surfaces showed great surface roughness and excellent wettability when compared with control Ti surfaces. This study demonstrates that a H2O2/NaHCO3 mixture can be effectively utilized to create reproducible nano/microscale topographies on Ti implant surfaces, thus providing an economical new oxidative solution that may be used effectively and safely as a Ti surface modification treatment.

20.
Biomed Res Int ; 2016: 2136215, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27042660

RESUMO

Bone defects are repaired using either natural or synthetic bone grafts. Poly(ϵ-caprolactone) (PCL), ß-tricalcium phosphate (TCP), and poly(lactic-co-glycolic acid) (PLGA) are widely used as synthetic materials for tissue engineering. This study aimed to investigate the bone-healing capacity of PCL/PLGA/duck beak scaffold in critical bone defects and the oxidative stress status of the graft site in a rabbit model. The in vivo performance of 48 healthy New Zealand White rabbits, weighing between 2.5 and 3.5 kg, was evaluated. The rabbits were assigned to the following groups: group 1 (control), group 2 (PCL/PLGA hybrid scaffolds), group 3 (PCL/PLGA/TCP hybrid scaffolds), and group 4 (PCL/PLGA/DB hybrid scaffolds). A 5 mm critical defect was induced in the diaphysis of the left radius. X-ray, micro-CT, and histological analyses were conducted at (time 0) 4, 8, and 12 weeks after implantation. Furthermore, bone formation markers (bone-specific alkaline phosphatase, carboxyterminal propeptide of type I procollagen, and osteocalcin) were measured and oxidative stress status was determined. X-ray, micro-CT, biochemistry, and histological analyses revealed that the PCL/PLGA/duck beak scaffold promotes new bone formation in rabbit radius by inducing repair, suggesting that it could be a good option for the treatment of fracture.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Regeneração Óssea , Osteogênese/efeitos dos fármacos , Estresse Oxidativo/efeitos dos fármacos , Engenharia Tecidual , Animais , Materiais Biocompatíveis/química , Transplante Ósseo/métodos , Fosfatos de Cálcio/química , Fosfatos de Cálcio/uso terapêutico , Humanos , Ácido Láctico/química , Ácido Láctico/uso terapêutico , Poliésteres/química , Poliésteres/uso terapêutico , Ácido Poliglicólico/química , Ácido Poliglicólico/uso terapêutico , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Coelhos , Alicerces Teciduais/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...