Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur J Heart Fail ; 26(6): 1383-1392, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38741283

RESUMO

AIMS: We examined the effectiveness of a novel cardiopulmonary management wearable sensor (worn for less than 5 mins) at measuring congestion and correlated the device findings with established clinical measures of congestion. METHODS AND RESULTS: We enrolled three cohorts of patients: (1) patients with heart failure (HF) receiving intravenous diuretics in hospital; (2) patients established on haemodialysis, and (3) HF patients undergoing right heart catheterization (RHC). The primary outcomes in the respective cohorts were a Spearman correlation between (1) change in weight and change in thoracic impedance (TI) (from enrolment, 24 h after admission to discharge) in patients hospitalized for HF; (2) lung ultrasound B-lines and volume removed during dialysis with device measured TI, and (3) pulmonary capillary wedge pressure (PCWP) and sub-acoustic diastolic, third heart sound (S3) in the patients undergoing RHC. A total of 66 patients were enrolled. In HF patients (n = 25), change in weight was correlated with both change in device TI (Spearman correlation [rsp] = -0.64, p = 0.002) and change in device S3 (rsp = -0.53, p = 0.014). In the haemodialysis cohort (n = 21), B-lines and TI were strongly correlated before (rsp = -0.71, p < 0.001) and after (rsp = -0.77, p < 0.001) dialysis. Volume of fluid removed by dialysis was correlated with change in device TI (rsp = 0.49, p = 0.024). In the RHC cohort (n = 20), PCWP measured at one time point and device S3 were not significantly correlated (rsp = 0.230, p = 0.204). There were no device-related adverse events. CONCLUSIONS: A non-invasive device was able to detect changes in congestion in patients with HF receiving decongestion therapy and patients having fluid removed at haemodialysis. The cardiopulmonary management device, which measures multiple parameters, is a potentially useful tool to monitor patients with HF to prevent hospitalizations.


Assuntos
Insuficiência Cardíaca , Diálise Renal , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Masculino , Feminino , Diálise Renal/instrumentação , Diálise Renal/métodos , Idoso , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Dispositivos Eletrônicos Vestíveis , Pressão Propulsora Pulmonar/fisiologia , Cateterismo Cardíaco/métodos
2.
Card Fail Rev ; 9: e10, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37427007

RESUMO

Water and salt retention, in other words congestion, are fundamental to the pathophysiology of heart failure and are important therapeutic targets. Echocardiography is the key tool with which to assess cardiac structure and function in the initial diagnostic workup of patients with suspected heart failure and is essential for guiding treatment and stratifying risk. Ultrasound can also be used to identify and quantify congestion in the great veins, kidneys and lungs. More advanced imaging methods might further clarify the aetiology of heart failure and its consequences for the heart and periphery, thereby improving the efficiency and quality of care tailored with greater precision to individual patient need.

3.
JACC Cardiovasc Imaging ; 12(1): 96-105, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29248646

RESUMO

OBJECTIVES: The aim of this study was to establish sex differences in remodeling and outcome in aortic stenosis (AS) and their associations with biomarkers of myocardial fibrosis. BACKGROUND: The remodeling response and timing of symptoms is highly variable in AS, and sex plays an important role. METHODS: A total of 174 patients (133 men, mean age 66.2 ± 13.3 years) with asymptomatic moderate to severe AS underwent comprehensive stress cardiac magnetic resonance imaging, transthoracic echocardiography, and biomarker analysis (matrix metalloproteinase [MMP]-2, -3, -7, -8, and -9; tissue inhibitor matrix metalloproteinases-1 and -4; syndecan-1 and -4; and N-terminal pro-B-type natriuretic peptide), and were followed up at 6-month intervals. A primary endpoint was a composite of typical AS symptoms necessitating referral for aortic valve replacement, cardiovascular death, or major adverse cardiovascular events. RESULTS: For a similar severity of AS, male patients demonstrated higher indexed left ventricular (LV) volumes and mass, more concentric remodeling (higher LV mass/volume), a trend to more late gadolinium enhancement (present in 51.1% men vs. 34.1% women; p = 0.057), and higher extracellular volume index than female patients (13.27 [interquartile range (IQR): 11.5 to 17.0] vs. 11.53 [IQR: 10.5 to 13.5] ml/m2, p = 0.017), with worse systolic and diastolic function and higher MMP-3 and syndecan-4 levels, whereas female patients had higher septal E/e'. Male sex was independently associated with indexed LV mass (ß = 13.32 [IQR: 9.59 to 17.05]; p < 0.001). During median follow-up of 374 (IQR: 351 to 498) days, a primary outcome, driven by spontaneous symptom onset, occurred in 21.8% of male and 43.9% of female patients (relative risk: 0.50 [95% confidence interval: 0.31 to 0.80]; p = 0.004). Measures of AS severity were associated with the primary outcome in both sexes, whereas N-terminal pro-B-type natriuretic peptide, MMP-3, and mass/volume were only associated in men. CONCLUSIONS: In AS, women tolerate pressure overload with less concentric remodeling and myocardial fibrosis but are more likely to develop symptoms. This may be related to higher wall stress and filling pressures in women.


