Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Light Sci Appl ; 11(1): 329, 2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36414615

RESUMO

The solar X-ray and Extreme Ultraviolet Imager (X-EUVI), developed by the Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences (CIOMP), is the first space-based solar X-ray and Extreme ultraviolet (EUV) imager of China loaded on the Fengyun-3E (FY-3E) satellite supported by the China Meteorological Administration (CMA) for solar observation. Since started work on July 11, 2021, X-EUVI has obtained many solar images. The instrument employs an innovative dual-band design to monitor a much larger temperature range on the Sun, which covers 0.6-8.0 nm in the X-ray region with six channels and 19.5 nm in the EUV region. X-EUVI has a field of view of 42', an angular resolution of 2.5″ per pixel in the EUV band and an angular resolution of 4.1″ per pixel in the X-ray band. The instrument also includes an X-ray and EUV irradiance sensor (X-EUVS) with the same bands as its imaging optics, which measures the solar irradiance and regularly calibrates the solar images. The radiometric calibration of X-EUVS on the ground has been completed, with a calibration accuracy of 12%. X-EUVI is loaded on the FY-3E satellite and rotates relative to the Sun at a uniform rate. Flat-field calibration is conducted by utilizing successive rotation solar images. The agreement between preliminarily processed X-EUVI images and SDO/AIA and Hinode/XRT images indicates that X-EUVI and the data processing algorithm operate properly and that the data from X-EUVI can be applied to the space weather forecast system of CMA and scientific investigations on solar activity.

2.
Sensors (Basel) ; 20(20)2020 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-33096841

RESUMO

The radiation intensity of observed auroras in the far-ultraviolet (FUV) band varies dramatically with location for aerospace applications, requiring a photon counting imaging apparatus with a wide dynamic range. However, combining high spatial resolution imaging with high event rates is technically challenging. We developed an FUV photon counting imaging system for aurora observation. Our system mainly consists of a microchannel plate (MCP) stack readout using a wedge strip anode (WSA) with charge induction and high-speed electronics, such as a charge sensitive amplifier (CSA) and pulse shaper. Moreover, we constructed an anode readout model and a time response model for readout circuits to investigate the counting error in high counting rate applications. This system supports global rates of 500 kilo counts, 0.610 dark counts s-1 cm-2 at an ambient temperature of 300 K and 111 µm spatial resolution at 400 kilo counts s-1 (kcps). We demonstrate an obvious photon count loss at incident intensities close to the counting capacity of the system. To preserve image quality, the response time should be improved and some noise performance may be sacrificed. Finally, we also describe the correlation between counting rate and imaging resolution, which further guides the design of space observation instruments.

3.
Light Sci Appl ; 8: 47, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31123586

RESUMO

The newly launched Fengyun-3D (FY-3D) satellite carried a wide-field auroral imager (WAI) that was developed by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences (CIOMP), which will provide a large field of view (FOV), high spatial resolution, and broadband ultraviolet images of the aurora and the ionosphere by imaging the N2 LBH bands of emissions. The WAI consists of two identical cameras, each with an FOV of 68° in the along-track direction and 10° in the cross-track direction. The two cameras are tilted relative to each other to cover a fan-shaped field of size 130° × 10°. Each camera consists of an unobstructed four-mirror anastigmatic optical system, a BaF2 filter, and a photon-counting imaging detector. The spatial resolution of WAI is ~10 km at the nadir point at a reference height of 110 km above the Earth's surface. The sensitivity is >0.01 counts s-1 Rayleigh-1 pixel-1 (140-180 nm) for both cameras, which is sufficient for mapping the boundaries and the fine structures of the auroral oval during storms/substorms. Based on the tests and calibrations that were conducted prior to launch, the data processing algorithm includes photon signal decoding, geometric distortion correction, photometric correction, flat-field correction, line-of-sight projection and correction, and normalization between the two cameras. Preliminarily processed images are compared with DMSP SSUSI images. The agreement between the images that were captured by two instruments demonstrates that the WAI and the data processing algorithm operate normally and can provide high-quality scientific data for future studies on auroral dynamics.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(12): 3334-8, 2015 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-26964205

RESUMO

Based-MCP position-sensitive anode photon-counting imaging detector is good at detecting extremely faint light, which includes micro-channel plate (MCP), position-sensitive anode and readout, and the performances of these detectors are mainly decided by the position-sensitive anode. As a charge division anode, Vernier anode using cyclically varying electrode areas which replaces the linearly varying electrodes of wedge-strip anode can get better resolution and greater electrode dynamic range. Simulation and design of the Vernier anode based on Vernier's decode principle are given here. Firstly, we introduce the decode and design principle of Vernier anode with nine electrodes in vector way, and get the design parameters which are the pitch, amplitude and the coarse wavelength of electrode. Secondly, we analyze the effect of every design parameters to the imaging of the detector. We simulate the electron cloud, the Vernier anode and the detector imaging using Labview software and get the relationship between the pitch and the coarse wavelength of the anode. Simultaneously, we get the corresponding electron cloud for the designing parameters. Based on the result of the simulation and the practical machining demand, a nine electrodes Vernier anode was designed and fabricated which has a pitch of 891 µm, insulation width of 25 µm, amplitude of 50 µm, coarse pixel numbers of 5.

5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(12): 1489-93, 2004 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-15828308

RESUMO

The picosecond time-correlated single photon counting spectrometer developed uses the TCSPC technique and grating splitter technique that can compensate the time spread dynamically and statically. The time spread caused by the conventional optical system can be eliminated completely. The multichannel analyzer is used to measure the fluorescence decay curves and the time-resolved spectrum by opening the time windows. The method for multi-exponential fitting to the fluorescence decay is also used to deal with the data. The system theory and design of the spectrometer are presented in detail, and the process of operation is introduced with the integration of the system. Many standard samples have been measured, and the data have been analyzed and contrasted. Experimental results show that the fluorescence life-span scaled by the spectrometer reaches picosecond distinction, and the spectrometer's sensitivity is single photon counting. Time resolution of the spectrometer is 8.8 ps.


Assuntos
Desenho de Equipamento/métodos , Análise Espectral/métodos , Armazenamento e Recuperação da Informação , Luz , Modelos Estatísticos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...