Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med Technol ; 36(4): 213-6, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19008289

RESUMO

UNLABELLED: Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied. METHODS: (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared. RESULTS: The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h. CONCLUSION: The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results.


Assuntos
Armazenamento de Medicamentos/métodos , Seringas , Tecnécio Tc 99m Exametazima/análise , Tecnécio Tc 99m Exametazima/química , Avaliação Pré-Clínica de Medicamentos , Estabilidade de Medicamentos , Meia-Vida , Compostos Radiofarmacêuticos/análise , Compostos Radiofarmacêuticos/química
2.
Eur J Nucl Med Mol Imaging ; 35(8): 1449-56, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18418591

RESUMO

PURPOSE: Stimulated thyroglobulin (Tg) and (131)I total-body scan (TBS) have been the mainstays of differentiated thyroid carcinoma (DTC), but now diagnostic TBS has been eliminated from some follow-up protocols. Nevertheless, Tg can be negative in the presence of thyroid tissue, and moderately elevated Tg poses management problems. The purpose of this study was to check how many patients have Tg negative but visible thyroid tissue and if diagnostic TBS could be clinically useful. MATERIAL AND METHODS: Retrospective review of 317 exams (stimulated Tg and TBS) of 128 patients with DTC. Patients with high-grade criteria and/or positive autoantibodies are excluded. Tg is considered positive if higher than the sensitivity level of the technique. TBS is positive if thyroid remnant, lymphatic node or metastases are detected. Results are classified in Tg and TBS concordant or discordant. RESULTS: Discordant (131)I TBS and Tg were found in 74/317 studies (23.3%), 48 (65%) being TBS positive and Tg negative. None of 128 patients had a first post-surgery negative scan, but 13 (10%) were Tg negative, even two patients with lymph node uptake. One year after radioiodine treatment, 26 out of 115 patients (initially Tg and TBS concordant positive) showed Tg negative and TBS still positive due to cervical remnants (20 patients), lymph node uptake (one) and metastasis (five); 20 patients remained Tg and TBS positive, but 14 of them only showed thyroid remnants. CONCLUSIONS: We propose to perform periodic diagnostic TBS to improve Tg specificity, at least while neck thyroid activity is detected, even if Tg is negative.


Assuntos
Radioisótopos do Iodo , Tireoglobulina/sangue , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/cirurgia , Imagem Corporal Total/métodos , Adolescente , Adulto , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Glândula Tireoide/metabolismo , Neoplasias da Glândula Tireoide/sangue , Tireoidectomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...