A peroxynitrite (ONOO(-)) biosensor has been developed through the preparation of a new manganese-[poly-2,5-di-(2-thienyl)-1H-pyrrole)-1-(p-benzoic acid)] (Mn-pDPB) complex. DPB monomer was first synthesized and polymerized for the purpose of providing a polymer backbone for complex formation with Mn(2+) ion. The Mn-pDPB complex was characterized via Magnetomotive Force (MMF) simulation, X-ray photoelectron spectroscopy (XPS), and cyclic voltammetry. The complex selectively enhanced the reduction process of ONOO(-) which was used as the analytical signal for chronoamperometric detection. A polyethyleneimmine (PEI) layer was coated on the complex surface to increase selectivity and stability. The chronoamperometric calibration plot showed the hydrodynamic range of 2.0 × 10(-8)-5.0 × 10(-7) M. The detection limit was determined to be 1.9 (±0.2) × 10(-9) M based on S/N = 3. The microbiosensor, fabricated on a 100 µm diameter Pt tip, was applied in a real rat plasma sample for the detection of spiked concentrations of ONOO(-). The reliability and long-term stability of the microbiosensor was also examined with YPEN-1 cells in vitro, and the results shown were promising.


Assuntos
Técnicas Biossensoriais/métodos , Condutividade Elétrica , Técnicas Eletroquímicas/métodos , Ácido Peroxinitroso/análise , Manganês/química , Polímeros/química
2.
Biosens Bioelectron ; 26(3): 1002-8, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20869230

RESUMO

A novel amperometric immunosensor with an enhanced sensitivity for the detection of neomycin (Neo) was prepared by covalently immobilizing a monoclonal Neo antibody onto a new conducting polymer, poly-[2,5-di-(2-thienyl)-1H-pyrrole-1-(p-benzoic acid)] (pDPB), as a sensor probe. The probe was used to detect Neo in a sandwich-type approach, where the secondary antibody was attached to gold nanoparticle-decorated multi-wall carbon nanotubes labeled with hydrazine (Hyd-MWCNT(AuNP)-Ab(2)). Hydrazine on the conjugate served as a catalyst for the reduction of hydrogen peroxide, and the catalytic current was monitored at -0.45 V vs. Ag/AgCl. The performance of the immunosensor with and without AuNPs on the probe and the conjugate was compared. The parameters affecting the immunosensor response in terms of antibody dilution ratio, incubation time, pH, applied potential, and temperature were optimized. A linear dynamic range for Neo analysis was obtained between 10 ng/mL and 250 ng/mL with a detection limit of 6.76 ± 0.17 ng/mL. The proposed immunosensor was successfully applied to detect Neo content in real meat samples.


Assuntos
Técnicas Biossensoriais/métodos , Nanopartículas Metálicas , Nanotubos de Carbono , Neomicina/análise , Animais , Anticorpos Imobilizados , Anticorpos Monoclonais , Técnicas Biossensoriais/estatística & dados numéricos , Técnicas Eletroquímicas , Contaminação de Alimentos/análise , Ouro , Hidrazinas , Carne/análise , Microscopia Eletrônica de Varredura , Neomicina/imunologia , Polímeros , Sensibilidade e Especificidade
3.
Anal Chem ; 81(16): 6604-11, 2009 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-20337374

RESUMO

Au nanoparticles-doped conducting polymer nanorods electrodes (AuNPs/CPNEs) were prepared by coating Au nanorods (AuNRs) with a conducting polymer layer. The AuNRs were prepared through an electroless deposition method using the polycarbonate membrane (pore diameter, 50 nm, pore density, 6 x 10(8) pores/cm(2)) as a template. The AuNPs/CPNEs combining catalytic activity of ferrocene to ascorbic acid were used for the fabrication of an ultrasensitive aptamer sensor for thrombin detection. The AuNPs/3D-CPNEs were characterized employing cyclic voltammetry (CV), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). Sandwiched immunoassay for alpha-human thrombin with NH(2)-functionalized-thrombin binding aptamer (Apt) immobilized on AuNPs/3D-CPNEs was studied through the electrocatalytic oxidation of ascorbic acid by the ferrocene moiety that was bound with an antithrombin antibody and attached with the Apt/3D-CPNEs probe through target binding. Various experimental parameters affecting thrombin detection were optimized, and the performance of the thrombin aptamer sensor was examined. The Apt/AuNPs/3D-CPNEs based thrombin sensor exhibited a wide dynamic range of 5-2000 ng L(-1) and a low detection limit of 5 ng L(-1) (0.14 pM). The selectivity and the stability of the proposed thrombin aptamer sensor were excellent, and it was tested in a real human serum sample for the detection of spiked concentrations of thrombin.


Assuntos
Aptâmeros de Nucleotídeos , Eletrodos , Compostos Ferrosos/química , Ouro/química , Nanopartículas Metálicas , Trombina/análise , Catálise , Metalocenos
4.
Biosens Bioelectron ; 23(11): 1595-601, 2008 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-18304799

RESUMO

An amperometric immunosensor was fabricated for the detection of osteoproteogerin (OPG) by covalently immobilizing a monoclonal OPG antibody (anti-OPG) onto the gold nanoparticles (AuNPs) deposited functionalized conducting polymer (5,2':5',2''-terthiophene-3'-carboxylic acid). AuNPs were electrochemically deposited onto the conducting polymer using cyclic voltammetry. The particle size of deposited AuNPs was controlled by varying the scan rate and was characterized by scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The immobilization of anti-OPG was also confirmed using XPS. The principle of immunosensor was based on a competitive immunoassay between free-OPG and labeled-OPG for the active sites of anti-OPG. HRP was used as a label that electrochemically catalyzes the H(2)O(2) reduction. The catalytic reduction was monitored amperometrically at -0.4V vs. Ag/AgCl. The immunosensor showed a linear range between 2.5 and 25pg/ml and the detection limit was determined to be 2pg/ml. The proposed immunosensor was successfully applied for real human samples to detect OPG.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Ouro/química , Imunoensaio/instrumentação , Nanopartículas/química , Osteoprotegerina/análise , Condutividade Elétrica , Galvanoplastia , Desenho de Equipamento , Análise de Falha de Equipamento , Osteoprotegerina/imunologia , Polímeros/química