RESUMO
OBJECTIVES: The authors sought to study the safety and efficacy of the MANTA Vascular Closure Device (VCD), a novel collagen-based technology dedicated to closure of large-bore arteriotomies. BACKGROUND: Novel transfemoral therapeutic interventions requiring large-bore catheters have become valid minimally invasive options but have inherent access management challenges. To date, no dedicated vascular closure devices exist for large arteriotomies. METHODS: A prospective, single-arm clinical investigation enrolling patients who underwent elective percutaneous interventions with large-bore catheters and planned percutaneous arteriotomy closure in 3 European institutions. RESULTS: A total of 50 patients with a mean age of 79.5 ± 8.3 years underwent high-risk percutaneous coronary intervention, balloon aortic valvuloplasty, or transcatheter aortic valve replacement with large-bore catheters sized 12-F to 19-F. MANTA closure was performed by 9 different operators. The 14-F MANTA VCD was deployed in one-third of the overall cohort (16 of 50, 32%), and the 18-F MANTA VCD in the remainder. The MANTA VCD was deployed successfully in all patients. The mean time to hemostasis was 2 min, 23 s. One patient had a major vascular and major bleeding complication with prolonged femoral bleeding that was successfully treated with a covered stent and eventual surgical repair. There were no other access site-related complications. CONCLUSIONS: This first multicenter experience demonstrates rapid and reliable hemostasis and low complication rates with the use of the plug-based MANTA VCD for large-bore arteriotomy closure.
Assuntos
Cateterismo Periférico/instrumentação , Artéria Femoral , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Dispositivos de Acesso Vascular , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Angiografia por Tomografia Computadorizada , Desenho de Equipamento , Europa (Continente) , Feminino , Artéria Femoral/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Masculino , Estudos Prospectivos , Punções , Fatores de Tempo , Resultado do Tratamento , UltrassonografiaRESUMO
Catheter-based interventions have become a less invasive alternative to conventional surgical techniques for a wide array of cardiovascular diseases but often create large arteriotomies. A completely percutaneous technique is attractive as it may reduce the overall complication rate and procedure time. Currently, large bore arteriotomy closure relies on suture-based techniques. Access-site complications are not uncommon and often seem related to closure device failure. The MANTA VCD is a novel collagen-based closure device that specifically targets arteriotomies between 10 and 22 Fr. This technical report discusses the MANTA design concept, practical instructions for use and preliminary clinical experience.