Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Shokuhin Eiseigaku Zasshi ; 57(6): 222-229, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-28025457

RESUMO

The Japanese Food Sanitation Law sets a limit on the migration level of caprolactam for food-contacting nylon products. Here, we carried out an interlaboratory study in twenty laboratories to evaluate the performance of the official GC-FID test method and a GC-MS method as an alternative test method to the official method. Each laboratory quantified caprolactam in three test solutions in 20% ethanol as blind duplicates using GC-FID or GC-MS. The official method (GC-FID with absolute calibration) gave trueness, repeatability (RSDr) and reproducibility (RSDr) values of 96-97%, 3.3-5.4% and 4.0-6.7%, respectively. These values met the target criteria (trueness: 80-110%, RSDr: 10%, RSDr: 25%). The performance of the method was further improved by the introduction of heptalactam as an internal standard. As for GC-MS method, some values of the RSDr exceeded 10% when absolute calibration was used. However, when an internal standard was introduced, the trueness, RSDr and RSDr of GC-MS method were all acceptable at 94-96%, 2.0-4.4% and 7.0-9.4%, respectively. Therefore, GC-MS with an internal standard is available as an alternative test method to the official method.


Assuntos
Caprolactama/análise , Utensílios de Alimentação e Culinária , Análise de Alimentos/métodos , Embalagem de Alimentos , Laboratórios , Nylons/química , Cromatografia Gasosa , Inocuidade dos Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Legislação sobre Alimentos/normas , Espectrometria de Fluorescência
2.
Shokuhin Eiseigaku Zasshi ; 57(5): 169-178, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-27784869

RESUMO

Using polystyrene, acrylonitrile-styrene resin and acrylonitrile-butadiene-styrene resin pellets as samples, an interlaboratory study was performed to evaluate the volatiles test method, based on the specifications described in the Japanese Food Sanitation Law for food-contacting polystyrene products. The study was conducted with the participation of twenty-one laboratories. Each laboratory quantified the contents of styrene, toluene, ethylbenzene, isopropylbenzene and propylbenzene in three test pellets using GC-FID, GC-MS or headspace-GC-FID. Statistical analysis revealed that the repeatability (RSDr) and reproducibility (RSDr) were 1.0-2.6 and 2.5-5.5% for the GC-FID method. The values of the performance parameters fulfilled the requirements (RSDr: 10%, RSDr: 25%), and the performance is sufficient for specifications testing. The RSDr and RSDr of results obtained using the GC-MS and HS-GC methods were 1.4-7.8 and 4.9-13%(GC-MS), and 2.0-2.6 and 3.3-6.9%(HS-GC-FID), respectively. The quantified levels were similar to those obtained with GC-FID. The study suggests that the GC-MS and HS-GC methods can be employed as alternative methods to the GC-FID method.


Assuntos
Resinas Acrílicas/química , Butadienos/química , Utensílios de Alimentação e Culinária , Embalagem de Alimentos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Poliestirenos/química , Compostos Orgânicos Voláteis/análise , Derivados de Benzeno/análise , Japão , Laboratórios , Legislação sobre Alimentos , Reprodutibilidade dos Testes , Espectrometria de Fluorescência/métodos , Estireno/análise , Tolueno/análise
3.
Shokuhin Eiseigaku Zasshi ; 56(3): 123-31, 2015.
Artigo em Japonês | MEDLINE | ID: mdl-26156169

RESUMO

Using six kinds of zinc solution in water and 4% acetic acid as samples, an interlaboratory study was performed to evaluate a zinc (Zn) test method for food-contact rubber products, based on the Japanese Food Sanitation Law. Eighteen laboratories participated, and quantified Zn in six test solutions as blind duplicates using flame atomic absorption spectrometry, induced coupled plasma-optical emission spectrometry or induced coupled plasma-mass spectrometry. Statistical analysis revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 97-103%, 0.7-4.9% and 1.7-8.9% by all measuring methods. The values of the performance parameter fulfilled the target value (trueness: 80-110%, RSDr: 10%, RSDr: 25%). The performance of these methods is sufficient for testing the adherence of samples to the specifications.


Assuntos
Utensílios de Alimentação e Culinária , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Embalagem de Alimentos , Análise de Perigos e Pontos Críticos de Controle/métodos , Espectrometria de Massas/métodos , Borracha/química , Espectrofotometria Atômica/métodos , Zinco/análise , Estudos de Viabilidade , Inocuidade dos Alimentos , Reprodutibilidade dos Testes , Soluções
4.
Shokuhin Eiseigaku Zasshi ; 56(2): 57-67, 2015.
Artigo em Japonês | MEDLINE | ID: mdl-25925077

RESUMO

An interlaboratory study was performed to evaluate a migration test method of antimony (Sb) and germanium (Ge), based on the Japanese Food Sanitation Law for food- contact polyethylene terephthalate. Eighteen laboratories participated, and quantified Sb and Ge in three test solutions as blind duplicates using graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES) or induced coupled plasma-mass spectrometry (ICP-MS). Statistical analysis revealed that the trueness, repeatability and reproducibility were 98-107%, 1.7-7.5% and 2.0-18.8% by using GF-AAS and ICP-OES. The performance of these methods is sufficient for testing the specifications. The performance parameters of ICP-MS were 99-106%, 0.7-2.2% and 2.2-10.5%, respectively. ICP-MS is available as an alternative measuring method. However, in some laboratories, the quantitative values of Sb were higher than the addition levels. We found that Sb in working solutions is absorbed on glass vessels. Careful control of concentration in working solutions is required for Sb analysis.


