Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 11(11)2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34829354

RESUMO

Thirty-one consecutive patients were included in this study who were planned for parathyroidectomy due to primary hyperparathyroidism. They were studied with US, 4D-CT and dual-phase scintigraphy including SPECT/CT, and possible adenomas were identified in each imaging modality. Imaging data were quantified with US, CT and SPECT. Parathyroidectomies were performed as minimally invasive according to preoperative imaging findings. A total of 16 adenomas were found in 15 patients, and the surgery was negative in four patients. The imaging results were compared with each other and correlated to histology findings and blood biochemistry (S-Ca and P-PTH). Quantitative SPECT found a strong correlation between the quantification methods-Conjugate Gradient with Attenuation and Scatter Correction with a zone map (CGZAS) and Conjugate Gradient with Attenuation and Scatter Correction (CGAS)-measured as SUVmax and kBq/mL. However, a statistically significant correlation between the quantitative parameters (CGZAS and CGAS) and serum biomarkers (S-PTH and S-Ca) was not observed. The sensitivities of the imaging methods were calculated using histopathology as a gold standard. SPECT/CT demonstrated 93% sensitivity, 4D-CT 93% sensitivity and ultrasonography 73% sensitivity. The imaging methods were compared with each other using parathyroid regions because findings and locations varied between the modalities. Our prospective study supports that quantitative SPECT/CT is useful for presurgical assessment of primary hyperparathyroidism.

2.
J Nucl Cardiol ; 23(4): 657-67, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27033352

RESUMO

BACKGROUND: Recent technological advances in myocardial perfusion imaging may warrant the use of lower injected activity. We evaluated whether quantitative measures of stress myocardial perfusion defects using Tc-99m sestamibi and low-energy high-resolution (LEHR) collimators are equivalent to lower dose SPECT-CT with cardiac multifocal collimators and software (IQ·SPECT). METHODS: 93 patients underwent one-day rest-stress gated SPECT-CT. Following conventional rest imaging, 925-1100 MBq (25-30 mCi) of Tc-99m sestamibi was injected during stress testing. Stress SPECT-CT images were acquired two ways: with LEHR (13 minutes) and IQ·SPECT (7 minutes). Low-dose IQ·SPECT stress was simulated by subsampling the full-dose data to half-, quarter-, and eighth-count levels. Abnormalities were quantified using the total perfusion deficit (TPD) score and dose-specific databases. RESULTS: The mean ± SD of the differences between LEHR and IQ·SPECT TPD scores were -1.01 ± 5.36%, -0.10 ± 5.81%, 1.78 ± 4.81%, and 1.75 ± 6.05% at full, half, quarter, and eighth doses, respectively. Differences were statistically significant for quarter and eighth doses. Correlation between LEHR and IQ·SPECT was excellent at all doses (R ≥ 0.93). Bland-Altman plots demonstrated minimal bias. CONCLUSIONS: With IQ·SPECT, quantitative stress SPECT-CT imaging is possible with half of the standard injected activity in half the time.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Teste de Esforço/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Exposição à Radiação/análise , Proteção Radiológica/instrumentação , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tecnécio Tc 99m Sestamibi , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...