Assuntos
Estenose da Valva Aórtica/complicações , Disparidades nos Níveis de Saúde , Hipertrofia Ventricular Esquerda/etiologia , Miocárdio/patologia , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda , Remodelação Ventricular , Adaptação Fisiológica , Idoso , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Progressão da Doença , Ecocardiografia , Feminino , Fibrose , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/patologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Fatores de Tempo , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
4.
Echo Res Pract ; 6(1): 7-15, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30550376

RESUMO

Right ventricular (RV) dysfunction occurs following lung resection and is associated with post-operative complications and long-term functional morbidity. Accurate peri-operative assessment of RV function would have utility in this population. The difficulties of transthoracic echocardiographic (TTE) assessment of RV function may be compounded following lung resection surgery, and no parameters have been validated in this patient group. This study compares conventional TTE methods for assessing RV systolic function to a reference method in a lung resection population. Right ventricular index of myocardial performance (RIMP), fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE) and S' wave velocity at the tricuspid annulus (S'), along with speckle tracked global and free wall longitudinal strain (RV-GPLS and RV-FWPLS respectively) are compared with RV ejection fraction obtained by cardiovascular magnetic resonance (RVEFCMR). Twenty-seven patients undergoing lung resection underwent contemporaneous CMR and TTE imaging; pre-operatively, on post-operative day two and at 2 months. Ability of each of the parameters to predict RV dysfunction (RVEFCMR <45%) was assessed using the area under the receiver operating characteristic curve (AUROCC). RIMP, FAC and S' demonstrated no predictive value for poor RV function (AUROCC <0.61, P > 0.05). TAPSE performed marginally better with an AUROCC of 0.65 (P = 0.04). RV-GPLS and RV-FWPLS demonstrated good predictive ability with AUROCC's of 0.74 and 0.76 respectively (P < 0.01 for both). This study demonstrates that the conventional TTE parameters of RV systolic function are inadequate following lung resection. Longitudinal strain performs better and offers some ability to determine poor RV function in this challenging population.

5.
Eur J Heart Fail ; 20(9): 1338-1347, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29952090

RESUMO

AIMS: We investigated which patients with heart failure (HF) should receive specialist palliative care (SPC) by first creating a definition of need for SPC in patients hospitalised with HF using patient-reported outcome measures (PROMs) and then testing this definition using the outcome of days alive and out of hospital (DAOH). We also evaluated which baseline variables predicted need for SPC and whether those with this need received SPC. METHODS AND RESULTS: PROMs assessing quality of life (QoL), symptoms, and mood were administered at baseline and every 4 months. SPC need was defined as persistently severe impairment of any PROM without improvement (or severe impairment immediately preceding death). We then tested whether need for SPC, so defined, was reflected in DAOH, a measure which combines length of stay, days of hospital re-admission, and days lost due to death. Of 272 patients recruited, 74 (27%) met the definition of SPC needs. These patients lived one third fewer DAOH than those without SPC need (and less than a quarter of QoL-adjusted DAOH). A Kansas City Cardiomyopathy Questionnaire (KCCQ) summary score of <29 identified patients who subsequently had SPC needs (area under receiver operating characteristic curve 0.78). Twenty-four per cent of patients with SPC needs actually received SPC (n = 18). CONCLUSIONS: A quarter of patients hospitalised with HF had a need for SPC and were identified by a low KCCQ score on admission. Those with SPC need spent many fewer DAOH and their DAOH were of significantly worse quality. Very few patients with SPC needs accessed SPC services.


Assuntos
Insuficiência Cardíaca/terapia , Cuidados Paliativos/estatística & dados numéricos , Medidas de Resultados Relatados pelo Paciente , Seleção de Pacientes , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Cuidados Paliativos/métodos , Prevalência , Estudos Retrospectivos , Especialização , Reino Unido/epidemiologia
7.
Innovations (Phila) ; 11(2): 84-93, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26889881

