Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Environ Sci (China) ; 148: 198-209, 2025 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39095157

RESUMO

Norfloxacin is widely used owing to its strong bactericidal effect on Gram-negative bacteria. However, the residual norfloxacin in the environment can be biomagnified via food chain and may damage the human liver and delay the bone development of minors. Present work described a reliable and sensitive smartphone colorimetric sensing system based on cobalt-doped Fe3O4 magnetic nanoparticles (Co-Fe3O4 MNPs) for the visual detection of norfloxacin. Compared with Fe3O4, Co-Fe3O4 MNPs earned more remarkably peroxidase-like activity and TMB (colorless) was rapidly oxidized to oxTMB (blue) with the presence of H2O2. Interestingly, the addition of low concentration of norfloxacin can accelerate the color reaction process of TMB, and blue deepening of the solution can be observed with the naked eye. However, after adding high concentration of norfloxacin, the activity of nanozyme was inhibited, resulting in the gradual fading of the solution. Based on this principle, a colorimetric sensor integrated with smartphone RGB mode was established. The visual sensor exhibited good linearity for norfloxacin monitoring in the range of 0.13-2.51 µmol/L and 17.5-100 µmol/L. The limit of visual detection was 0.08 µmol/L. In the actual water sample analysis, the spiked recoveries of norfloxacin were over the range of 95.7%-104.7 %. These results demonstrated that the visual sensor was a convenient and fast method for the efficient and accurate detection of norfloxacin in water, which may have broad application prospect.


Assuntos
Cobalto , Colorimetria , Norfloxacino , Smartphone , Poluentes Químicos da Água , Norfloxacino/análise , Colorimetria/métodos , Cobalto/análise , Cobalto/química , Poluentes Químicos da Água/análise , Antibacterianos/análise , Peroxidase , Limite de Detecção
2.
J Colloid Interface Sci ; 678(Pt B): 266-276, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39245017

RESUMO

The residual carbaryl in crops can cause serious damage to the human kidney and nervous system after entering the human body, which may be metabolized to 1-naphthol (1-NAP) and excreted through urine. 1-NAP is often used as the biomarker for carbaryl exposure, so the intake or leakage of carbaryl can be monitored by detecting the concentration of 1-NAP. Herein, Co, N, P ternary co-doped carbon dots (CoNP-CDs) derived from vitamin B12 were synthesized by a facile hydrothermal method. CoNP-CDs exhibited oxidase-like activity and excellent peroxidase-like activity, which was attributed to the Fenton-like reaction of Co2+/Co3+ and the presence of pyrrole N and P elements, which together provided multiple active sites for chromogenic substrates. Due to the dual enzyme-like activity of CoNP-CDs, hydroxyl radicals (OH) and superoxide radicals (O2-) were generated during the catalytic process, which could rapidly oxidize colorless 3,3',5,5'-tetramethyl benzidine (TMB) to blue oxidation products (oxTMB). The α-carbon in 1-NAP can be attacked by OH, and the catalytic oxidation process of TMB can be inhibited by the consumption of OH, so that the blue color of the solution became lighter. Based on this principle, a smartphone-assisted colorimetric sensing platform was constructed for the detection of 1-NAP, and which resulted in a linear range of 1.07-37.3 µM and a visual detection limit of 0.68 µM. Moreover, the colorimetric sensing system showed satisfactory recoveries in the detection of human urine samples. The colorimetric sensing system owned the advantages of fast response, strong selectivity and simple operation, and provided a potential strategy for the on-site detection of 1-NAP.