Assuntos
Antimônio/análise , Utensílios de Alimentação e Culinária , Embalagem de Alimentos , Germânio/análise , Análise de Perigos e Pontos Críticos de Controle/métodos , Laboratórios/normas , Polietilenotereftalatos/química , Inocuidade dos Alimentos , Japão , Legislação sobre Alimentos , Espectrometria de Massas , Reprodutibilidade dos Testes , Soluções , Espectrofotometria Atômica
5.
Shokuhin Eiseigaku Zasshi ; 55(2): 117-34, 2014.
Artigo em Japonês | MEDLINE | ID: mdl-24990558

RESUMO

An interlaboratory study was performed to evaluate a migration test method of cadmium (Cd) and lead (Pb), based on the Japanese Food Sanitation Law for glassware, ceramicware, enamelware and metal cans. Seventeen laboratories participated, and quantified Cd and Pb in eight test solutions as blind duplicates using flame atomic absorption spectrometry (AAS), graphite furnace atomic absorption spectrometry (GF-AAS), inductively coupled plasma-optical emission spectrometry (ICP-OES) or induced coupled plasma-mass spectrometry (ICP-MS). Statistical analysis revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 93-105%, 0.7-8.4% and 2.6-19.3% by using AAS, ICP-OES and ICP-MS (internal standard method). The performance of these methods is sufficient for testing specifications. However, some of the RSDr values exceeded 10% in GF-AAS, and careful control of accuracy is required.


Assuntos
Cádmio/análise , Utensílios de Alimentação e Culinária/legislação & jurisprudência , Utensílios de Alimentação e Culinária/normas , Contaminação de Alimentos/prevenção & controle , Embalagem de Alimentos/legislação & jurisprudência , Embalagem de Alimentos/normas , Laboratórios/normas , Chumbo/análise , Legislação sobre Alimentos/normas , Espectrometria de Massas/métodos , Espectrofotometria Atômica/métodos , Ácido Acético , Ácido Cítrico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soluções , Água
6.
Shokuhin Eiseigaku Zasshi ; 55(6): 269-78, 2014.
Artigo em Japonês | MEDLINE | ID: mdl-25743590

RESUMO

Based on the Japanese Food Sanitation Law, the performances of official and alternative material test methods for cadmium (Cd) and lead (Pb) in food contact plastics were compared. Nineteen laboratories participated to an interlaboratory study, and quantified Cd and Pb in three PVC pellets. in the official method, a sample is digested with H2SO4, taken up in HCl, and evaporated to dryness on a water bath, then measured by atomic absorption spectrometry (AAS) or inductively coupled plasma-optical emission spectrometry (ICP-OES). Statistical treatment revealed that the trueness, repeatability (RSDr) and reproducibility (RSDr) were 86-95%, 3.1-9.4% and 8.6-22.1%, respectively. The values of the performance parameters fulfilled the requirements , and the performances met the test specifications. The combination of evaporation to dryness on a hot plate and measurement by AAS or ICP-OES is applicable as an alternative method. However, the trueness and RSDr were inferior to those of the official method. The performance parameters obtained by using the microwave digestion method (MW method) to prepare test solution were better than those of the official method. Thus, the MW method is available as an alternative method. Induced coupled plasma-mass spectrometry (ICP-MS) is also available as an alternative method. However, it is necessary to ensure complete digestion of the sample.


Assuntos
Cádmio/análise , Utensílios de Alimentação e Culinária , Embalagem de Alimentos , Chumbo/análise , Espectrometria de Massas/métodos , Cloreto de Polivinila/análise , Cloreto de Polivinila/química , Espectrofotometria Atômica/métodos , Cádmio/isolamento & purificação , Chumbo/isolamento & purificação , Micro-Ondas
7.
Anal Chem ; 80(15): 6018-22, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18563914

RESUMO

Real-time imaging of single-molecule fluorescence with a zero-mode waveguide (ZMW) was achieved. With modification of the ZMW geometry, the signal-to-background ratio is twice that obtainable with a conventional ZMW. The improved signal-to-background ratio makes it possible to visualize individual binding-release events between chaperonin GroEL and cochaperonin GroES at a concentration of 5 microM. Two rate constants representing two-timer kinetics in the release of GroES from GroEL were measured with the ZMW, and the measurements agreed well with those made with a total internal reflection fluorescence microscopy. These results indicate that the novel ZMW makes feasible the direct observation of protein-protein interaction at an intracellular concentration in real time.


Assuntos
Microscopia de Fluorescência/métodos , Nanotecnologia/instrumentação , Mapeamento de Interação de Proteínas/métodos , Chaperonina 10 , Chaperonina 60 , Desenho de Equipamento , Nanotecnologia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...