RESUMO

OBJECTIVE: This study aimed to evaluate a novel device system for surgical aortic valve replacement (SAVR) using a unique new less invasive access approach. The hypothesis is that SAVR can be performed through a short transverse incision in the neck, similar to that used for transcervical thymectomy avoiding chest disruption. METHODS: A new device system was developed to provide retraction, step-by-step illumination, and on-screen visualization for the new approach. Preliminary feasibility studies were performed in cadavers. Comprehensive risk analysis was performed, and training was implemented in Thiel preserved cadavers. For the first-in-man clinical case, a 63-year-old woman with symptomatic critical aortic stenosis (The Society of Thoracic Surgeons risk, 11%) and heavily calcified aortic valve was selected. A short transverse incision was made in the neck; the device was introduced, and the sternum was elevated; femorofemoral cardiopulmonary bypass was established; substernal dissection was guided by the sequenced illumination, and high-definition visualization was provided by the device, allowing for optimal exposition of the aorta and aortic valve; and a 23-mm Medtronic ENABLE sutureless valve prosthesis was implanted. Procedure success was evaluated according to the standardized composite end point definition of "device success" proposed by the Valve Academic Research Consortium. RESULTS: Access, delivery, and deployment of the valve prosthesis were successful. The correct position and intended performance of the valve were demonstrated (mean gradient, 6 mm Hg; aortic valve area, 2.5 cm) with the absence of moderate or severe prosthetic aortic regurgitation. Only one valve prosthesis was used. CONCLUSIONS: Transcervical SAVR with sutureless valve is feasible using this novel access system. The new approach has potential to offer patients substantially shorter stay and fewer, less serious complications, as has been observed in transcervical thymectomy. Further studies are merited.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ponte Cardiopulmonar/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Ponte Cardiopulmonar/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Pescoço/cirurgia , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
9.
Scand J Infect Dis ; 42(10): 791-3, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20482456

RESUMO

Following the advent of antibiotics, pneumococcal pericarditis has become a rare clinical diagnosis. We discuss 2 cases of pneumococcal pericarditis that were preceded by community-acquired pneumonia. Cultures were negative in both patients and the diagnosis was made by antigen testing and polymerase chain reaction (PCR) of the pericardial fluid. PCR or antigen testing of pericardial fluid for pneumococci should be considered in patients with a typical history, particularly when culture-negative and with a history of prior antibiotics.


Assuntos
Antígenos de Bactérias/análise , Pericardite/diagnóstico , Infecções Pneumocócicas/diagnóstico , Reação em Cadeia da Polimerase/métodos , Streptococcus pneumoniae/genética , Streptococcus pneumoniae/isolamento & purificação , Adulto , Infecções Comunitárias Adquiridas/complicações , Infecções Comunitárias Adquiridas/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/microbiologia , Pericardite/microbiologia , Infecções Pneumocócicas/microbiologia , Pneumonia Pneumocócica/complicações , Pneumonia Pneumocócica/microbiologia , Streptococcus pneumoniae/classificação , Streptococcus pneumoniae/imunologia , Adulto Jovem
10.
Eur J Echocardiogr ; 11(2): 192-4, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19939816

RESUMO

We report the case of a 76-year-old lady who had a mitral valve (MV) replacement for severe MV stenosis. Several days following the procedure, a routine transthoracic echocardiogram (TTE) was performed. Despite the prosthesis leaflets opening well anterograde maximum velocities were elevated; MV peak velocity of 2.4 m/s. A transoesophageal echocardiogram (TEE) demonstrated the superior strut of the prosthesis appearing to rotate inwards such that the ventricular (non-fixed) end of the struts approximate to one another during systole, reducing the effective orifice area for anterograde flow. A 3D TEE was performed. This showed that the valve struts were not parallel, with the planes of the struts converging from the base to the apex. However, this abnormal conformation appeared to be fixed rather than worsening in systole. The apparent movement of the posterior strut seen in the 2D TEE images appears to have resulted from systole movement of this strut partially out of the plane of the TEE (2D) cut. We believe the case demonstrates the value of 3D real-time TEE in the assessment of the MV prosthesis function.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Estenose da Valva Mitral/cirurgia
11.
Kardiol Pol ; 60(3): 247-9, 2004 Mar.
Artigo em Polonês | MEDLINE | ID: mdl-15156220

RESUMO

We describe a case of a 55-year-old male with anterior myocardial infarction, treated in the acute phase with thrombolysis. Transthoracic echocardiography showed hypokinetic apical segments, ejection fraction of 55% and reduced coronary flow reserve in the left anterior descending (LAD) coronary artery. Elective coronary angiography revealed a borderline (40-50%) lesion in LAD. The patient underwent successful angioplasty of LAD with stent implantation. Non-invasive coronary flow reserve measurements were repeated 3 days, 6 weeks and 6 months after angioplasty showing continuous improvement in this parameter. The role of non-invasive echocardiographic assessment of coronary flow reserve in the selection for angioplasty and monitoring of the effects of treatment is discussed.


Assuntos
Circulação Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Infarto do Miocárdio/diagnóstico por imagem , Trifosfato de Adenosina/farmacologia , Velocidade do Fluxo Sanguíneo , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Vasos Coronários/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...