Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Sci Technol ; 55(3): 1852-1863, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33476134

RESUMO

Exposure to bioaerosols has been implicated in adverse respiratory symptoms, infectious diseases, and bioterrorism. Although these particles have been measured within residential and occupational settings in multiple studies, the deposition of bioaerosol particles within the human respiratory system has been only minimally explored. This paper uses real-world environmental measurement data of total fungal spores using Air-o-Cell cassettes in 16 different apartments and residents' physiological data in those apartments to predict respiratory deposition of the spores. The airborne spore concentrations were measured during the spring, summer, and fall. The respiratory deposition of five most prevalent spore genera-Ascospores, Aspergillus, Basidiospores, Cladosporium, and Myxomycetes-was predicted using three empirical models: the Multiple Path Particle Dosimetry model, using both the Yeh and age-specific versions, and the Bioaerosol Adaptation of the International Committee on Radiological Protection's Lung deposition model. The predicted total deposited number of spores was highest for Ascospores and Cladosporium. While the majority of spores deposit were in the extrathoracic region, there is a significant deposition for both Aspergillus and Cladosporium in the alveolar region, potentially leading to the development of aspergillosis or allergic asthma. Although the dose-response relationship is unknown, the estimate of the actual spore deposition could be the first step in determining such a relationship.


Assuntos
Microbiologia do Ar , Cladosporium , Aspergillus , Monitoramento Ambiental , Humanos , Pulmão , Estações do Ano , Esporos Fúngicos
2.
Indoor Air ; 31(2): 502-523, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32931080

RESUMO

Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building ventilation system types and environmental parameters. A total of 409 indoor and 86 outdoor samples were taken. Eighty-five percent of investigated apartments had indoor-outdoor (I/O) ratios of culturable fungi below 1, suggesting minimal indoor sources of fungi. In contrast, 56% of the apartments had I/O ratios for culturable bacteria above 1, indicating the prominence of indoor sources of bacteria. Culturable fungi I/O ratios in apartments serviced by central heating, ventilation, and air-conditioning (HVAC) system were lower than those in apartments with window AC. The type of ventilation system did not have a significant effect on the presence of indoor culturable bacteria. A significant positive association was determined between indoor dew point (DP) levels and indoor culturable fungi (P < .001) and bacteria (P < .001), regardless of ventilation type. Also, residents in apartments with central HVAC did not experience extreme DP values. We conclude that building ventilation systems, seasonality, and indoor sources are major factors affecting indoor bioaerosol levels in residential buildings.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados , Monitoramento Ambiental , Ar Condicionado , Filtros de Ar , Bactérias , Fungos , Calefação , Habitação , Humanos , Material Particulado , Estações do Ano , Ventilação
3.
J Environ Public Health ; 2016: 3985498, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27382374

RESUMO

Objectives. Worldwide, over 200 million children are involved in child labor, with another 20 million children subjected to forced labor, leading to acute and chronic exposures resulting in safety and health (S&H) risks, plus removal from formal education and play. This review summarized S&H issues in child labor, including forced or indentured domestic labor as other sectors of child labor. Specifically, we focused on exposures leading to S&H risks. Methods. We used PubMed, Scopus, Science Direct, and Google Scholar. References were in English, published in 1990-2015, and included data focused on exposures and S&H concerns of child labor. Results. Seventy-six journal articles were identified, 67 met criteria, 57 focused on individual countries, and 10 focused on data from multiple countries (comparing 3-83 countries). Major themes of concern were physical exposures including ergonomic hazards, chemical exposure hazards, and missed education. Childhood labor, especially forced, exploitative labor, created a significant burden on child development, welfare, and S&H. Conclusions. More field researche data emphasizing longitudinal quantitative effects of exposures and S&H risks are needed. Findings warranted developing policies and educational interventions with proper monitoring and evaluation data collection, plus multiple governmental, international organization and global economic reform efforts, particularly in lower-income, less developed countries.


Assuntos
Países em Desenvolvimento/estatística & dados numéricos , Emprego/estatística & dados numéricos , Saúde Pública/estatística & dados numéricos , Segurança/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Humanos , Exposição Ocupacional
4.
J Air Waste Manag Assoc ; 66(11): 1109-1120, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27333205

RESUMO

This study used several real-time and filter-based aerosol instruments to measure PM2.5 levels in a high-rise residential green building in the Northeastern US and compared performance of those instruments. PM2.5 24-hr average concentrations were determined using a Personal Modular Impactor (PMI) with 2.5 µm cut (SKC Inc., Eighty Four, PA) and a direct reading pDR-1500 (Thermo Scientific, Franklin, MA) as well as its filter. 1-hr average PM2.5 concentrations were measured in the same apartments with an Aerotrak Optical Particle Counter (OPC) (model 8220, TSI, Inc., Shoreview, MN) and a DustTrak DRX mass monitor (model 8534, TSI, Inc., Shoreview, MN). OPC and DRX measurements were compared with concurrent 1-hr mass concentration from the pDR-1500. The pDR-1500 direct reading showed approximately 40% higher particle mass concentration compared to its own filter (n = 41), and 25% higher PM2.5 mass concentration compared to the PMI2.5 filter. The pDR-1500 direct reading and PMI2.5 in non-smoking homes (self-reported) were not significantly different (n = 10, R2 = 0.937), while the difference between measurements for smoking homes was 44% (n = 31, R2 = 0.773). Both OPC and DRX data had substantial and significant systematic and proportional biases compared with pDR-1500 readings. However, these methods were highly correlated: R2 = 0.936 for OPC versus pDR-1500 reading and R2 = 0.863 for DRX versus pDR-1500 reading. The data suggest that accuracy of aerosol mass concentrations from direct-reading instruments in indoor environments depends on the instrument, and that correction factors can be used to reduce biases of these real-time monitors in residential green buildings with similar aerosol properties. IMPLICATIONS: This study used several real-time and filter-based aerosol instruments to measure PM2.5 levels in a high-rise residential green building in the northeastern United States and compared performance of those instruments. The data show that while the use of real-time monitors is convenient for measurement of airborne PM at short time scales, the accuracy of those monitors depends on a particular instrument. Bias correction factors identified in this paper could provide guidance for other studies using direct-reading instruments to measure PM concentrations.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Material Particulado/análise , Aerossóis/análise , Habitação , Mid-Atlantic Region , Tamanho da Partícula
5.
Artigo em Inglês | MEDLINE | ID: mdl-26805862

RESUMO

There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m³) than in Building L (37 µg/m³); I/O was higher in Building E (1.3-2.0) than in Building L (0.5-0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents' exposure to PM in residential green buildings.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Planejamento Ambiental/estatística & dados numéricos , Habitação , Material Particulado/análise , Ventilação/estatística & dados numéricos , New York
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...