Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Sci (Basel) ; 166(1)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38725869

RESUMO

Radiomics involves the extraction of information from medical images that are not visible to the human eye. There is evidence that these features can be used for treatment stratification and outcome prediction. However, there is much discussion about the reproducibility of results between different studies. This paper studies the reproducibility of CT texture features used in radiomics, comparing two feature extraction implementations, namely the MATLAB toolkit and Pyradiomics, when applied to independent datasets of CT scans of patients: (i) the open access RIDER dataset containing a set of repeat CT scans taken 15 min apart for 31 patients (RIDER Scan 1 and Scan 2, respectively) treated for lung cancer; and (ii) the open access HN1 dataset containing 137 patients treated for head and neck cancer. Gross tumor volume (GTV), manually outlined by an experienced observer available on both datasets, was used. The 43 common radiomics features available in MATLAB and Pyradiomics were calculated using two intensity-level quantization methods with and without an intensity threshold. Cases were ranked for each feature for all combinations of quantization parameters, and the Spearman's rank coefficient, rs, calculated. Reproducibility was defined when a highly correlated feature in the RIDER dataset also correlated highly in the HN1 dataset, and vice versa. A total of 29 out of the 43 reported stable features were found to be highly reproducible between MATLAB and Pyradiomics implementations, having a consistently high correlation in rank ordering for RIDER Scan 1 and RIDER Scan 2 (rs > 0.8). 18/43 reported features were common in the RIDER and HN1 datasets, suggesting they may be agnostic to disease site. Useful radiomics features should be selected based on reproducibility. This study identified a set of features that meet this requirement and validated the methodology for evaluating reproducibility between datasets.

2.
Clin Transl Radiat Oncol ; 40: 100596, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36910024

RESUMO

Background and purpose: Adaptive radiotherapy (ART) in locally advanced cervical cancer (LACC) has shown promising outcomes. This study investigated the feasibility of cone-beam computed tomography (CBCT)-guided online ART (oART) for the treatment of LACC. Material and methods: The quality of the automated radiotherapy treatment plans and artificial intelligence (AI)-driven contour delineation for LACC on a novel CBCT-guided oART system were assessed. Dosimetric analysis of 200 simulated oART sessions were compared with standard treatment. Feasibility of oART was assessed from the delivery of 132 oART fractions for the first five clinical LACC patients. The simulated and live oART sessions compared a fixed planning target volume (PTV) margin of 1.5 cm around the uterus-cervix clinical target volume (CTV) with an internal target volume-based approach. Workflow timing measurements were recorded. Results: The automatically-generated 12-field intensity-modulated radiotherapy plans were comparable to manually generated plans. The AI-driven organ-at-risk (OAR) contouring was acceptable requiring, on average, 12.3 min to edit, with the bowel performing least well and rated as unacceptable in 16 % of cases. The treated patients demonstrated a mean PTV D98% (+/-SD) of 96.7 (+/- 0.2)% for the adapted plans and 94.9 (+/- 3.7)% for the non-adapted scheduled plans (p<10-5). The D2cc (+/-SD) for the bowel, bladder and rectum were reduced by 0.07 (+/- 0.03)Gy, 0.04 (+/-0.05)Gy and 0.04 (+/-0.03)Gy per fraction respectively with the adapted plan (p <10-5). In the live.setting, the mean oART session (+/-SD) from CBCT acquisition to beam-on was 29 +/- 5 (range 21-44) minutes. Conclusion: CBCT-guided oART was shown to be feasible with dosimetric benefits for patients with LACC. Further work to analyse potential reductions in PTV margins is ongoing.

3.
Med Dosim ; 38(2): 165-70, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23265938

RESUMO

Dose distributions for prostate radiotherapy are difficult to predict in patients with bilateral hip prostheses in situ, due to image distortions and difficulty in dose calculation. The feasibility of delivering curative doses to prostate using intensity-modulated radiotherapy (IMRT) in patients with bilateral hip prostheses was evaluated. Planning target volumes for prostate only (PTV1) and pelvic nodes (PTV2) were generated from data on 5 patients. PTV1 and PTV2 dose prescriptions were 70 Gy and 60 Gy, respectively, in 35 fractions, and an additional nodal boost of 65 Gy was added for 1 plan. Rectum, bladder, and bowel were also delineated. Beam angles and segments were chosen to best avoid entering through the prostheses. Dose-volume data were assessed with respect to clinical objectives. The plans achieved the required prescription doses to the PTVs. Five-field IMRT plans were adequate for patients with relatively small prostheses (head volumes<60 cm(3)) but 7-field plans were required for patients with larger prostheses. Bowel and bladder doses were clinically acceptable for all patients. Rectal doses were deemed clinically acceptable, although the V50Gy objective was not met for 4/5 patients. We describe an IMRT solution for patients with bilateral hip prostheses of varying size and shape, requiring either localized or whole pelvic radiotherapy for prostate cancer.


Assuntos
Prótese de Quadril , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Humanos , Metástase Linfática , Masculino , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...