3.
J Hazard Mater ; 479: 135653, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39217939

RESUMO

In this study, a novel COFTABT@COFTATp modified magnetic MXene composite (CoFe2O4 @Ti3C2 @COFTABT@COFTATp) was synthesized by Schiff base reaction and irre-versible enol-keto tautomerization, and employed to establish a sensitive monitoring method for six thiophene compounds in oilfield produced water samples based on magnetic solid-phase extraction (MSPE) prior to gas chromatography coupled with a triple quadruple mass spectrometer (GC-MS/MS). The designed magnetic materials exhibited unexpected enrichment ability to target thiophene compounds and achieved good extraction efficiencies ranging from 83 % to 98 %. The developed MSPE/GC-MS/MS method exhibited good linearity in the range of 0.001-100 µg L-1, and obtained lower limits of detection ranging from 0.39 to 1.9 ng L-1. The spiked recoveries of thiophene compounds obtained in three oilfield produced water samples were over the range of 96.26 %-99.54 % with relative standard deviations (RSDs) less than 3.7 %. Notably, benzothiophene, 4-methyldibenzothiophene and 4,6-dimethyldibenzothiophene were detected in three oilfield-produced water samples. Furthermore, the material still kept favorable stability after six recycling experiments. The adsorption kinetics, adsorption isotherms as well as adsorption thermodynamics of thiophene compounds were investigated in detail to provide insight into the mechanisms. Overall, the present work contributed a promising strategy for designing and synthesizing new functionalized materials for the enrichment and detection of typical pollutants in the environment.

4.
Food Chem ; 459: 140352, 2024 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38991447

RESUMO

In this study, a hydrophobic covalent organic framework-functionalized magnetic composite (CoFe2O4@Ti3C2@TAPB-TFTA) with a high specific area with 1,3,5-tris(4-aminophenyl)benzene (TAPB) and 2,3,5,6-tetrafluoroterephthalaldehyde (TFTA) was designed and synthesized through Schiff base reaction. An efficient magnetic solid-phase extraction method was established and combined with gas chromatography-triple quadrupole mass spectrometry to sensitively determine 10 organochlorine and organophosphorus pesticides in tea samples. The established method exhibited good linearity in the range of 0.05-120 µg/L and had low limits of detection (0.013-0.018 µg/L). The method was evaluated with tea samples, and the spiked recoveries of pesticides in different tea samples reached satisfactory values of 85.7-96.8%. Moreover, the adsorption of pesticides was spontaneous and followed Redlich-Peterson isotherm and pseudo-second-order kinetic models. These results demonstrate the sensitivity, effectiveness, and reliability of the proposed method for monitoring organochlorine and organophosphorus pesticides in tea samples, providing a preliminary basis for researchers to reasonably design adsorbents for the efficient extraction of pesticides.


Assuntos
Contaminação de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Hidrocarbonetos Clorados , Estruturas Metalorgânicas , Nanocompostos , Compostos Organofosforados , Praguicidas , Extração em Fase Sólida , Chá , Chá/química , Compostos Organofosforados/química , Compostos Organofosforados/análise , Hidrocarbonetos Clorados/química , Hidrocarbonetos Clorados/análise , Contaminação de Alimentos/análise , Nanocompostos/química , Estruturas Metalorgânicas/química , Extração em Fase Sólida/métodos , Praguicidas/química , Praguicidas/análise , Adsorção , Limite de Detecção , Resíduos de Praguicidas/química , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação
5.
Food Chem ; 459: 140452, 2024 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-39024871

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are commonly found in various environmental matrices and have received significant attention due to their toxic effects on ecosystems and environmental health. In this study, a specific magnetic composite material derived from MXene, known as phenyl-functionalized NiFe2O4@Ti3C2TX, was designed and synthesized using a simple method. This composite material was used to develop an effective magnetic solid-phase extraction (MSPE) method for enriching trace polycyclic aromatic hydrocarbons (PAHs) in tea and coffee samples. The eluted PAHs were analyzed via gas chromatography-tandem mass spectrometry. Under optimal conditions, this method exhibited excellent linear relationships for 16 PAHs within the ranges of 0.001-25 and 0.0005-25 µg/L, with correlation coefficients exceeding 0.9979. The limits of detection for the target PAHs ranged from 0.1 to 0.3 ng/L. The effectiveness of the proposed method was evaluated by analyzing tea and coffee samples, and the satisfactory spiked recoveries of PAHs ranged from 84.5% to 112.6%.


