Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Oral Sci ; 62(3): 308-313, 2020 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-32522911

RESUMO

Guided bone regeneration (GBR) is an effective alveolar ridge reconstruction technique used before or at implant placement. The combination of various barrier membranes and bone substitutes has been employed. This study aimed to perform a preliminarily evaluation of the safety and performance of a new nonabsorbable bi-layered porous polyethylene (PPE) membrane, in combination with a freeze-dried cortical bone allograft in posterior mandibular ridge augmentation. Fifteen adults who had combined posterior mandibular defects were included for ridge augmentation via GBR using PPE membrane and allograft before implant placement. The keratinized mucosa width (KW), ridge width (RW), ridge height (RH), distance from measurement matrix to bone (DMB), and horizontal alveolar width at 14.0 mm apical to the occlusal plane (HAW) were clinically measured at 15 intended implant sites before and after the augmentation. Fifteen biopsy specimens were harvested at the implant sites for histological analysis. All the subjects completed the whole study. The KW and RH showed minor gains by 0.2 ± 1.4 mm and 0.9 ± 2.3 mm respectively; however, no statistically significant differences were found between, before, and after the augmentation (P > 0.05). In contrast, the RW and HAW significantly increased by 4.8 ± 1.6 mm and 2.3 ± 1.7 mm, respectively, (P ≤ 0.001), while DMB significantly decreased by 1.0 ± 0.8 mm after treatment (P < 0.001). Histological analysis revealed that allograft underwent active bone remodeling. The PPE membrane was adequately safe and efficient to use with allograft in GBR for the reconstruction of combined ridge defects. Although some complications were observed, these were manageable and subsequently lead to successful implant placement for all the subjects. However, further randomized controlled trials are still needed to confirm these findings.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Regeneração Óssea , Transplante Ósseo , Implantação Dentária Endóssea , Polietileno , Porosidade
2.
J Periodontal Implant Sci ; 50(2): 106-120, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32395389

RESUMO

PURPOSE: A new form of porous polyethylene, characterized by higher porosity and pore interconnectivity, was developed for use as a tissue-integrated implant. This study evaluated the effectiveness of porous polyethylene blocks used as an onlay bone graft in rabbit mandible in terms of tissue reaction, bone ingrowth, fibrovascularization, and graft-bone interfacial integrity. METHODS: Twelve New Zealand white rabbits were randomized into 3 treatment groups according to the study period (4, 12, or 24 weeks). Cylindrical specimens measuring 5 mm in diameter and 4.5 mm in thickness were placed directly on the body of the mandible without bone bed decortication, fixed in place with a titanium screw, and covered with a collagen membrane. Histologic and histomorphometric analyses were done using hematoxylin and eosin-stained bone slices. Interfacial shear strength was tested to quantify graft-bone interfacial integrity. RESULTS: The porous polyethylene graft was observed to integrate with the mandibular bone and exhibited tissue-bridge connections. At all postoperative time points, it was noted that the host tissues had grown deep into the pores of the porous polyethylene in the direction from the interface to the center of the graft. Both fibrovascular tissue and bone were found within the pores, but most bone ingrowth was observed at the graft-mandibular bone interface. Bone ingrowth depth and interfacial shear strength were in the range of 2.76-3.89 mm and 1.11-1.43 MPa, respectively. No significant differences among post-implantation time points were found for tissue ingrowth percentage and interfacial shear strength (P>0.05). CONCLUSIONS: Within the limits of the study, the present study revealed that the new porous polyethylene did not provoke any adverse systemic reactions. The material promoted fibrovascularization and displayed osteoconductive and osteogenic properties within and outside the contact interface. Stable interfacial integration between the graft and bone also took place.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...