Assuntos
Café , Contaminação de Alimentos , Hidrocarbonetos Policíclicos Aromáticos , Extração em Fase Sólida , Chá , Chá/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/isolamento & purificação , Hidrocarbonetos Policíclicos Aromáticos/química , Café/química , Extração em Fase Sólida/métodos , Contaminação de Alimentos/análise , Níquel/química , Níquel/análise , Níquel/isolamento & purificação , Compostos Férricos/química , Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção
6.
J Colloid Interface Sci ; 667: 403-413, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38640659

RESUMO

In this study, nitrogen-doped carbon dots (N-CDs) were facilely fabricated by one-pot hydrothermal method with levulinic acid and triethanolamine. A fluorescent sensor array was established for identifying azo compounds including Sudan Orange G (SOG), p-diaminoazobenzene, p-aminoazobenzene, azobenzene and quantitative detection of SOG. Experimental results revealed that azo compounds could quench the fluorescent intensity of N-CDs. Owing to various azo compounds showing different affinities to N-CDs, the sensor array exhibited different fluorescence quenching changes, which were further analyzed with principal component analysis to discriminate azo compounds. The sensor array was able to differentiate and recognize diverse concentrations of azo compounds from 0.25 to 2 mg/L. Simultaneously, a variety of factors affecting the detection of SOG were optimized. Under the optimized conditions, the sensor showed excellent stability and sensitivity. The sensor possessed marvelous linearity in the range of 0.1-1 mg/L and 1-4 mg/L and the detection limit was 27.82 µg/L. Spiked recoveries of 90.8-98.2 % were attained at spiked levels of 0.2 mg/L and 1 mg/L, demonstrating that the constructed fluorescence sensor was dependable and feasible for sensing SOG in environmental water samples.

7.
Talanta ; 275: 126119, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38640521

RESUMO

Present work reported a novel nanozyme g-C3N4@Cu, N-CDs with excellent peroxidase-like activity obtained by loading Cu and N co-doped carbon dots on g-C3N4 (graphitic carbon nitride). g-C3N4@Cu, N-CDs can catalyze H2O2 to generate hydroxyl radical •OH, which oxidizes o-phenylenediamine to 2,3-diaminophenazine, which emits orange fluorescence under ultraviolet light irradiation. The experimental results confirmed that 1,4-benzenedithiol (BDT) could inhibit the peroxidase-like activity of g-C3N4@Cu, N-CDs. Based the principle above, a colorimetric-fluorescence dual-mode sensor for rapidly sensing of BDT was creatively constructed with assisting of a smartphone. The sensor showed excellent linearity over ranges of 0.75-132 µM and 0.33-60.0 µM with detection limits of 0.32 µM and 0.25 µM for colorimetric and fluorescence detection, respectively. Moreover, a smartphone-assisted colorimetric array sensor was constructed to distinguish six sulfur-containing compounds according to the difference in the degree of inhibition of nanozyme activity by different sulfur-containing compounds. The array sensor could distinguish sulfur-containing compounds at low concentration as low as 0.4 µM. The results validated that the designed sensor was a convenient and fast platform, which could be utilized as a reliably portable tool for the efficient and accurate detection of BDT and the discrimination of multiple sulfur compounds in real water samples.


Assuntos
Colorimetria , Cobre , Smartphone , Sulfetos , Colorimetria/métodos , Cobre/química , Sulfetos/química , Compostos de Cádmio/química , Poluentes Químicos da Água/análise , Peroxidase/química , Peroxidase/metabolismo , Fluorescência , Compostos de Enxofre/análise , Compostos de Enxofre/química , Limite de Detecção , Espectrometria de Fluorescência/métodos , Compostos de Sulfidrila/química , Compostos de Sulfidrila/análise , Carbono/química , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Grafite , Compostos de Nitrogênio
8.
Talanta ; 272: 125749, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38359723

RESUMO

In this work, a sensitive fluorescent sensor toward p-nitrophenol (4-NP) integrating magnetic molecularly imprinted materials and carbon dots (CDs) was proposed. Magnetic material and CDs derived from K3 [Fe(CN)6] and glucose were simultaneously obtained through simple one-step hydrothermal process. Introducing of molecularly imprinted materials based magnetic solid phase extraction (MSPE) endowed the constructed fluorescent sensor with higher sensitivity and selectivity. The significant factors affecting the sensitivity of the sensor toward 4-NP were optimized. Good linearity was obtained between fluorescent intensity of CDs and different concentration of 4-NP from 0.08 to 62.5 µg L-1. The sensitivity of constructed sensor was very low with detection limit of 0.02 µg L-1. Reliable applicability was also proved by the well-pleasing recoveries of 94.2-97.8% with different spiked concentrations of 4-NP in real environmental waters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA